• Refractory class-I material strong acid and alkali-resistant FRP Bridge System 1
  • Refractory class-I material strong acid and alkali-resistant FRP Bridge System 2
  • Refractory class-I material strong acid and alkali-resistant FRP Bridge System 3
  • Refractory class-I material strong acid and alkali-resistant FRP Bridge System 4
  • Refractory class-I material strong acid and alkali-resistant FRP Bridge System 5
  • Refractory class-I material strong acid and alkali-resistant FRP Bridge System 6
Refractory class-I material strong acid and alkali-resistant FRP Bridge

Refractory class-I material strong acid and alkali-resistant FRP Bridge

Ref Price:
get latest price
Loading Port:
Tianjin
Payment Terms:
TT OR LC
Min Order Qty:
600 m
Supply Capability:
200000 m/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Specification

functionality:
anti-corrosion
material quality:
Glass fiber reinforced plastics

    The cable tray produced by the company has a wide range of varieties and specifications, and has more than 30 various production lines,  Over the years, the company's credit rating has reached "AAA", and it has been rated as "Contract-honoring and Promise-keeping Unit" and "Credibility Demonstration Unit in the Metal Plastic Products Industry".

Refractory class-I material strong acid and alkali-resistant FRP Bridge

FRP cable tray is a kind of cable tray produced by pultrusion process. It uses special alkali-free non-twist pultrusion yarn. Cooperate with pultrusion resin to cure at high temperature and continuous pultrusion molding.Refractory class-I material strong acid and alkali-resistant FRP BridgeThe use of special molds has higher accuracy and better uniformity of dimensions.

Refractory class-I material strong acid and alkali-resistant FRP BridgeThe bridge frame adopts split assembly forming. The configuration is more flexible, and convenient to organize production.

Refractory class-I material strong acid and alkali-resistant FRP Bridge

Refractory class-I material strong acid and alkali-resistant FRP Bridge

Refractory class-I material strong acid and alkali-resistant FRP Bridge

Refractory class-I material strong acid and alkali-resistant FRP Bridge

Finished products stacked.Refractory class-I material strong acid and alkali-resistant FRP Bridge

Refractory class-I material strong acid and alkali-resistant FRP Bridge

Refractory class-I material strong acid and alkali-resistant FRP Bridge


Packing details: 

       Suitable for sea transportation, and the strapping is wrapped with a strong steel belt.

 Delivery details: 

       15-30 days after receiving 50% advance payment.

 Production capacity: 

       500,000 meters per year.

 Product implementation standard: 

       Industry standard JB/T 10216-2013 <<Cable tray for electrical control and power distribution>>.

 Side thickness: 

       2-6mm

 Product length: 

       6m/section.

 Origin of FRP raw materials: 

         Shandong Hongxin Model 191.

 Origin of felt cloth: 

         Shandong glass fiber 300 grams per square meter.

 Standard for connecting screws and hooks: 

         304 stainless steel.

 Certification certificate: 

         Quality management system, occupational health and safety management.

 Cover width: 

         According to customer requirements.

 Color: 

         According to customer needs.


Q: Cable tray specifications are generally how to choose
Cable bridge selection design . to determine the environmental conditions Environmental conditions are generally three: corrosive environment, the normal environment, special environment. . according to the majority of cable, in the room can be along the column, beam, floor walk, as far as possible in the process along the pipeline to go. . calculate the load calculation in the cable bridge to the cross section of the unit length of the cable weight q and the total load GG total = n1q1 + n2q2 ... ... nnqn where: q1 q2 q3 ... ... qn for each cable unit weight (kg / M) n1 · n2 · n3 ... nn is the same number of cables G total <G (the allowable load of the cable to the reference load curve chart) . select the bridge according to the cable load and bridge installation of the environment to the bridge Load curve as the basis, to determine the type of bridge and specifications and column spacing, the length of the arm, the bridge level, the length of the column and so on. . according to the cable to the installation and installation of the environment to determine the fixed way of the bridge; hanging, vertical, (these two forms can be used unilateral fixed or bilateral fixed), wall side and so on. . a variety of cables in the cable bridge on the level of arrangement and inter-layer distance. Cable bridge level arrangement is: weak control cable in the top, then the general control cable, low-voltage power cables, high-voltage power cables in order: the following table: This arrangement is conducive to shielding interference ventilation, heat and so on.
Q: What is the angle of the cable bridge climbing angle?
If it is the same style, then the cable protection tube its inner wall may be 2.8mm it, like .20 and the like may be inside the bar.
Q: How to choose cable tray? What is the rough cable to use what size of the bridge? How much margin does the cable tray stay?
outside the set of electric wells, the depth of the bottom of the casing in the 1 meter or so, and the wells do waterproof, wellhead should be hardened around, to avoid rain immersion, you seem to have done, but do not good enough, at the same time Into the built-in automatic suction pump, rain more than a certain depth of automatic drainage, is the price slightly higher; in the cable casing surrounded by water swelling type of water, such as BW Zhishui, etc, but the effect in general
Q: Whether it can be in the bridge under a layer of 60mm polystyrene board, at home 20mm asbestos insulation, insulation layer wide out of the edge of the bridge 200mm? The The Hurriedly ... can you? More
Viewing star - set-top box companion one. To achieve free to watch radio and television digital TV function sluggish rough end Nao stubble full length households two. To achieve two (multiple) TV viewing function three. Free to see the function of value-added program package
Q: Is not the cable bridge, the whole plant laying a flat iron, each layer of equipment to the ground bus to the bridge on the flat iron, rather than on the bridge. Is this the requirement? More
ZR on behalf of the flame retardant properties YJ said cross-linked polyethylene insulation V said PVC jacket ZR-YJV table red copper core XLPE insulated PVC sheathed power cable 4 * 70 + 1 * 35 that 4 core 70mm2 + 1 core 35mm2 fixed this one I do not understand
Q: I am mainly doing street lighting project (including street-powered box-type substation installation), if any specific details of the other prizes, thank you! Question added: Please do my project sub-division, sub-items, inspection batch Tell, must re-thank more
The national standards and industry standards for mining cables are as follows: GB / T
Q: (E-5A-4) is an ideal protective material for the energy industry (nuclear power, petrochemical industry) emergency circuit, cable tray fire separation, and other electrical control systems. More
There are so many cables connected to the top of the elevator box, to the elevator power supply, including control cables, power cables, lighting cables, see below:
Q: What is the difference between a trough bridge and a tray tray?
Upstairs did not understand the meaning of the question. Wire access control box is to set the length of the. The general requirements of the length of the land is not very high, the distribution box is particularly evident, many building distribution boxes are casually put the point line where the spare. Instruments and equipment on the electrical control box is a very high demand. In the line, from the terminal to the outlet hole is generally between the zigzag, tie tie, the length of the reservation line is about 1.5 times the width of the control box (about). This can be convenient after the replacement of components, maintenance and so on. Wiring is not like land with a direct cable access, but there are related technical requirements, such as anti-corrosion, anti-corrosion, and so on.
Q: Do not have a very professional, can mark the specific layout, specifications can be
In the PCB design interface, select the power and ground network in the browser. Then edit the properties. Or set before wiring.
Q: Bridge down the wall down to the distribution box top, how to import distribution box?
VGA wiring method 1R signal 2G signal 3B signal 4 empty 5 empty 6 ground (R) 7 ground (G) 8 ground (B) 9 empty 10 ground 11 self test 12 empty 13 line synchronous (or composite sync) 14 field synchronization 15 Empty This is vga15 pin wiring method, only used to 6 lines, according to the connection you vga line.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches