Inverter 1500 Watt/ Built-in Battery Charger 12V

Ref Price:
Loading Port:
China Main Port
Payment Terms:
TT or LC
Min Order Qty:
100 Pieces pc
Supply Capability:
50000 Pieces per Month pc/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

1.1500W Inverter Built-in Battery charger

2.Integrated with 20A charger

3.Fashional outlook

4.Satisfied life-span

5.Capacity: 1500W

6.super wide input voltage: 170V---270VAC.

7.completely controlled by CPU.

8.protection against output short-circuit; Against overload, and when you throw off its load,it will turn on the unit automatically.

9.functions that when the AC comes in, it will start the unit automatically.

10.with charger built-in, its charging current is 20A.

11.different DC volage: 12V, 24V, 36V, 48V, 96V, 110V,192V, 240V for optional

12.output modified sine wave: 220V+-3%. 

 

 

Characteristics of safety:

1. Overload protection, the power will be automatically cut off.

2. The integral fuse provides the safety guarantee.

3. Low voltage warning, the power will be automatically cut off.

4. Overvoltage protection, the power will be automatically cut off.

5. Overhumidity protection, the power will be automatically cut off.

6. Short circuit protection, the power will be automatically cut off.

 

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Speed of 3000 r / min three-phase motor how to change its speed
The key lies in two points: 1, you ask the variable range is how much? 2, your motor had a few qualifying? If your motor is 6 outlet, and you only need to speed, plus your motor is also an asynchronous motor, and you do not have the requirements of the load; then congratulations, you can achieve "speed" You just put the motor wiring way to do a △ - Y or Y - △ conversion can be achieved. If the above conditions you have one or two can not meet, then your best way is to buy a drive to achieve the variable speed. Of course, you can also make some changes to the winding to achieve the so-called single-winding multi-speed operation (this change, but the need for a certain technical content).
Q:Old printing machine transformation, 37KW6 polar frequency motor with brake, inverter 55KW, now found running,
It should be the inverter problem, I have encountered before, followed by the inverter upgrade was resolved. Is to replace a set of power board, power board, CPU board.
Q:The inverter flat rate transferred to 29, on the submersible pump to burn the coil ?!
The following describes the selection of the inverter Note: The inverter selection is mainly driven by the load characteristics and the actual motor current to set, in addition, there are the following precautions. 1, the environment: for some high temperature (higher than 50 degrees), high altitude (more than 1000 meters) of the application, the inverter selection should be appropriate to leave a margin to ensure that the inverter and motor life. 2, distance: the location of the inverter installation and drive the distance between the motor more than 50 meters, the frequency changer selection should cooperate with the reactor to reduce the carrier frequency. 3, a drag: a drive drag more than one motor, if the middle of the cable is too long, universal inverter selection will enlarge the use of a file, and each machine should be installed behind the fuse.
Q:Three sets of batteries (540V) DC power supply U / f inverter.
It is estimated that the battery should be string - and - series connection method, and then rectifier part of the converter (which may also be caused by the switch) is actually a series of diodes in series, positive and negative after the reverse is actually the battery is Negative shorts, resulting in burning, as to burn only one of the group of a few cells, it should be string - and - string and that group, because the parallel to bear it double voltage.
Q:My laptop can not use the power adapter, and can only use the battery, how is it ah,
I have encountered the same problem, plug in the adapter, or use the battery power, the battery alarm, not the battery charge, the power adapter can not be used. But the power can charge the battery. If the power adapter alone, one will automatically shut down. Measure the adapter voltage normally. And then to get the computer city maintenance department, gymnastics, it is a simple question, the original power line in the circuit board on the solder joints are loose, that is, Weld, resulting in insufficient current, no wonder, off the machine can charge, boot can not charge, It shuts down. Spent 100 yuan. Business really black. I saw the repair. On the welding a few times OK. No wonder, once I suddenly shot about, the adapter can be used. Later, how to shoot not work. However, although spent 100, but my computer's heat silicone grease for the whole, the computer CPU temperature is not so high before. The beginning of the maintenance staff said that the power management chip may be broken, if the bad to more than 100, then, no bad, just contact the problem, welding also received me 100, really depressed. In fact, you can say good, if the contact problem, certainly below 100.
Q:Is the laptop power adapter long-haul?
This is not good, If you need to shut down, then it is recommended that the power adapter plug from the board to pull down. Because if only pull the adapter and the computer plug so that the adapter will still have the internal current through, hear the small sound is actually the sound of the current. So it is recommended that the power adapter from the outlet on the unplugged, and the computer connected to the one do not have to pull, so that will not cause the power adapter power and convenient computer to open.
Q:What are the differences and links between the soft starters and the frequency converters, and their respective principles and uses?
Soft starters and frequency converters are two completely different uses of the product. The frequency converter is used for the need for speed control where the output not only changes the voltage but also changes the frequency; the soft starter is actually a voltage regulator for the motor to start when the output only changes the voltage and does not change the frequency. The frequency converter has all the soft starter functions, but its price is much more expensive than the soft starter, the structure is much more complex. Soft starter (soft starter) is a set of motor soft start, soft stop, light load energy saving and a variety of protection functions in one of the new motor control device, known as the Soft Starter abroad. The softener uses a three-phase anti-parallel thyristor as a voltage regulator, which connects it between the power supply and the motor stator. This circuit, such as three-phase full-bridge rectifier circuit. When using the soft starter to start the motor, the output voltage of the thyristor gradually increases, the motor gradually accelerates until the thyristor is fully conductive, the motor works at the mechanical characteristics of the rated voltage, smooth start, reduce the starting current and avoid starting the overcurrent trip. When the motor reaches the rated speed, the start-up process ends, the soft starter automatically uses the bypass contactor to replace the completed thyristor, providing the rated voltage for the normal operation of the motor to reduce the heat loss of the thyristor and prolong the service life of the soft starter , To improve its efficiency, but also to avoid the harmonic pollution to the grid. Soft starter also provides soft stop function, soft stop and soft start the process of reverse, the voltage gradually reduced, the number of revolutions gradually reduced to zero, to avoid free-wheeling caused by the impact of torque. How the frequency converter works
Q:Laptop power supply 20V 3.5A can use 20V 4.5A power adapter Mody, what impact?
The current will be great ... ... a long time on the bad
Q:Do not the laptop directly connected to the power adapter?
"Notebook do not power adapter", can only use the internal lithium battery power supply work. It can not directly use 220V AC power supply for it. 1, because the notebook product design power supply standard, is to use the matching power adapter power supply. That is, the power adapter will 220V civilian AC, rectifier filter, and then converted to low-voltage 19V DC, for the notebook to provide power supply;
Q:The Schneider inverter reports the nlp command
1, the inverter control circuit with an external 24V power supply, the main circuit did not power 2, PO and PA between the short film can not cause this failure.
Our products comply with international quality standards and are greatly appreciated in a variety of different markets throughout the world. Our well-equipped facilities and excellent quality control throughout all stages of production enable us to guarantee total customer satisfaction. Besides, we have attained ISO9001 and ISO14001 certifications.

1. Manufacturer Overview

Location Guangdong,China (Mainland)
Year Established 2008
Annual Output Value US$5 Million - US$10 Million
Main Markets North America; South America; Eastern Europe; Southeast Asia; Oceania; Western Europe
Company Certifications ISO 9001:2000

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage 71% - 80%
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size: 1,000-3,000 square meters
No. of Production Lines 6
Contract Manufacturing OEM Service Offered
Product Price Range