0.4KW~800KW CMAX Control AC Motor Inverter Frequency

Ref Price:
Loading Port:
China Main Port
Payment Terms:
TT or LC
Min Order Qty:
1 pc pc
Supply Capability:
8000 pcs per month pc/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Description Of 0.4KW~800KW CMAX Control AC Motor Inverter Frequency

0.4KW~800KW CMAX Control AC Motor Inverter Frequency is a high-quality, multi-function, low-noise variable frequency drive which is designed, developed and manufactured according to international standards. It can meet different needs of industrial conditions.The inverter applies advanced control technology of space voltage vector PWM, with functions of constant voltage control, power-off restart, dead zone compensation, automatic torque compensation, online modification parameter, high-speed impulse input, simple PLC and traverse

 

Features Of 0.4KW~800KW CMAX Control AC Motor Inverter Frequency

1).Adopts 16 bit microprocessor, sine wave PWM control

2).Automatic torque ascension and automatic sliding compensation function

3).Output frequency 0.1-400 Hz

4).8 period of speed setting and 7 period can be running the program

5).Low noise, carrier frequency can from 1 kHz-15 kHz adjustment

6).Two paragraphs Acceleration and deceleration time and two segments of the S Curve slow and deceleration

7).Simulation frequency set acceptable 0-10 VDC, 4-20 mA

8).The built-in serial communication interface RS-485(baud rate can reach 38400)

9).Save energy running and automatic voltage stabilizing section function (AVR)

10).Adjustable V/F curve Acceleration and automatic and deceleration function

11).Simple vector control and built-in PID control, and the simple positioning function

12).Sleep/wake up function and zero velocity keep function

 

Structure Of 0.4KW~800KW CMAX Control AC Motor Inverter Frequency

0.4KW~800KW CMAX Control AC Motor Inverter Frequency

Application Of 0.4KW~800KW CMAX Control AC Motor Inverter Frequency

★Textile: coarse spinner, spinning frame, wrap-knitting machine, loom, knitting machine, silk-spinning machine, etc.

★Plastic: extruder, hauling machine, decorating machine, etc.

★Pharmacy: mixer, roaster, etc.

★Woodworking: engraving machine, sander, veneer peeling lathe, etc.

★Papermaking: single type papermaking machine, etc.

★Machine tool: non-core grinding machine, optical lens grinding machine, cutting mill, etc.

★Printing: cloth-washing machine, dye vat, etc.

★Cement: feeder, air blower, rotary furnace, mixer, crusher, etc

★Fan and pump: kinds of fans, blowers and pumps

0.4KW~800KW CMAX Control AC Motor Inverter Frequency

 

Performance Of 0.4KW~800KW CMAX Control AC Motor Inverter Frequency

Item Specification
Input Rated voltage T4 series: Three phase 380v, ±15%
Frequency  S/T2 series: Three/single phase 220V, ±15%
50/60Hz  ±5%
Output Voltage T4 series: Three phase 0-380V
Frequency S/T2 series: Three phase 0~220v
0-400Hz
Overload ability 150% rated current for 30s; 180% rated current for 1s;
Dissipation Cooling type  Forced Cooling
Temperature protection  Heatsink temperature >85℃ trip protection against overheat
Fan control Heatsink temperature> 50℃, fan forced operation, frequency inverter continue work
Control Control mode Open-loop vector control, V/F control
Performance Start torque Open-loop vector control: 0.5Hz 180%; 
VF control: 0.5Hz 150%
Speed range Open-loop vector control:1:150; 
VF control:1:100
Speed control precision Open-loop vector control: ±0.2%; 
VF control:±0.5%
Function Channel of operation command Keyboard control,terminal control,communication control
Start mode Direct start, DC injection braking before start, speed tracking before start
DC injection braking Start DC injection braking, stop DC injection braking
Dynamic braking Built-in braking unit
Frequency source choice Keyboard digital frequency setting, analog AVI setting
PID control setting, telecommunications setting
Frequency resolution Keypad setting:0.01Hz; Analog setting: 0.1%
Carrier frequency 1Khz~12Khz,
Acc/Dec time 0.1~6000.0s or 0.01~600.00s
Signal Analog input AVI:0~10V
ACI:4~20mA 
Keyboard potentiometer input: 0~10V
Analog output AFM:0~10V or 0~20mA, Select through JP1 jumper
Digital input A total of 28 kinds of function could be selected from S0 ~S5.
Digital output 1 channel open collector output(MO1-MCM)
1 channel relay output( TA-TC normally open, TB-TC normally closed;
Communication Port Communication protocol Based on RS485 hardware, support standard MODBUS protocol. 
Display Functions Four digital tube display Can monitor the operation state of frequency inverter flexibly and conveniently.
Installation                                 Humidity Less than 90%RH
condensation
Vibration Less than0.6G
Elevation 0~1000m, reduce the rated specification 10% when lift 1000m for each. 
Storage temperature -20~60℃          
Structure Defend degree IP20

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Inverter 0.2KW, the motor speed requirements down to 4 turn, the motor pole 4 pole. Can the drive drive the motor?
Can, but this is a test product, the application does not try!
Q:22kw.2 pole fan can use Fuji inverter?
Fan with Fuji? Money more people silly ... no comment ..
Q:Why the number of motor poles increased, the inverter capacity will increase
The power of the three-phase motor is equal to the root number of 3 times the line current and the line voltage of the product again good with the power factor. Can also be 3 times the phase current and phase voltage of the good product and then good to power factor. The frequency converter should match the rated current of the motor, not the power of the motor.
Q:Pump frequency converter instantaneous restart and restart the problem
Speed tracking start, with them better. Speed search time is less than the free downtime, not too small too much, will be over-voltage protection. I do not understand and contact me. Your inverter voltage level, manufacturers.
Q:Is the laptop power adapter long-haul?
Oh, the power adapter is a transformer, we use the electricity is 220, after it will be converted into a suitable computer voltage, or notebook can not withstand 220V, so as long as the power inside the transformer will work, If you do not have a computer, it is best to unplug the plug on the power outlet, even if the computer has to pull out from the outlet, or will have an impact on the life of the adapter.
Q:How does the variable frequency motor output torque at very low frequencies?
Low frequency, the motor torque is relatively low, generally VF inverter performance is good or bad, the price level reflected in this time. But there is torque to enhance the function, it will not move without moving. If no load can not start, check the motor card and other mechanical problems such as whether there is a problem.
Q:Yaskawa inverter reported base blockade what is the reason?
Yasukawa compared garbage on the signal board on the small line of poor oxidation, and get like, this is a weak signal, and safety relays connected, do not use high-grade security circuit with a small line short, Yasukawa A 1000 factory is short for a long time after the oxidation of the base blockade
Q:Laptop adapter heat
In fact, as long as the power adapter temperature is within the design range, that is, the temperature in the normal range, the general is not dangerous! So why is the power supply hot? What kind of temperature range is the normal range? Switching power supply conversion efficiency can only reach 75% -85% or so. The answer is here. Switching power supply conversion efficiency is high enough, it is still difficult to find a better way to convert. Switching power supply in the voltage conversion, a part of the energy loss, in addition to a small part of the loss in the form of waves, the majority of the way out of the heat. Switching power supply power is missing, the loss of energy is also missing, the power of the heat is also large. This is why the desktop power supply to add a fan for cooling reasons. We may wish to count, a 100W switching power supply, in the use of how much energy loss in the above!
Q:What is the base blockade in the drive?
After the base is blocked, the power tube is fully closed to protect the power tube.
Q:2 pole 0.75 kW motor can increase the speed through the inverter?
2-pole motor speed of about 2900 r / min or so, 4-pole motor speed of about 1400 r / min or so, which are in the case of 50HZ,
We are a professional inverter manufacturer integrating R&D, production and sales. With an experienced R&D and production team and sophisticated production lines, our company has become a domestic first-class inverter manufacturer by virtue of advanced technology, excellent quality, scientific management and perfect service

1. Manufacturer Overview

Location Zibo, China
Year Established 2004
Annual Output Value Below US$1 Million
Main Markets Middle-East America; Mid East; Northern Europ; Africa; Southeast Asia
Company Certifications CE;ISO

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port Qingdao
Export Percentage 1% - 10%
No.of Employees in Trade Department 500-999 People
Language Spoken: English; Chinese
b)Factory Information  
Factory Size: Above 50,000 square meters
No. of Production Lines Above 8
Contract Manufacturing
Product Price Range High; Average