Phenolic air duct insulation board environment friendly
- Loading Port:
- Xiamen
- Payment Terms:
- TT or LC
- Min Order Qty:
- -
- Supply Capability:
- 80000 m²/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Description:
The Phenolic Foam Preinsulated Duct panel system is the most advanced and inovative energy saving system of centre air-conditioning ductwork available worldwide. The Ductwork is fabricated by using rigid phenolic insulation panels in length of 4m and provide the optimum energy saving and environmental solution in comparison with other types of ductwork. The system consists of Phenolic Pre-insulated Duct Panels, fabrication methods, jointing systems and a complete line of accessories to complete a system.
The Phenolic Foam Preinsulated Duct System is the recoganized leader in new generation pre-insulated ductwork. It offers the triple benefits to cut down the energy, carbon and cost whilst already having proved itself in its highly competitive marketplace. Being based on a phenolic resin it has outstanding fire resistance characteristics and extremely low smoke emission when expose to a flame source.
Parameters:
Item | Unit | Specification |
Panel Structure | Alu./Foam/Painted steel sheet | |
Standard Panel Size | mm | 3950*1200*20 |
Alu. Foil / Painted steel sheet Thickness | mm | 0.04/0.17 |
Foam Density | kg/m3 | 40 |
Thermal Conductivity | w/m.k | 0.02 |
Compressing Strength | Mpa | 0.25 |
Bending Strength | Mpa | 1.2 |
Combustibility Property | Class 0 (BS476 Part 6 & 7) | |
Water Absorption | % | 1.9 |
Max Smoke Density | % | 2 |
Dimension Change | % | 0.3 |
Ambent Temperature | °C | -250- +150 |
Maximum Allowable Wind Velocity | m/s | ≤12 |
Continuous Running Maximum Temperature | °C | ≤70 |
Advantages:
Compared to traditional insulated Sheet Metal Ductwork:
Do it in one time, no lag insulation required, save the labor and cost.
Save the buiding space due to good insulation function
Lightweight, decrease the total weight of building
Decrease air leakage by using flange joint
Low thermal conductivity, no condensation, energy saving
Closed cell foam, good acoustic insulation
Fire-resistance, no smoke when expose to fire
Faced with aluminum foil, it’s water proof and anti-microbial
CFC and HCFC free, environment friendly
- Q: Such as the problem, and now air-conditioning technology is mature, the market a lot of air conditioning are cold and warm, and I would like to be able to put my home that the end of the century loaded Mitsubishi air conditioning (split single cold) into a cold Before the conversion of ordinary TV to the remote control, that air conditioning can be modified? How much does it cost? Where is this technology? More
- So good, then you recommend more. Give an address. You are not layman, too modest.
- Q: Air to water heater host and air conditioning host is not the same
- This test with a small sample length 127mm, width 12.7mm, the maximum thickness of 3.2mm. In the absence of ventilation test chamber. The top of the specimen (6.4 mm place) is clamped with a clamp on the bracket and the longitudinal axis of the specimen is kept vertical. The lower end of the specimen is 9.5mm from the lamp tip and 305mm from the dry absorbent cotton surface. Bring the Bunsen burner and adjust it to produce a blue flame with a height of 19mm. Place the Bunsen Lights flame at the bottom of the sample for 10s, then remove the flame (at least 152mm away from the specimen) and write down the sample. Burning time. If the flame of the sample within 30s after removal of the flame is extinguished, the original lamp must be moved under the specimen again, re-ignite the sample for 10s, and then remove the Bunsen burner again and note the flame burning And flames burning the burning time. If the sample droplets drip, let it fall into the sample under the 305mm cotton, to see whether it ignited cotton. If the absorbent cotton is on fire, the rating should be taken into account. Specific grading indicators are as follows. Test Item 94V-094V-194V-21 Ten-time ignition Total flame burning time Maximum value (S) Individual flame burning time Maximum value (s) Flameless burning time (s) Yes Flame drop No No Allow only short time Burning general UL yellow card on the thickness of the test strip is divided into: 1/8 inch, 1/16 inch, 1/32 inch thickness, that is, 3.2mm, 1.6mm, 0.8mm three grades test.
- Q: Air conditioning ventilation when the sound is a big reason
- No matter, it is best to cut the distance between the material and the roof, like an arbor. Otherwise it is not foam board with it
- Q: Gree air conditioning 50 heating and cooling mechanism heat when the host cooling network is how the matter
- Not the ,,, mobile air conditioning inside the compressor, the winter heating also need the compressor, but also a ventilation pipe, charged heating Well?
- Q: I added the space 18 degrees opened for 5 hours or not cold, we all know how is it? More
- Common points are all sandwich panels, with a hard protective layer, the difference is the middle of the different materials, such as polystyrene board, polyurethane board. Polystyrene board which is the most common, because the price is cheap, easy to use so the use of more, but if the temperature is more than the requirements of the chicken inertia glycosylation moxibustion slim faint words, polystyrene board is not satisfied , So there is a polyurethane sandwich panels, polyurethane thermal conductivity of less than 0.. in the existing insulation materials, large quantities of processing, be the best. But because of its process is more complex, and the cost is relatively high, so with less, the common combination of cold storage and the like, I believe that with the economic and technological development, polyurethane sandwich board market share will be more and more High
- Q: Air conditioning machine work when the sound is too much reason
- Color steel plate, refers to the color coated steel plate, color coated steel plate is a kind of organic coating with steel plate
- Q: What is the whole heat exchange fresh air ventilator?
- Depends on the main control panel is not cold and warm, single cold common motherboard. Only a generic motherboard can be changed. In the single cold air-conditioning on the outdoor machine to install the appropriate specifications of the four-way valve, adjust the amount of refrigerant to the appropriate level can be.
- Q: External wall insulation method of operation There are several combinations of materials
- 30-150 per square meter has, mainly to see the material, thickness and so on
- Q: The installation method of ordinary air conditioner. The more detailed the better. Please thank you all
- The basic operation of the same, but the different requirements of different professional, or to determine the direction of good, and then hands.
- Q: Ventilation is very good, why still have to install fresh air system
- You are a single raft toilet wipes Pie Tanzhuang open card would like to confirm what? Contract notarization or. The The If it is contract notarized, generally notary value of 0.25% -0.3%
Send your message to us
Phenolic air duct insulation board environment friendly
- Loading Port:
- Xiamen
- Payment Terms:
- TT or LC
- Min Order Qty:
- -
- Supply Capability:
- 80000 m²/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords