Perfect Power Output Section

The HIVERT general MV VFD adopts the power cells connected in series and voltage overlapping method (i.e. Power cells multi-level cascade technology), it can output the perfect PWM sinusoidal waveform (see Figure 2 and Figure 3). It has the following advantages:

1. No need for the additional output filter

2. Directly driving general synchronous or asynchronous motor

3. No de-rating operation on the motor

4. No dV/dt stress on the insulation of motor and cables

5. No torque ripple, extending service life of motors and mechanism

6. No cable length restriction within the acceptable voltage drop.

The general MV VFD has the following protection functions and features:

Overload and over-current

Phase loss and grounding

Over voltage

Overheat

Current limit

Redundant control power supply

Cell Bypass (optional)

Cabinet door alarm

Phase-Lock function

Synchronous Switching between VFD and Grid system

Soft start of motor

High efficiency >98% (VFD at full-load)

Electrical Isolation by the optic fiber

Built-in PID regulator

RS485 communication with the protocol, Modbus as standard, optional Profibus-DP, Ethernet,etc

Accurate fault records, easy to check fault history

 Compact structure and layout, customized design is available

Q: The relationship between the power supply of the notebook and the battery
2, when the laptop turns on the power adapter, and the battery power is low, the charging circuit detects the battery power is lower than the set value, the power adapter will side of the host power supply, while the battery charge. After the charge is restored, it is restored to the power supply state directly from the adapter. Therefore, the relationship between the power supply of the notebook and the battery is that the battery is charged by the power adapter when the battery level is below the set value.
Q: Huichuan frequency converter drag a 4-kilowatt four-pole motor to change the six pole can?
Is the inverter must be. Do not know you are also a generic vector. If it is common to directly on the instructions on the motor logarithmic change 6 pole, turn the number changed to 980 on the line. Vector, then change the number of 980 and then learn from the line on the line.
Q: Notebook plug in the power adapter lights, but can not open the machine
Put the board under the re-installed, try and then boot. Asked: This is the case of removal, with the battery can boot answer: Then put the battery on the computer, and then use the power splitter to see if you can. If not I do not know, is the computer question to ask: This can be
Q: Yaskawa inverter reported base blockade what is the reason?
This is the base block command, when the external input block command signal, the inverter will appear this code, the code appears, the motor will be free to rotate, does not affect the use.
Q: How to disassemble the notebook power adapter
3, then open the shell of the power adapter, you can see the adapter circuit outside the package with a copper shield, with a knife to cut the shielding tape on the tape, and then use the soldering iron shield and the internal circuit board connected to the two Solder joints, you can remove the shield.
Q: Inverter problem
A: The inverter output 4 ~ 20mA (0 ~ 20mA), the analog signal can be directly connected to the measuring instrument, the daily design, installation, application are so, as long as the selection is correct, there will be no problem.
Q: With the inverter control fan 37Kw4 pole with what model inverter
If the speed is not very high requirements, all the general-purpose inverter can be.
Q: Old printing machine transformation, 37KW6 polar frequency motor with brake, inverter 55KW, now found running,
May be mechanical part of the card, try idling motor.
Q: Inverter principle eff23
For vectors such as vector-controlled frequency converters that require a lot of computation, there is sometimes a need for a torque calculation CPU and some corresponding circuits. Frequency control is by changing the motor stator winding power supply to achieve the purpose of speed.
Q: What is the output voltage of the laptop power adapter?
Laptop power adapter output voltage, different brands may be different. Adapter output voltage is not a unified standard, different models are not the same notebook. The output voltage between 12V to 20V, 19V, 20V more.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords