Application Scope

Reactive compensation and harmonic filtering of electric power, petroleum, steel, chemical, metallurgy, wind power, semiconductor manufacturing, water supply and drainage industry.

Technical Features:

If the unbalanced 3-phase system isn`t serious, it works with two kinds of compensation (3-phase model and split-phase model), so as to avoid overcompensation or undercompensation. TSM dynamic compensation cabinet is composed of TSS split-phase compensation cabinet and TSC dynamic compensation cabinet or TSF dynamic compensation cabinet.

For example, a user needs a set of dynamic compensation device combined of 3-phase and split-phase compensation, and the split-phase compensation capacity is 240kvar (compensation precision 8kvar), the 3-phase compensation is 400kvar. The device is selected according to the table below, namely one set of SY-TSS-240/192-400 and one set of SY-TSC-400/320-400. The specific selection should take TSS split-phase compensation and TSC dynamic cabinet or TSF dynamic compensation cabinet.

TSS Split Phase Compensation Cabinet: SY-TSS-240/192-400

NO.

TSS 3-Phase Installed Capacity

kvar

TSS 3-Phase Fundamental Capacity

kvar

Grading Manner

(Coding)

Single-Phase Compensation precision

kvar

Compensation Cabinet Num.

(set)

Compensation Cabinet Size

(L*D*H)

Compensator Capacity

kvar

1240192

Constant capacity 8 grade switching

1:1:1:1:1:1:1:1
811200*1000*2200<240< span="">


TSC型动态补偿柜:SY-TSC-400/320-400

NO.

TSC Installed Capacity

kvar

TSC Fundamental Capacity

kvar

Grading Manner

(Coding)

Compensation precision

Compensation Cabinet Num.

(set)

Compensation Cabinet Size

(L*D*H)

Compensator Capacity

kvar

1400320

Coding

1:2:4
<46< span="">11200*1000*2200400

Note: 1. The voltage grade, capacity and grading manner can be made according to customer requirements.

      2. The data in the table are for reference only, we reserve the right to change the data.

 

Q: S-350-12 monitoring dedicated switching power supply 12V29A transformer connection
12V switching power supply connected to the positive and negative, then the power will not burn, and most of the output is not, if it is a new power supply, then you can change one. The next time to pick up the first time with a multimeter to measure whether there is a short circuit, the best one of a power, on a power out of an image, no image and then check.
Q: A led lamp with a dedicated power to bring a few lights
Four, warm tips: 1, compared to the merits of power supply can not only compare the number of W marked by the power supply, depending on the actual load power supply; electronic material selection; transformer whether the aluminum transformer. 2, the proposed customer knowledge of the lamp with a certain understanding, you can configure their own test tools to detect the actual power of each batch of lights, matching more economical, real power. Professional power supply manufacturers Links: LED switching power supply Shenzhen switching power supply switching power supply rain power
Q: EPS emergency power supply and DC screen is one thing, what is the difference between the two?
DC screen [1] is a short description of the DC power supply operating system. Universal name for the intelligent maintenance-free DC power supply screen, referred to as DC screen, universal model for the GZDW. Simply put, the DC screen is to provide a stable DC power supply equipment. (Directly converted to DC220V or DC110V when inputting 380V power supply, and input directly to battery power when input (mains and standby) are input - DC 220V or DC110V: it can be said to be an industry Dedicated emergency power supply). Power plants and substations in the power of power supply are now used in DC power supply, which for the control load and power load and DC accident lighting load to provide power, is the basis of contemporary power system control and protection. The DC screen is composed of crossover power unit, charging module unit, step-down silicon chain unit, DC feed unit, power distribution monitoring unit, monitoring module unit and insulation monitoring unit. It is mainly used in small power plants, hydropower stations, substations, and other users of DC equipment (such as petrochemical, mining, railway, etc.) for power substation and sub-circuit. Electrical protection and fault lighting and other occasions.
Q: Industrial electricity in the DPS.UPS, etc. are temporary power to Caesar ah
DPS is the power of the equipment being tested, UPS is uninterrupted power supply,
Q: Industrial plant design 10 kV substation from the power supply to the client side, such as mechanical equipment, such as the overall structure of the connection diagram
You design this content contains the transmission and variable distribution of two large, from your question you can see you like no clue, do not know where to start, step by step,
Q: Meizu special mobile power is which brand?
In fact, that KINI mobile power, rest assured that the use of, really bad.
Q: Apple 4s dedicated mobile power are what?
Charging Po has 5V / 2A charge output, 5V / 1A charge output. 2, Apple 4S use 5V / A charge output. 3, selected by the polymer lithium battery as a storage unit.
Q: US Industrial Electricity Voltage
2. Requirements for "Scope A": 115 ~ 120V System: When lighting: 110 ~ 125V of electrical equipment; power supply point 114 ~ 126V. No lighting: electrical equipment at 108 ~ 125V; power supply point 114 ~ 126V. 460 ~ 480V system: (including 480 / 277V three-phase four-wire system) When lighting: power equipment at 440 ~ 500V; power supply points 456 ~ 504V. No lighting: electricity equipment at 432 ~ 500V; power supply points 456 ~ 504V. 13200V system: power supply point 12870 ~ 13860V.
Q: Industrial UPS power supply how to choose?
UPS power supply battery size determines the length of the load power supply, the specific load is also based on the need to set, such as: If the injection machine in the electricity after the break need 1 hour power supply to ensure its normal stop, then our battery Size needs to be based on the size of the injection molding machine to match the appropriate battery, any of the Group's UPS power supply can match the UPS battery, you can also have their own customers to buy.
Q: Led special power how to wiring
GND (three digits), then accept the light of the negative (usually black wire or white wire); 12V (three digits), then you light the positive pole (usually red wire or brown wire);