Low Voltage Reactive Power Compensat SY-TSF Series

Ref Price:
Loading Port:
Tianjin
Payment Terms:
TT OR LC
Min Order Qty:
1 unit
Supply Capability:
10 unit/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Application Scope

Reactive compensation and harmonic filtering of electric power, petroleum, steel, chemical, metallurgy, wind power, semiconductor manufacturing, water supply and drainage industry.

Technical Features:

SY-TSF low-voltage SVG and harmonic filter are designed for load of large harmonic content and with rapidly changing reactive power compensation (eg. welder, rolling DC motor, frequency converter, etc.). The device can automatically track the load changing condition and control the automatic switching of each filter branch in real-time to make the power factor of system stay in the best value while filtering load harmonic current.


SY-TSC-□/□/-660


NO.

Installed Capacity

(kvar)

Fundamental  Capacity

(kvar)

Grading Manner

(Coding)

compensation precision

(kvar)

Compensator Num.

(set)

Installed

Filter


Compensation Cabinet Size

(L*D*H)

Compensator Capacity

(kvar)

DC Drive for Reference

(kW)

1600400

Coding

1:2:4
5715times1200*1000*2200600500
2780520

Coding

1:2:4
7425times1000*1000*2200
1000*1000*2200
279+501650
3900600

Coding

1:2:4
8625times1000*1000*2200
1100*1000*2200
323+577750
4960640

Coding

1:2:4
9125times1000*1000*2200
1200*1000*2200
341+619800
51080720

Coding

1:2:2:2
10325、7times1000*1000*2200
1200*1000*2200
446+634900
61200800

Coding

1:2:2:2
11435、7times1000*1000*2200
800*1000*2200
800*1000*2200
496+352+3521000
71320880

Coding

1:2:2:2
12635、7times1100*1000*2200
800*1000*2200
800*1000*2200
546+387+3872×650
815001000

Coding

1:2:4:4
9135times1000*1000*2200
1100*1000*2200
1100*1000*2200
342+579+5791250
916201080

Coding

1:2:4:4
9835times1000*1000*2200
1200*1000*2200
1200*1000*2200
368+626+6261350
1018001200

Coding

1:2:4:4:4
8045、7times1000*1000*2200
1000*1000*2200
1000*1000*2200
1000*1000*2200
300+500+500+5001500
1119201280

Coding

1:2:4:4:4
8545、7times1000*1000*2200
1100*1000*2200
1100*1000*2200
1100*1000*2200
318+534+534+5341600
1220401360

Coding

1:2:4:4:4
9145、7times1000*1000*2200
1100*1000*2200
1100*1000*2200
1100*1000*2200
342+566+566+5662×1000

 
SY-TSF-□/□-400型

NO.

Installed Capacity

(kvar)

Fundamental  Capacity

(kvar)

Grading Manner

(Coding)

compensation precision

(kvar)

Compensator Num.

(set)



Installed

Filter

Compensation Cabinet Size

(L*D*H)

Compensator Capacity

(kvar)

Transformer for Reference

( kVA)

112080

Coding

1:2
2715times800*1000*2200120160
2180120

Coding

1:2
4015times800*1000*2200180250
3250167

Coding

1:2:4
2415times1000*1000*2200250315
4300200

Coding

1:2:4
2915times1000*1000*2200300400
5350233

Coding

1:2:4
3315times1000*1000*2200350500
6400267

Coding

1:2:4
3815times1100*1000*2200400500
7500333

Coding

1:2:4
4815times1200*1000*2200500630
8600400

Coding

1:2:4
5725times1000*1000*2200
800*1000*2200
214+386800
9700467

Coding

1:2:4:4
4225times1000*1000*2200
1000*1000*2200
324+3761000
10800533

Coding

1:2:4:4
4825、7times1100*1000*2200
1000*1000*2200
370+4301000
11900600

Coding

1:2:4:4
5525、7times1100*1000*2200
1000*1000*2200
415+4851250
121000667

Coding

1:2:4:4
6125、7times1200*1000*2200
1000*1000*2200
462+5381250
131200800

Coding

1:2:4:4:4
5335、7times1000*1000*2200
1000*1000*2200
800*1000*2200
400+466+334
(1+4)+(2+4)+4
1600
141350900

Coding

1:2:4:4:4
6035、7times1100*1000*2200
1000*1000*2200
800*1000*2200
450+525+375
(1+4)+(2+4)+4
1600
1515001000

Coding

1:2:4:4:4
6735、7times1200*1000*2200
1100*1000*2200
900*1000*2200
500+584+416
(1+4)+(2+4)+4
2000
1616001067

Coding

1:2:4:4:4:4
5645、7times1100*1000*2200
1000*1000*2200
800*1000*2200
800*1000*2200
417+487+348+348
(1+4)+(2+4)+4+4
2000
1718001200

Coding

1:2:4:4:4:4
6345、7times1100*1000*2200
1000*1000*2200
800*1000*2200
800*1000*2200
415+479+353+353
(1+4)+(2+4)+4+4
2000
1820001333

Coding

1:2:4:4:4:4
7045、7times1200*1000*2200
1100*1000*2200
900*1000*2200
900*1000*2200
522+610+434+434
(1+4)+(2+4)+4+4
2500
1922501500

Coding

1:2:4:4:4:4:4
6555、7、11times1200*1000*2200
1000*1000*2200
800*1000*2200
800*1000*2200
800*1000*2200
483+564+401+401+401
(1+4)+(2+4)+4+4+4
2500
2025001667

Coding

1:2:4:4:4:4:4
7255、7、11times1200*1000*2200
1100*1000*2200
900*1000*2200
900*1000*2200
900*1000*2200
536+626+446+446+446
(1+4)+(2+4)+4+4+4
3150Note: 1. The voltage grade, capacity and grading manner can be made according to customer requirements.

Note: 1. The voltage grade, capacity and grading manner can be made according to customer requirements

           2. The data in the table are for reference only, we reserve the right to change the data.

           3. It suggests adding a head line-in switch if the installed capacity is more than 1000kvar.

 

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Industrial power cabinet generally use what brand of power
At present, industrial UPS, the market usually use several brands. 1.EMERSON, EMERSON not only provide UPS products, but also provide supporting engineering solutions and engineering support.
Q:What is the allowable fluctuation range of the industrial standard power supply 380v power supply voltage?
Industrial standard power 380V is a three-phase supply voltage, which allows the deviation of the nominal system voltage of 10% of the taxi, that is divided into: 342--418V.
Q:Do you want to use the DC24V of the alarm system for the power cord of the bus-specific fire-fighting telephone?
1, the bus system of the fire telephone extension or telephone jack is no need for external power supply, through the fire telephone bus directly access the fire telephone controller. But the fire telephone controller (usually with the alarm controller set disk) requires DC24V power supply, and by the fire alarm controller to provide;
Q:UPS uninterruptible power supplies, electronic power products, industrial computers and embedded computers.
This product, then, are mature products, that is, high-tech missile aircraft submarine technology, the world is not a lot of countries in the military competition? The The Some people sell lighters to sell towels a year can sell hundreds of W, in the final analysis, or sales of technical problems.
Q:Computer power can be inserted in the air conditioning dedicated socket
The air conditioning socket can provide a greater current than the ordinary socket (not forcibly filling the electrical current).
Q:Do you need a separate dedicated power supply for each color dome camera?
General color hemisphere no infrared lamp power consumption is small, a 1A power supply if it is safe, then with 2 is no problem
Q:Industrial electricity in the DPS.UPS, etc. are temporary power to Caesar ah
Can be used as a delay power supply, but the power supply time is limited, according to the battery configuration,
Q:Industrial 380 inverter how to enter the home 220 power supply work
Surely need to install the press
Q:The 2-way power supply is connected to a 16A 8-bit PDU in the cabinet using a 16A industrial connector
1 Road 16A into, just connected to the 16APDU Lane, just right. Second Road, then it is estimated that a then electricity, a UPS. Smart is not intelligent and it does not matter. A little better room will be equipped with this.
Q:What is the difference between computer power and industrial switching power supply?
No difference, but the power is not the same, use is not the same

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range