SET SCREW EMT CONNECTOR-STEEL,EMT steel Connector
- Loading Port:
- Ningbo
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1000 pc
- Supply Capability:
- 300000 pc/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Description:
EMT steel Connector
American Standard, NPT Thread
UL Standard 514B
Size: 1/2" to 4"
Material: Steel
Steel emt connectors are used to bond EMT conduit to electrical junction boxes or enclosures. JIACHI EMT steel connectors provide concrete tight connections when taped and properly secured with the included locknut, and are rated for electrical applications above 600 volts. Their heavy gauge steel construction maintains mechanical protection and solid grounding of the conduit to the designated electrical junction box or enclosure. Additionally, EMT conduit connectors are pure steel and zinc plated for excellent corrosion protection.
Applications:
EMT steel connector: Joins steel EMT conduit to Electrical box and enclosure
•Connect & effectively bond EMT conduit to steel outlet boxes, load centers & other metal enclosures
•May be used indoors and in concrete-tight applications when taped
•Body and locknut made with die-cast zinc alloy
•Set screw made with zinc-plated steel
•Tri-Drive screw head design for use with Phillips, slotted and square screwdrivers
•Screw thread is designed to not vibrate loose
•Reversible locknut designed to cut through protective coatings on boxes & enclosures
•UL standard for safety
•Application type : EMT
•Electrical Product Type : Standard Fitting
•Fitting type : Connector
•Indoor/Outdoor : Indoor
•Paintable/Stainable : No
•Material: steel
•Trade Size (in.) : [1/2"] [3/4"] [1"] [1-1/4"] [1-1/2"] [2"][2-1/2"] [3"] [4"]
Specification:
Pictures:
Production:
- Q: 1000 kW 600 m cable to use much
- Three-phase 380V, 1000 kilowatts load, the working current is about: 1899A. The total area of copper cable is not less than: 1200 mm2 copper cable. . the cable is usually a few or several groups of wires (at least two each) twisted from the rope-like cable, each group of wires are insulated from each other, and often around a center twisted, the entire outer package Highly insulated cover. Cable with internal power, external insulation characteristics. . the cable has power cables, control cables, compensation cables, shielded cables, high temperature cables, computer cables, signal cables, coaxial cables, fire cables, marine cables, mining cables, aluminum cables and so on. They are composed of single or multi-strand wire and insulation layer, used to connect the circuit, electrical appliances and so on.
- Q: Is the cable head made of every building?
- First, the cable production and installation of each building has. Second, the cable terminal set of waterproof, stress control, shielding, insulation in one, with good electrical and mechanical properties, in a variety of harsh environmental conditions for long-term use. With the advantages of light weight, easy installation and so on. Cable terminal is widely used in electric power, petrochemical, metallurgy, railway ports and construction and other fields. Third, the production process: including the following: . cut off the excess cable; . the cable protective layer of the stripping; . conductor connection; . wrapped around insulation (or shrink pipe); . install the connector shell; . ; . for sealing treatment.
- Q: What is the meaning of PG + digital markings for electrical wiring?
- Will the general power cable control cable can do the largest square...
- Q: 3 by 16 cable is a few flat? How? That 5 by 16?
- 1 Definitions and basic tasks Communication lines and ancillary facilities Routine inspection operations are based on regional characteristics of regular light cable line inspection and protection line publicity, timely detection of problems, troubleshooting factors to ensure smooth communication; communication lines and ancillary equipment to make up Strong, to ensure that the optical cable lines and ancillary equipment integrity is good to prevent the occurrence of failure
- Q: How much of the cable with the switch?
- The switch is not selected according to the cable and is selected according to the current. The cable is determined by the size of the power (converted to current) and the distance from which the distance is far. The greater the power distance, the greater the cross-sectional area of the required cable. For example: 15KW motor selection cable current I = P / 1.732UcosΦ = 15 / 1.732 / 0.38 / 0.8 = 28A if it is close (within tens of meters), copper cable 6 square millimeters, aluminum cable 10 square millimeters. If it is in the distance (a few hundred meters), copper cable 10 square millimeters, aluminum cable 16 square millimeters. If it is long distance (close to kilometers), copper cable 16 square millimeters, aluminum cable 25 square millimeters. The switch is regardless of distance, completely based on the load current to choose, generally according to the load current of 1.5 times to 2 times to choose.
- Q: 5 air conditioning can be used 4 square cable
- You do not use the 9V power supply, a long time will burn the router.You'd better measure the original adapter voltage, if you want to extend the power cord, it is best to use a thick line of reliable connection, you can not start now, you can not start Depending on whether the extension line is too thin, causing the voltage drop too much.It is necessary to extend the front end of the adapter can extend the 220V power cord.
- Q: The difference between nylon balls and geese and ducks
- If the 2.5 square copper wire for the output extension cable, 20 meters distance, the total resistance of about 2 * 1.7 * 0.2 / 2.5 = 0.272 (ohms), the current maximum 1.8A, the voltage drop is 0.272 * 1.8 = ), The charging voltage is 55-0.5 = 54.5 (volts), a difference of about 1% will not have any impact on the battery. However, the third floor, said Ye Hao, you can put the charger put the debris room, from your house put a 220V power cord down, home and then engage in a switch control. It is best to design a light at home, can intuitively see if the electricity is full. That's better. Design light, teach you a way: to find a bad leakless protector, open there is a coil-like ring-shaped stuff, called zero sequence current transformer, it will be down, be careful, do not put Transformers inside the coil hurt, get down, in the transformer two thin lines connected to a light-emitting diode. And then your 220V power cord line of fire from the center of the sensor through, around 3-5 turns. In this way, as long as there is current flow, the light-emitting diode will be bright, when the charge is over, the charging current is close to zero, the light-emitting diode will be extinguished. You can from the light-emitting diode is lit to determine whether the electric has been filled. I also have an electric bike that is so charged.
- Q: How do I ask for cable prices? How many tons is one or more?
- Yellow line is video, red and white are audio, you can only pick one!
- Q: 6 square cable up to how many air conditioning (1.5P)
- 7 kilowatts of electricity with what specifications of the wire if it is single-phase 220V, then 7 kilowatts of current is 7000 × 220V = 31.8A, check the electrical manual 4 square copper wire interception is 33A, to meet the requirements.
- Q: 25 square copper cable how much money one meter?
- 3000w electrical work at 220V voltage is about 13.6A (current = power divided by voltage). Copper core line of the working current is generally a square 4-6A. That is to say you use 3-4 square power cord more secure.
Send your message to us
SET SCREW EMT CONNECTOR-STEEL,EMT steel Connector
- Loading Port:
- Ningbo
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1000 pc
- Supply Capability:
- 300000 pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords