• LFP Battery Energy Storage System SLA60 Power 60W SLA60 Charge 5V 12V~18V Electronic Devices System 1
  • LFP Battery Energy Storage System SLA60 Power 60W SLA60 Charge 5V 12V~18V Electronic Devices System 2
LFP Battery Energy Storage System SLA60 Power 60W SLA60 Charge 5V 12V~18V Electronic Devices

LFP Battery Energy Storage System SLA60 Power 60W SLA60 Charge 5V 12V~18V Electronic Devices

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
10 unit
Supply Capability:
10000000 unit/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

LFP Battery Energy Storage System Power 60W SLA60 Charge 5V 12V~18V Electronic Devices

SLA60


Charge 5V electronic devices such as mobile phones, tablets, mobile power supplies, PSP, MP4, GPS,Bluetooth headsets under sunlight; charge 12V~18V electronic devices such as car starter power supplies,laptop mobile power supplies, emergency energy storage power supplies



  • Product Description

  • Specification parameters

    Packaging technology

    Aminate technology

    Packaging materials

    EVA/ETFE

    Solar Cell Type

    Monocrystalline silicon

    Power

    60W

    Conversion rates

    ≥20%

    Voc

    >23.76V

    Vm

    >19.8V

    lsc

    >3.33A

    Im

    >3.03A

    Open dimension

    1006*461*5mm

    Folded dimension

    461*284*35mm

    Weight

    1.5kg


FAQ

CFE Lithium-ion Battery




Q: What kind of battery you can provide?

A: a.12.8V-25.6V 30Ah/40Ah/50Ah/100Ah//200Ah LFP battery for replacement of Lead-acid/Gel battery.

    b. 51.2V 50Ah/100Ah LFP battery module for residential energy storage with cube (10,15,20 kwh).

    c. Solar hybrid inverters with power 4,5,6,8,10,12kw, solar off grid inverter 3,5 kw.

    d. Inverter & Battery ALL IN ONE, with capacity 5,10,15,20 kwh.

    e. E-mobility battery for E-scooter, E-bus, E golf cart etc.(Rank Top 3 in China).

    f. 48V 50A/100AH/150AH/200AH LFP Battery for Telecom-towers.


Q: What is the capacity of production?

A: CFE has 13 production lines with a total capacity of 12Gwh for both storage and E-mobility.


Q:How long is the warranty period?

A: Our limited warranty is valid for a period 5 years (12.8V products) /10 years (51.2V products) after delivery. It is restricted by specifications and warranty terms.


Q: How long is the estimated delivery time?

A: The delivery time is within 25 days after receiving the payment.


Q: Are you able to handle shipment transportation?

A: We can arrange the shipment to most places as required.


Q: What kind of certification do you have?

A: We have SGS, TÜV, IEC 62040-1, IEC 62109-1, IEC 62109-2, IEC 62619, UN38.3, IEC 62133, CEC, UL, MSDS, ISO 9001 certifications, but each product may be different.


Q: What kind of product quality your factory offer?

A: We provide the most competitive products at the highest quality. (100% cell sorting test under inner resistance ≦2mΩ, voltage differ ≦ 2mV,100% EOL test, 100 % aging, 100% final product testing) .


Q: Can we print our logo on products?

A: We can provide one to one customized OEM with a MOQ demand.


Q: What is the validity of the quotation?

A: Due to the raw material price fluctuation, the quotation validity is 10 days.


Q: What is the difference between a maintenance-free battery and a conventional battery?
Different materials will produce a different phenomenon: the traditional battery in the course of the use of the phenomenon of liquid reduction occurs, because the antimony on the grid will pollute the sponge on the negative plate of pure lead, weakened after the full charge of the battery Electromotive force, resulting in excessive decomposition of water, a large number of oxygen and hydrogen, respectively, from the positive and negative plates to escape, so that the electrolyte reduced. With calcium instead of antimony, you can change the fully charged battery back electromotive force, reduce the overcharge current, liquid gasification rate decreases, thereby reducing the loss of electrolyte.
Q: How to deal with waste batteries?
The old battery is ground and then sent to the furnace for heating, then the volatile mercury can be extracted, the temperature is higher when the zinc is also evaporated, it is also precious metals. Iron and manganese fusion after the steel to become the required ferromanganese alloy.
Q: What are the hazards of battery over discharge?
When the battery discharge current is large, the heat will become more obvious, there will be serious heat generated when the battery deformation, when the concentration of lead sulfate is particularly large, will form a larger crystal particles, that lead to the battery Internal irreversible sulfation.
Q: Maintenance-free battery how to detect it?
Battery pole Pole terminal has corrosive material without treatment, as long as no loose on it. If the appearance of the corrosive material, the inner surface of the terminal will also be corrosion, resulting in increased resistance, affecting the normal battery charging and discharge, it must be promptly processed.
Q: What battery does the van use?
The most obvious feature of lead-acid batteries is the top of the plastic cover can be unscrewed, there are ventilation holes above. These fillers are used to fill pure water, check the electrolyte and the use of exhaust gas. In theory, lead-acid batteries need to check the density of each electrolyte and the level of liquid, if there is a need to add distilled water. But with the upgrading of battery manufacturing technology, lead-acid battery development for the lead-acid maintenance-free batteries and colloidal maintenance-free batteries, lead-acid batteries do not need to add electrolyte or distilled water. Mainly the use of positive electrode to produce oxygen can be absorbed in the negative oxygen cycle, to prevent water reduction. Lead-acid water batteries are mostly used in tractors, tricycles, car start, etc., and maintenance-free lead-acid battery wider range of applications, including uninterruptible power supply, electric vehicle power, electric bicycle batteries. Lead-acid batteries according to the application needs to be divided into constant current discharge (such as uninterruptible power supply) and instantaneous discharge (such as car to start the battery).
Q: How should the battery be well maintained?
So the proposed owners if the vehicle long-term stop, but also 2 to 3 months for the battery for a charge.
Q: The role of the battery?
It filled with lead plate filled with sponge lead as a negative electrode, filled with lead dioxide lead dioxide as a positive electrode, and with 22 to 28% dilute sulfuric acid as electrolyte. In the charge, the electrical energy into chemical energy, the discharge of chemical energy and into electrical energy.
Q: What kind of battery is divided into?
At present, we used the car battery is divided into three categories, namely, ordinary batteries, dry batteries and maintenance-free batteries three.
Q: Battery 200ah / 104 what does that mean?
This should be refers to 2V200AH battery 104, power with the 220V. Lead-acid battery nominal voltage is 2V / (each or monomer), but in fact will be higher than 2V, so the actual use and charging equipment for the matching will use 104, also useful 103, also useful 108 Only.
Q: How does battery activation work?
If you are talking about dry batteries, that is, to add sulfuric acid can use the battery (commonly known as water bottles), then it is because the long-term storage so that a high degree of oxidation of the negative board, plus acid will be a high temperature, Low, you can add acid in the pool after the addition of a small current for a long time to charge, you can solve. Generally with 0.05C charge to 3 times can be.

Send your message to us

This is not what you are looking for? Post Buying Request