Water Tree Retardant XLPE Compound for 10KV and Below Power Cable

Ref Price:
Loading Port:
Payment Terms:
Min Order Qty:
Supply Capability:
1000000kgs kg/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Main Properties & Typical Values

Test Items


Test Method


Typical value

Tensile strength





Elongation at break





Heat ageing properties (Test temperature 135℃, 168hr)

Maximum tensile strength change      

Maximum elongation at break change








Heat elongation (200±3)℃x15minx0.2MPa)

Maximum elongation change under load      

Maximum permanent elongation change after cooled








Impact brittle temp. (-76℃)  

Impact brittle

Failure no.




Dielectric Strength





Dielectric loss factor 50Hz, 20℃


GB/T 1409



Dielectric constant 50Hz, 20℃





Volume resistance (20℃)


GB/T 1410



Gel content





*Relative size of water tree growth


Q/GHPX 114



Note: *Technical property meaning:The percentage of water tree growth size of the water tree retardant XLPE compound

All typical values were tested by press moulding sample under the condition of 180±2 ℃,15min, and pressure over 15Mpa, then cooling to room temperature

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Why this cable has not yet been certified
The manufacture of wire and cable is completely different from that of most electromechanical products
Q:What is the difference between a trunking and a bridge in a weak construction?
Mainly to distinguish the ground which is the ground, the color of the ground is generally yellow-green; wire two is the fire line L and zero line N, no ground wire, look at the plug on the LN mark, the corresponding good.
Q:Is the toilet wire walk on the ground? Are there any hidden dangers?
Budget 1W5 requires the whole machine to include the display of the monitor not too big too much Not used to more
Q:The computer can not open the machine display frequency beyond the scope of the mouse and keyboard do not start can not press F8 how to do
According to the "Power Engineering Cable Design Code" GB-. 5.3.3 only asked for the depth of the cable buried directly: drop the blue skin to the ground depth, not less than 0.7 meters; when located in the roadway or farmland Under the appropriate should be deepened, and should not be less than 1.0 meters. 5.4.3 protected pipe buried in the ground, should meet the requirements under the depth of the pressure and environmental corrosion resistance. Through the uneven settlement of the backfill section and other places to increase the force, it is appropriate to use steel. Another direct burial should be selected armor type.
Q:Galvanized wire tube buried to do anti - corrosion do
Galvanized pipe itself with anti-corrosion coating, you can not do anti-corrosion.
Q:What kind of KVM switch is this configuration below?
Direct selection of reton's 32-port digital KVM, model is: KS-2032C. Fast transmission, wiring is simple. Want to know the price to ask their website on it.
Q:Help look at such a configuration will not have compatibility issues! Do you need to improve? Budget in 5500 or so
Power lines tied together, usb line bundled together, high and low pressure apart. Tie the tie on the line
Q:Cable YJV-3 * 70 + 2 * 35 general wear large SC tube? Ask you.
Charging line and the phone does not match, for the good point of the line just fine
Q:What does the letter of the computer cable model mean?
(The difference between the two cables: WDZ and WDZC are the combustion characteristics of the cable, both halogen-free low smoke flame retardant cable, but the former is a single vertical flame retardant test, which is bundled combustion C class flame retardant Test, but the flame retardant performance requirements are not the same. The meaning of the letter: W refers to the halogen-free; D refers to the low smoke; Z refers to the flame retardant WDZ is halogen-free low smoke flame retardant jacket power cable. WDZC refers to halogen-free low smoke C-class flame retardant reference )
Q:Wire pipe inlet air switch trip how to do?
Wire pipe water problem: In fact, this problem is very serious, then this line should be scrapped or replaced, if you continue to reluctantly use not only to bring you the safety of trouble and the insulation of the wire dropped sharply! Because there is water it will lead to internal leakage can also make the wire heat caused by wire burning and trivial trivial accident, so be sure to take the necessary replacement! Supplement: the wire out of all, with the wire to grab the absorbent gauze and the like back to the twitching, many times for the gauze to dry the water, hair dryer toward the tube to heat the tube to dry and then re-layout of the new line.

1. Manufacturer Overview

Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range