T8 LED glass tube,16W, 88leds/1200mm, 1550lm, SMD3528,G13,Ø26, AC180-260V,Constant current driver, White6500K,Warm white3000K,CE

Ref Price:
Loading Port:
China Main Port
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
-

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

T8 LED GLASS TUBE





1. Parameter:









 





Xuejing Series Model: 




LED FL-16W-F3-XJ88 LED/1200 MM




 




Input Voltage  (V):AC 180-260V




Power (W) :16W




Current (A)0.14A




Degree of  Protection (IP) :IP20




Material :SMD 3528




Max. Op. Temp.  :40℃




Ambient Temp.  :-10℃-40℃




Ambient  Humidity :35%




Power Factor :0.6




LED Luminous  Flux (lm) :1550lm




Beam Angle  (degrees) :320°




Luminous  Efficacy (lm/watt) :90




Color  Rendering Index (Ra) :72




Average Life  (hours) :20000




Lamp Body  Material :Glass




Lamp Holder:G13




Size  (diameter):Ø26




Power :Built-in  Isolating Source 



Driver Model:Constant Current  Driver




Color and  Colour Temperature:White 6500K , Warm White   3000K


















Spec.A    Max(mm)B     Max(mm)B     Min(mm) C    Max(mm)Ø               (mm)
LED FL-16W-F3-XJ1199.41206.5  1204.1  1213.6  26








5. Key  Specifications/Special Features:

Features:

1) LED tube  integrates a LED light source into a traditional fluorescent form factor

2) Its unique design creates a perfectly uniform visual  appearance, which cannot be distinguished from traditional fluorescent tube  light

3) This product is  the ideal solution for up lamp in general lighting applications

4) The LED tube is  an affordable LED solution suitable for replacing T8 fluorescent lamps

5) The product provides a natural lighting effect for use in  general lighting applications, as well as instant energy-saving, an  eco-friendly solution

6) Designed to replace fluorescent T8 tubes, the LED T8 offers  an incredible lighting performance that reduces both electricity and  maintenance costs

7) With the long lamp lifespan and wide range of operating  temperature, it is ideal for applications such as offices, warehouses, car  parking, factories and kitchens








6.  Benefits:

1) Direct  replacement retrofit for fluorescent T8 tubes at much low-energy consumption

2) For retrofit on conventional magnetic ballast circuits by  simply exchanging the starter in the installation with the dummy start  supplied with the tube

3) Excellent  heat-dissipation

4) No buzzing  noise, fluorescent flickering and RF interference

5) Eliminates dark  regions at both end of the T8 tube

6) High-lumen  maintenance















7. Installation Instruction


















 






















































































































































































8.  INSTALLATION DIRECTIONS:




1. Before installation, please read instruction carefully and  preserve it well.
2. Only maintained and installed by qualified electrician.
3. Before installation, please cut off the main power.
4. Do not connect the lamp to main supply until installation is  completed.
5. Please DON’T USE LED TUBES with BALLASTS and STARTERS.
6. Please follow the Connection Schema for correct connection.  Make sure the appliance has been mounted safely.







9. CAUTION:      
1. Turn off the switch when replacing and cleaning.
2. Wipe lamp with a dry duster.
3. Do not use any chemical duster or solvent such as oil or  thinner.
4. Do not spray insecticide on this lamp.



Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:What is the reason for the movement of light in the tube
Flash is because the lamp tube is old, fast, ready for new, it won't last long
Q:The LED fluorescent tube plus the ballast why is it still going to press?
Use neon bulb discharge heating bimetallic strip in open and close, cause inductance ballasts and generate high voltage pulse electric current mutations on both ends of the lamp and ballast used in fluorescent originally when the above is to make haste to booster.
Q:20wled bulbs are more energy-efficient than 20w fluorescent bulbs
Led fluorescent lamp is twice as common fluorescent lamp, luminous efficiency is 10 w led fluorescent lamp brightness is equivalent to 20 w common fluorescent lamp brightness, what's more, the led fluorescent lamp light Angle of 120 degrees, ordinary fluorescent lamp light Angle is 360 degrees, so the led fluorescent lamp to use more efficient, and common fluorescent lamp ballasts, it also consumes, and led fluorescent lamp does not need. So led fluorescent lamp is very energy-saving, normally can guarantee 3 years.
Q:Electronic ballast tube lamp change led lamp tube how to change circuit how to do
Usually direct 220V, in the package of the lamp tube has the wiring diagram, does not use the original ballast, the nature is different
Q:I have LED lights on fluorescent lamp tubes, and I have tested five times a dc
No good. 220v is a valid value. The maximum value is 310v, and it burns instantly.I hope my answer will help you.
Q:What is the idea of an LED daylight lamp called T5 or T8?
The integration of tubes: mainly in the traditional lamps and lanterns, also is the T5 trichromatic lamp, as a result of the three primary colors T5 tubes need rectifier, and trichromatic lamp life is limited, the designer in order to facilitate the rectifier and convenient replacement bulbs, use of integrated design. Now the LED lamp just began to enter the market, many companies also modeled on the traditional lamps and lanterns to design.
Q:What's the difference between a single input and a double-end input?
Single end input is the only one that has a connection Double-end input is designed to be able to use the interface of the traditional lamp holder.
Q:What does LED light tube integration mean
Integration is a strap that can be plugged into a power supply. The other kind of branch is that only the lamp tube needs to be matched with the stent, the old stents in the home also can be used, this is for the people to replace and transform also save the cost
Q:Use LED fluorescent lamp tube to replace, the line of original daylight-tube seat should be refitted
So old ballast, the ballast uninstalled, directly to the card on the two old fluorescent lamp wire short respectively, and then to the outside power, install the LED fluorescent lamp with respect to OK
Q:Is a three-male LED fluorescent lamp? How the quality?
All the leds in sanxiong are made of the chip of the corry, which is very expensive, which is about a dozen times better than the normal LED product, but the quality, the light color aspect is not to be said, very good. See the product that you want to use good or general, want to use good can choose, if required, recommended the other manufacturers, including, Anatole, group of states, Carl is fine.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range