• Solar Pump Irrigation Systems Based On AC and DC power System 1
  • Solar Pump Irrigation Systems Based On AC and DC power System 2
  • Solar Pump Irrigation Systems Based On AC and DC power System 3
Solar Pump Irrigation Systems Based On AC and DC power

Solar Pump Irrigation Systems Based On AC and DC power

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 unit
Supply Capability:
400 unit/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

1.  Description of solar pumps. 

CNBM Solar Water Pump is the pumping facility driven by solar energy, which consists of a solar pumping inverter and a pump. Solar water pumps kit is called  solar pumping system combining with solar arrays designed according to different head and daily water flow for application. System is widely utilized for agriculture irrigation,desert control,pasture animal husbandry,city landscaping,daily water supply, etc.

 

In recent years, with the development of photovoltaic products from city application to huge demands of agriculture,pasture,desert areas, CNBM Solar Pond Pump has become the leading products combining photovoltaic industry with traditional industry such as agriculture water conservancy,desert control,daily water supply,city landscaping, etc.


CNBM Solar Pump driven by infinite solar energy, works from sunrise, and stops at sunset, need no connection to grid power nor diesel oil and battery. System can irrigate directly or store water instead of electricity in a reservoir. Solartech Solar fountain Pumps works with sprinkling irrigation, drip irrigation and infiltrating irrigation facilities, can be more efficient for water saving and dramatically lower the cost of using fossil energy.

 

2. Technical Function

1>  High efficient DC brushless motor requires less solar array. Rich social benefits.

2>  Optional centrifugal pump for big flow and helical rotor pump for high lift.

3>  High efficient semiconductor device used in main circuit. High reliability. Up to 98% conversion efficiency  of controller.

4>  Independent intellectual property of dynamic VI maximum power point tracking (MPPT) algorithm. Fast  response  and good stability. 99% MPPT efficiency.

5>  Full automatic operation. Complete protection functions. Integrated with water level monitor to prevent

  overflow and dry running.

6>  Full aluminum alloy case. IP52 protection grade. Ambient temperature: -20~+60.

Product Specifications


3. Specification details. 

1> Flow: 0.4m³/h~22m³/h

2> Head: 10m~210m

3> Power: 0.1~3Kw

 

4. FAQ

1> May we ask if the bare pump or the whole pump system would be all right for you to arrange the delivery?

     The bare pump and the who systems would be all acceptable at your side. A controller will be equipped with the pump freely. Regarding the whole system, we can also make the best solar panels configuration according to your requirements. 

2> Does your controller have the MPPT Function?

     Yes, our controllers have. This would be not a problem. 

3> Can your pump work automatically?

     Yes, it would be the basic advantage of solar water pumps. 


Solar Pump Irrigation Systems Based On AC and DC power

Solar Pump Irrigation Systems Based On AC and DC power


Q:How is the pump level of submersible sewage pump determined?
Generally as:The bottom elevation of sump sump plus 300 is the water level of pump stopThe top 300 of the sump top elevation is the pump water level
Q:What is the distance between the pump and the wall?
Mainly depends on the maintenance, installation is convenient, but there is no other requirements.
Q:What are the constant pressure pumps?
CatalogBooster pump definitionMechanical classification, methane booster pump, pneumatic booster pumpGas-liquid booster pumpAir booster pumpChlorine booster pumpWorking principlefunctionMechanical installationMechanical selection of booster pump definitionMechanical classification, methane booster pump, pneumatic booster pumpGas-liquid booster pumpAir booster pumpChlorine booster pumpWorking principle
Q:How to install, operate and maintain the pipeline booster pump?
The motor coil is provided with a safety protector, and when the pump is out of order or the water is not pumped, the motor can automatically break down when the temperature of the motor exceeds the prescribed value, and the motor can automatically resume operation after the temperature rise of the motor is decreased. The booster pump motor is a capacitor running type motor. When the pump leaves the factory, the rotation direction has been adjusted. If you need to replace the capacitor or re connect, press the arrow direction on the pump body to mark the connection. To ensure safety, use the three - core safety socket with ground wire.
Q:What are the causes of pump shock?
6., water pump relatively serious cavitation, improve the water level of the water tank, reduce water output7., impeller and motor rotor imbalance, overhaul8. pump shaft bending or abrasion overhaul
Q:What is the difference between swashplate pump and crankshaft pump?
Swash plate pump motor is driven as a coaxial swash plate drive plunger pump crankshaft work produces high pressure water in general simply and motor rotor to form a 90 degree angle of the motor through the crankcase to drive the piston to work in general the crankshaft speed is relatively high in the 2800 turn left and right to use the cost of the swash plate speed the use of less than 300 kg pressure in about 1400 when the crankshaft is relatively high but in more than more than 300 kilograms of crankshaft pump highlights the advantage of his adopted lookout!!!
Q:What are the main performance parameters of hydraulic pumps?
Main performance parameters of hydraulic pump:1. Hydraulic pump pressureHydraulic pump operating pressure is the pump (or motor) in actual work output (or input) oil pressure, determined by the external load.Rated pressure refers to the maximum pressure under continuous running in accordance with the test standards under normal working conditions. The size of the pump is limited by the service life, and the service life of the pump (or motor) will be shorter than the design life if it exceeds the rated pressure. When the work pressure is greater than the rated pressure, it is called overload.
Q:Fire hydrant pump button, under what circumstances do not need to install?
General high voltage system, when normal, use small pump steady pressure.Fire hydrant button lifting pump is one of the multiple pumping methods, and it is an important link of reliable operation of the system.
Q:Harm of air pump and pump
Minimum starting current when centrifugal pump of such a small impact on the grid but long closed operation will make the liquid in the pump to the pump overheating temperature is too high will lead to the problem of the seal to a certain temperature will cause deterioration of oil bearing bearing caused by excessive wear and even bite dead
Q:What does "anti pump" mean in pump operation?
Function: anti pump effect when used for pumping concrete pumping occurs overpressure, the pumping pressure is above 25MPA, the concrete conveying pipe out of ash, can be understood as the precursor of pipe blockage, at this time should immediately use the anti pump, the concrete from the conveying pipe in the suction into the hopper, thus preventing plugging happen

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Related keywords