Specifications of Cable Conductor HS137

ACSR Conductor Cable

1.Conductor:Hard drawn aluminium wire

2.Steel core:Galvanized steel wire,solid or concentric stranded

ACSR Conductor, Reinforced pecifications of Cable Conductor HS137

 

 Cable Conductor HS137  

 

Aluminum Conductors Steel Reinforced  ACSR  ASTM B 232 Specifications of Cable Conductor HS137

 

 

Area

Stranding 

and 

wire 

diameter

Approx. 

overall 

diameter

 

Weight

Nominal 

breaking 

load

Nominal DC 

resistance at 

20 deg.

Nominal 

Alum.

Steel

Total

Alum.

Steel

Alum.

Steel

Total

AWGorMCM

mm2

mm2

mm2

mm

mm

mm

Kg/km

Kg/km

Kg/km

kN

Ohm/km

1272

644.51

81.68

726.19

54/3.90

19/2.34

35.10

1795

638

2433

194.00

0.04516

1272

644.51

17.87

662.38

36/4.78

1/4.78

33.42

1777

140

1917

115.85

0.04472

1351.5

684.84

47.10

731.94

45/4.40

7/2.92

35.16

1898

368

2266

160.70

0.04230

1351.5

684.84

86.71

771.55

54/4.02

19/2.41

36.17

1906

679

2585

206.05

0.04250

1431

725.10

50.32

775.42

45/4.53

7/3.02

36.24

2009

393

2402

170.71

0.03994

1431

725.10

91.87

816.97

54/4.14

19/2.48

37.24

2019

719

2738

218.24

0.04013

1510.5

765.35

52.90

818.25

45/4.65

7/3.10

37.20

2120

414

2534

177.89

0.03784

1510.5

765.35

96.84

862.19

54/4.25

19/2.55

38.25

2131

759

2890

230.20

0.03802

1590

805.68

55.48

861.16

45/4.77

7/3.18

38.16

2232

435

2667

187.02

0.03595

1590

805.68

102.13

907.81

54/4.36

19/2.62

39.26

2243

799

3042

242.55

0.03613

80

40.52

14.13

54.65

8/2.54

1/4.24

9.32

112

110

222

23.60

0.7115

101.8

51.61

30.06

81.67

12/2.34

7/2.34

11.71

143

235

378

41.75

0.5613

110.8

56.13

32.77

88.90

12/2.44

7/2.44

12.22

156

256

412

51.25

0.5161

134.6

68.19

39.81

108.00

12/2.69

7/2.69

13.46

189

311

500

61.70

0.4248

159

80.58

46.97

127.55

12/2.92

7/2.92

14.63

223

367

590

72.55

0.3595

176.9

89.48

52.19

141.67

12/3.08

7/3.08

15.42

248

409

657

78.50

0.3237

190.8

96.71

56.39

153.10

12/3.20

7/3.20

16.03

268

441

709

84.80

0.2995

203.2

102.97

91.87

194.84

16/2.86

19/2.48

18.14

285

722

1007

128.80

0.2813

211.8

107.10

62.45

169.55

12/3.37

7/3.37

16.84

297

488

785

93.90

 

 Cable Conductor HS137

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Buy Taipower c 450P with remote control to add audio and video cable
Set-top box with the AV cable connection: yellow - video, red and white - audio, corresponding to the TV's AV input interface can be connected (do not receive the TV component interface). As for the emergence of partial pink, the possible reasons are: . poor contact. You will re-connect the three-color AV cable to the set-top box, on the TV, to ensure good contact. . cable quality. Three-color AV cable may not be the quality, if you can replace a group of try, or use the DVD and other equipment connected with the TV to test the AV line with or without problems. . TV AV input failure. You can use other video source equipment connected to the TV test, such as: DVD, VCD machines and so on. . set-top box failure. May be set-top box AV output port problems, if there are multiple sets of AV output, you can try other port okay, not the case may be the quality of set-top box, call customer service it.
Q:What is the difference between a trunking and a bridge in a weak construction?
If you are talking about the three-core wire, black - ground brown - line of blue - zero line. If it is 3 plugs, your wire is only 2 lines. Then the yellow received L, black received N. The above is the ground wire.
Q:Building decoration wiring pipe elbow with yellow wax tube can you?
The control cable transfers the electrical energy from the power distribution point to the power supply lines of the various electrical equipment The rated voltage of the power cable is generally 06 / 1kV and above, the control cable is mainly 450 / 750V The same specifications of the power cable and control cable in the production, the power cable insulation and sheath thickness than the control cable thick
Q:Is the toilet wire walk on the ground? Are there any hidden dangers?
Budget 1W5 requires the whole machine to include the display of the monitor not too big too much Not used to more
Q:What is the difference between wires and cables?
The introduction of the device is to introduce the cable into the electrical equipment, without changing the explosion-proof type of explosion-proof equipment
Q:Fiber optic cable split box, integrated wiring box, cable terminal box, cable transfer box difference
KVV is the control cable, generally do industrial control; and RVS is twisted pair, generally used for weak system, to eliminate the interference requirements of the occasion, such as two-wire bus system, specifically, the electrical fire bus more Such as RS485 bus and so on.
Q:Is there a difference between PE cable and PE water supply pipe?
Rubber over the bridge surface curing treatment, nice and at the same time to ensure a safe Pressure tonnage: 5 tons to 65 tons, indoor and outdoor are available (and provide only tramway) Uses: used in engineering department exhibition company, power company construction line, play a role in protecting the line Rubber trough ■ tough, insulated, high pressure (maximum load of 65 tons) rubber over the bridge ■ suitable for all outdoor weather, rain, lightning, moisture, flame retardant ■ surface non-slip surface texture ■ Position protection to the type of cable and communication data cable ■ unique design, no need to destroy the ground installation ■ durable, the surface of non-slip surface texture ■ simple installation, easy to move, structural design briefs practical ■ unique elbow, tee, Selection ■ 1 hole, 2 holes, 3 holes, 4 holes, 5 holes design, fully applicable to the exhibition, performing arts, workshops, power, communications, military and other industries 2 Specifications Table 1 Specifications 1000 × 130 × 20 aperture 40 × 13 Weight 12KG (for indoor cable signal line, etc) 2 Specifications 1000 × 275 × 40 aperture 105 × 30 Weight 32KG (for indoor wiring too thick if the wire, etc) 3 Specifications 1000 × 250 × 50 aperture 32 × 35 Weight 7KG (applicable Over motor vehicles and large trucks, etc) 4 Specifications 900 × 500 × 75 Aperture 50 × 60 Weight 19KG (for motor vehicles and forklifts, etc) 5 Specifications 900 × 500 × 75 Aperture 32 × 35 Weight 21KG (for the workshop workshop, such as truck ) 6 Specifications 900 × 620 × 110 Aperture 90 × 90 weight The amount of 28KG (for small trucks and large trucks, etc) 7 specifications 1000 × 310 × 55 aperture 35 × 35 weight 15KG (for workshop workshop forklift or private cars, etc) 8 specifications 770 × 485 × 65 aperture 40 × 40 weight 18KG For the workshop workshop plant forklift, etc)
Q:Wire and cable CCC product consistency is what
Wire of course, is to use a good slightly, the first life, ah, can not buy cheap because of cheap, like China's top ten brands to buy the brand on the purchase of these brands I feel very good ah, Po Sheng , Luneng Taishan, Far East, Shenghua cable, on the up, prosperous photoelectric, Nexans Nexans these brands of wire is still very good. The landlord you can go to the above to learn more detailed information ah, the top ten wire brand is very detailed, the landlord can understand very clearly, the above brand is very good, my father last time to go above to see, and then buy
Q:What does the letter of the computer cable model mean?
(The difference between the two cables: WDZ and WDZC are the combustion characteristics of the cable, both halogen-free low smoke flame retardant cable, but the former is a single vertical flame retardant test, which is bundled combustion C class flame retardant Test, but the flame retardant performance requirements are not the same. The meaning of the letter: W refers to the halogen-free; D refers to the low smoke; Z refers to the flame retardant WDZ is halogen-free low smoke flame retardant jacket power cable. WDZC refers to halogen-free low smoke C-class flame retardant reference )
Q:Wire pipe inlet air switch trip how to do?
Put the water clean, with a table to measure the insulation resistance between the lines, as long as no less than 1.5-2 can.

1. Manufacturer Overview

Location Yunnan, China
Year Established 1998
Annual Output Value Below US$1 Million
Main Markets Southeast Asia:
Mid East:
Domestic Market:
Company Certifications ISO9001,ISO14001,OHSM18001,ISO10012 ISO16949

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port Guangzhou
Export Percentage 1% - 10%
No.of Employees in Trade Department 1000 People
Language Spoken: English; Chinese
b)Factory Information  
Factory Size: Above 300,000 square meters
No. of Production Lines Above 40
Contract Manufacturing OEM Service Offered; Design Service Offered
Product Price Range High; Average