T8 LED GLASS TUBE





1. Parameter:









 





Yunbai Series Model: 




LED FL- 8W-F3-YB40 LED/ 600 MM




 




Input Voltage  (V):AC 180-260V




Power (W) :8W




Current (A)0.076A




Degree of  Protection (IP) :IP20




Material :SMD 3528




Max. Op. Temp.  :40℃




Ambient Temp.  :-10℃-40℃




Ambient  Humidity :35%




Power Factor :0.6




LED Luminous  Flux (lm) :800lm




Beam Angle  (degrees) :320°




Luminous  Efficacy (lm/watt) :100




Color  Rendering Index (Ra) :72




Average Life  (hours) :20000




Lamp Body  Material :Glass




Lamp Holder:G13




Size  (diameter):Ø26




Power :Built-in  Isolating Source 



Driver Model:Constant Current  Driver




Color and  Colour Temperature:White 6500K , Warm White   3000K


















Spec.A    Max(mm)B     Max(mm)B     Min(mm) C    Max(mm)Ø               (mm)
LED FL-8W-F3-TJ589.8  596.9  594.5  604.0  26








5. Key  Specifications/Special Features:

Features:

1) LED tube  integrates a LED light source into a traditional fluorescent form factor

2) Its unique design creates a perfectly uniform visual  appearance, which cannot be distinguished from traditional fluorescent tube  light

3) This product is  the ideal solution for up lamp in general lighting applications

4) The LED tube is  an affordable LED solution suitable for replacing T8 fluorescent lamps

5) The product provides a natural lighting effect for use in  general lighting applications, as well as instant energy-saving, an  eco-friendly solution

6) Designed to replace fluorescent T8 tubes, the LED T8 offers  an incredible lighting performance that reduces both electricity and  maintenance costs

7) With the long lamp lifespan and wide range of operating  temperature, it is ideal for applications such as offices, warehouses, car  parking, factories and kitchens








6.  Benefits:

1) Direct  replacement retrofit for fluorescent T8 tubes at much low-energy consumption

2) For retrofit on conventional magnetic ballast circuits by  simply exchanging the starter in the installation with the dummy start  supplied with the tube

3) Excellent  heat-dissipation

4) No buzzing  noise, fluorescent flickering and RF interference

5) Eliminates dark  regions at both end of the T8 tube

6) High-lumen  maintenance















7. Installation Instruction


















 






















































































































































































8.  INSTALLATION DIRECTIONS:




1. Before installation, please read instruction carefully and  preserve it well.
2. Only maintained and installed by qualified electrician.
3. Before installation, please cut off the main power.
4. Do not connect the lamp to main supply until installation is  completed.
5. Please DON’T USE LED TUBES with BALLASTS and STARTERS.
6. Please follow the Connection Schema for correct connection.  Make sure the appliance has been mounted safely.







9. CAUTION:      
1. Turn off the switch when replacing and cleaning.
2. Wipe lamp with a dry duster.
3. Do not use any chemical duster or solvent such as oil or  thinner.
4. Do not spray insecticide on this lamp.



Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:How to choose daylight lamp? What is the light bulb specification?
Electric fluorescent starter switch role in the circuit, it consists of a neon tube and a capacitance in parallel, and the role of the capacitor to eliminate the power supply of electromagnetic interference with ballast tank formation, and increase the voltage amplitude of the start pulse. An electrode in the discharge tube with double metal, use neon bulb discharge heating, make the bimetallic strip when open and close, inductance ballast current mutation on both ends of the tube and generate high voltage pulse. When the fluorescent lamp after access circuit, electric fluorescent starter began to glow discharge between two electrodes, the bimetallic strip heat expansion and contact with the static contact extremely, so the power supply, ballast, filament and electric fluorescent starter constitute a closed loop, current filament preheating, 1-3 seconds when the heating time, electric fluorescent starter of glow discharge between two electrodes, then the bimetallic strip cooling and static contact is extremely disconnected, when two electrodes disconnect instantly, the current in the circuit suddenly disappeared, so ballast produces a high voltage pulse, and it has to do with power superposition, on both ends of the tube and, make the inert gas ionization inside the tube caused by arc discharge, in the process of normal light, ballast self-induction is still stable circuit in current role.
Q:What is the category of LED bulbs, T6, T8 or whatever?
I guess the owner is wrong T-tube, tube lamps, just ordinary daylight tubes, each T is 1/8 inch (inch) The T8 lamp is a lamp tube with a diameter of an inch T12 diameter 38.1 mm, T10 diameter 31.8 mm, T5 diameter 16 mm T4 diameter 12.7 mm T3.5 diameter 11.1 mm, T2 diameter 6.4 mm, etc LED lights include high power and low power, LED wall lamp, LED digital tube LED lighting, LED lighting, etc A little help to the landlord
Q:How does the lamp line connect
The one that used to be in the early part of the world, which requires the regenerator to cooperate with the light, is an inductance ballast, and the fluorescent tube now needs to glow without the regenerator. The ballast that doesn't need a regenerator is an electronic ballast. Ask to sell tubes of the owner, they all know and electronic ballast inductance ballasts, now basically eliminated inductance ballasts, everybody understand the electronic ballast is enough. If it is an old lamp, it will meet the inductive ballast. The lamp tube has two feet on each side, and the left and right sides are four feet
Q:What's the matter with the light bulbs?
It's the regenerator problem, or the regenerator block.The wiring didn't catch up.
Q:How does the T8LED light tube replace the fluorescent lamp tube
Tube at both ends a firewire, on the other side is zero, the two feet per head are connected together, by one or two can be, if with neon bulb starter, starter can be twisted off, then remove ballast two joint together can change LED bulb.
Q:What is the most suitable power efficiency for leds?
It's about 0.97, it's still pretty high, I bought the lamp tube of zhaochang, very bright, used for two years, still like new
Q:How many lumens is the T5 bulb of 18W
The fixed bar is still rolling. Let's try a VGA line, if I can't do that, that's the problem of the screen itself. Like screen drive or line problems, not the LCD panel itself.
Q:Why is the household daylight lamp attached to the battery?
No, there aren't more than 40 fluorescent lights. Anything else.How big is the tube and the battery? There is nothing else.
Q:What causes the red light on both ends
There are two reasons for this: 1. The internal gas shortage causes!
Q:Led lamp tube t8 good or t5 good
The specification of fluorescent lamp is the diameter of tube, length. Look at your lighting requirements, T8 pipe size, of course, the light effect will be better, the same length of lamp tube T8 will be more than twice as bright as T5, and the brightness is much better. The quality of the lamp is not so good at present. The main view is lamp tube with light, electric power and heat dissipation processing.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range