• Soundproof Genset Diesel Generator , 50kw - 900kw Emergency Generator System 1
  • Soundproof Genset Diesel Generator , 50kw - 900kw Emergency Generator System 2
Soundproof Genset Diesel Generator , 50kw - 900kw Emergency Generator

Soundproof Genset Diesel Generator , 50kw - 900kw Emergency Generator

Ref Price:
get latest price
Loading Port:
Guangzhou
Payment Terms:
TT OR LC
Min Order Qty:
1 unit
Supply Capability:
1500 unit/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Soundproof Genset Diesel Generator , 50kw - 900kw Emergency Generator

 

 

Quick Detail:

1.UK Perkins water cooled engine:403-11G,1103A-33G,1006-6TAG

2.AC Alternator Brand:stamford,leroy somer,marathon

3.ac brushless 4 poles ,self-excited  alternator

4.deepsea,smartgen Digital auto-start panel

 

 

Specifications:

 

Genset Model

Prime Power

Standby Power

Engine

Fuel Consumption

Cylinder No.

Displacement

Bore X Stroke

KW

KVA

KW

KVA

(g/kwh)

 (L )

(mm)

GNRP10

7

9

8

10

403D-11

≤252

3

1.131

77*81

GNRP15

10

13

12

15

403D-15

≤264

3

1.496

84*94

GNRP23

16

20

18

23

404D-22

≤243

4

2.216

84*100

GNRP33

24

30

26

33

1103A-33G

≤210

3

3.3

105*127

GNRP50

36

45

40

50

1103A-33TG1

≤212

3

3.3

105*127

GNRP65

48

60

52

65

1103A-33TG2

≤211

3

3.3

105*127

GNRP73

52

65

58

73

1104A-44TG1

≤207

4

4.4

105*127

GNRP88

64

80

70

88

1104A-44TG2

≤213

4

4.4

105*127

GNRP103

75

94

82

103

1006TG1A

≤210

6

5.99

100*127

GNRP150

110

138

120

150

1006TAG

≤205

6

5.99

100*127

GNRP165

120

150

132

165

1006TAG2

≤205

6

5.99

100*127

GNRP225E

165

206

180

225

1306C-E87TAG3

≤220

6

8.7

117*136

GNRP250E

180

225

200

250

1306C-E87TAG4

≤219

6

8.7

117*136

GNRP259E

188

235

207

259

1306C-E87TAG5

≤221

6

8.7

117*136

GNRP275E

200

250

220

275

1306C-E87TAG6

≤223

6

8.7

117*136

GNRP344E

250

313

275

344

2206C-E13TAG2

≤201

6

14.6

137*165

GNRP388E

280

350

310

388

2206C-E13TAG2

≤198

6

14.6

137*165

GNRP450E

320

400

360

450

2206C-E13TAG3

≤201

6

14.6

137*165

GNRP500E

360

450

400

500

2506C-E15TAG1

≤216

6

15

137*171

GNRP550E

400

500

440

550

2506C-E15TAG2

≤211

6

15

137*171

GNRP625E

450

563

500

625

2806A-E18TAG1A

≤196

6

18.13

145*183

GNRP700E

508

635

560

700

2806A-E18TAG2

≤203

6

18.13

145*183

GNRP800

580

725

640

800

4006-23TAG2A

≤199

6

22.921

160*190

GNRP900

640

800

720

900

4006-23TAG3A

≤200

6

22.921

160*190

GNRP1000

720

900

800

1000

4008-TAG1A

≤206

8

30.561

160*190

GNRP1125

818

1022

900

1125

4008-TAG2A

≤208

8

30.561

160*190

GNRP1375

1000

1250

1100

1375

4012-46TWG2A

≤212

12

45.482

160*190

  

 

  Genset Features:

1. Genuine UK industrial diesel engine

2. Radiator 40°C max, fans are driven by belt, with safety guard

3. Genuine stamford. Leroy somer, marathonm, engga alternator

4. Choice of manual/auto and AMF control panels and protection systems

5. Digital auto-start panel

6. Anti Vibration Suspension Absorber

7. Dry type air filter, fuel filter, oil filter

8. 10-hour operation base tank

9.Mould case circuit breaker

10. 24V DC start motor and storage battery

11. 24V charge alternator

12. 24V batteries, rack and cable

13. Rippl;e flex echaust pipe, exhaust siphon, flange, and muffler

14. Comply with ISO and CE standards

15. All generator sets are gone through rigorous testing before beging released to the market place, including 50% load, 75% load, 100% load and all protection function(over speed stop, high water temperature, low oil pressure, battery charging fail, emergency stop)

 

Engine Features:

1. Genuine UK Perkins industrial diesel engine

2. Multi-cylinder in-line or veer engine, 4-stroke, direct injection

3. Naturally aspirated, turbocharged, water cooled or turbocharged with air intercooler

4. Machinery or electronic governing

5. Fuel injection pump

6. Electric motor starting system

7. Forged steel crankshaft, cast iron cylinder and replaceable wet type cylinder liner

8. Low discharge, and low fuel consumption

9. Installed conveniently and maintain easily

 

Alternator Features:

1. World famous brand AC alternator: Leroy Somer, Stamford, Marathon, ENGGA

2. Brushless, 4 poles, rotation magnet

3. IP21-23(NEMA1) enclose is standard for all industrial alternators

4. H class insulation system

5. AVR self-regulated, voltage regulation rate: ≤±1%

6. Simple installation and maintenance with easy access to terminals, rotating diodes and coupling bolts

7. Wide range of flange adaptors and single bearing disc coupling

8. Radio interference restraining accords with the stipulation of VDE0875-N and ISO8528

9. Moisture proof, sand-proof, dustproof, salt-proof and vibration-proof

 

Digital Control panel

Controller Brand: Smartgen, Deepsea,ComAp

Control Panel: English interface,LED screen and touch buttons.

Main Functions:

1- Display loading power, voltage, currenct, frequency, speed, temperature, oil pressure, running time etc.

2- Warning when low or high voltage, low or high frequency, over current, over or low speed, low or over battery voltage etc.

3- Over load protection, over/under frequency protection, over/under/imbalance voltage protection, and low oil shutdown

 

Soundproof/Silent Box:

1. Excellent ventilation

2. Oil tank mounted on base frame for 12 Hours working

3. Highly Corrosion Resistant construction

4. Excellent Access for Maintenance

5. Security and Safety

6. 1m<80DBA / 7m<70DBA

 

Optional:

1. Trailer type

2. Soundproof / water proof

3. ATS (automatic transfer switch)

4. Parallel system

5. Remote system

 

PMC System:

1. Standard 23 pitch windings avoid excessive neutral current

2. Permanent magnet generator system provides constant excitation under all condition

3. Optional accessories available for easy paralleling with mains or other generators

4. AVR auto voltage regulation, auto exciter, auto adjustment

 

Soundproof Genset Diesel Generator , 50kw - 900kw Emergency Generator

 

 

Q:Can ordinary motors use a frequency converter?
Yes, but there are differences, as follows: Ordinary induction motor can be controlled by frequency conversion, no difference in usage of frequency conversion motor. But because it is designed according to the frequency of labor frequency, the relative frequency conversion machine, the existence efficiency is low, the temperature rises high, the insulation is easy to age, the noise and the vibration, the cooling is different. The detailed analysis is as follows: A normal asynchronous motor cannot fully adapt to the requirements of variable frequency control. The following is the effect of the converter on the motor The efficiency of the motor and the problem of temperature rise Regardless of the type of frequency converter, different levels of harmonic voltage and current are produced in the operation, and the motor is running in the non-sine voltage and the current. The high harmonics will cause the motor stator copper consumption, the rotor copper (aluminum) consumption, the iron consumption and the added loss, most notably the rotor copper (aluminum) consumption. For asynchronous motor is close to the base wave frequency corresponds to the synchronous speed of rotation, therefore, higher harmonic voltage to a larger slip cutting rotor after conducting bar, will produce very big rotor loss. In addition, additional copper consumption due to the skin effect is considered. These losses will make motor extra heat, low efficiency, output power decreases, and such as ordinary three-phase asynchronous motor running in the inverter output non-sinusoidal power supply conditions, the temperature rise to increase 10% - 10%.
Q:Can a converter control a general electric machine
Of course, the converter can control the common asynchronous machine, and the 6 pole is not a problem, the low speed control is above 8HZ
Q:The difference between servo motor and general motor?
The design of an ordinary asynchronous motor is designed by constant frequency constant pressure, and it is not possible to fully adapt to the requirements of variable frequency control. Under the influence of frequency converter for motor 1, the efficiency and the problem of temperature rise of the motor In either in the form of a frequency converter, both in the operation of the different degree of harmonic voltage and current, make the motor in non-sinusoidal voltage, power flow operation. Rejected materials is introduced, at the current widely used sine wave type PWM inverter as an example, the basic is zero, the low-order harmonic larger than the rest of the carrier frequency times the left and right sides of higher harmonic components as: 2 u + 1 (u for modulation ratio). Can lead to higher harmonic motor stator copper loss, rotor copper (aluminum), iron loss and the increase of the additional loss, the most significant is the rotor copper (aluminum) consumption. For asynchronous motor is close to the base wave frequency corresponds to the synchronous speed of rotation, therefore, higher harmonic voltage to a larger slip cutting rotor after conducting bar, will produce very big rotor loss. In addition, additional copper consumption due to the skin effect is considered. These losses will make motor extra heat, low efficiency, output power decreases, and such as ordinary three-phase asynchronous motor running in the inverter output non-sinusoidal power supply conditions, the temperature rise is to increases 10% ~ 20%.
Q:Is the washing machine an ordinary motor or DD converter?
All the shares, after sales, panasonic, didn't come together, But it's hard to say, everything is bad, The individual advised you to buy a cheaper one, I want to tell you a little bit about it. The wave wheel, the drawback, the super waste water, wear the clothes, can't wash the big pieces. Advantages, shorter washing time, better cleaning ratio, 2, drum, shortcomings, can't use washing powder, was leaking bubble in the rinse impurities, washing time, rinse than low, advantages, it does not hurt the clothes, super save water, can wash large appropriately, but clothing thickness distribution well, the price is a relatively expensive To sum up, the house is rich in good clothes to buy the roller, the economic popular clothing is not too high-grade or buy the wave wheel, hehe, Also throw in a word, don't buy too good, life is all about, cheap cheap bad repair, repair threw a don't worry about too expensive, ha ha, the brand is just a symbol,
Q:What is the structural difference between a two-speed motor and a regular motor
Most of speed regulating pole change motor for squirrel-cage rotor motor, its structure is similar to the basic series three-phase asynchronous squirrel cage motor, now the domestic production of two, three, four speed 3 classes. Common asynchronous motor rotor speed formula: n = 60f/p, ordinary motor has only one speed.
Q:The difference between pulse motor and servo motor
The step motor is synchronous motor, which is running in step by step and is open loop. The servo motor is running continuously, with the encoder feedback, it is closed loop.
Q:The difference between brushless dc motor and plain dc motor, where is its advantage
Brushless dc motor consists of motor subject and drive, which is a typical electromechanical integrated product. The stator winding of the motor is a three-phase symmetric star connection, which is similar to the three-phase asynchronous motor. The rotor of the motor is attached to the magnetized permanent magnet, which detects the polarity of the motor rotor and has a position sensor in the motor. Drive consists of power electronic devices and integrated circuit, its function is: accept the motor start, stop, brake signal, to control the motor start, stop, and the brake; To accept the signal of position sensor and the positive and reverse signal to control the flow of the power pipe of the inverter bridge to produce continuous torque. Accept the speed and speed feedback signals to control and adjust the speed. Provide protection and display, etc. Because of brushless dc motor based on self-control type operation, so don't like frequency control of motor speed synchronous motor overload start under plus startup winding on the rotor, also won't generate oscillation and step out when load mutation.
Q:What is the difference between a general motor and a high-speed motor?
The bearing of high speed motor is wear-resisting, so some high-speed motor USES liquid bearing or air bearing, so that the rotor does not have direct contact with the stator.
Q:Does the motor have a good brush or no brush?
Brush refers to brush, brush dc motor, brush and commutator of the friction and unable to avoid sparks, but relatively speaking, simple control circuit. So, for control, there is a good control of the brush. But for users, a brushless motor clearly has a long life.
Q:The motor does not turn except sound
Is the connection ok? The sound of the urn is the coils of the coils. What's the electric motor.:If it's a single phase of the motor that might be a fault of the current or the initiating device, the third phase is the power supply,.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Hot Searches

Related keywords