• High Voltage Frequency Drive 10KV 500KW  VFD System 1
  • High Voltage Frequency Drive 10KV 500KW  VFD System 2
High Voltage Frequency Drive 10KV 500KW  VFD

High Voltage Frequency Drive 10KV 500KW VFD

Ref Price:
get latest price
Loading Port:
Tianjin
Payment Terms:
TT OR LC
Min Order Qty:
1 unit
Supply Capability:
100000 unit/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Specifications

1.Higher torque in low speed
2.More smooth & stable running no resonance
3.Low temperature rise, higher effeciency

BPT series frequency conversion speed regulator is your best choice for flux control air fan, water pump and compressor. This product can meet all kinds of demands, operation modes and complete protection functions.

Features:
1 Advanced space voltage vector control technology, much better than traditional wave control technology:
1.1 Higher torque in low speed;
1.2 More smooth & stable running, without resonance;
1.3 Low temperature rise, higher effeciency.
2. Perfect protection system design
Special short protection technology can assure release when short and earth(ground) fault happened.
3. Long longevity
The max. Temperature rise is 20º C that can prolong the service life.

Working condition
Upper limit of ambient temperature is no more than +50º C;
The relative humidity is no more than 85 percent. The height above sea level is no more than 2000m;
It should be placed on an indoor place without obvious shake and impact, without fire and explosive dangers and the vertical gradient is no more than 5º ;
There must be no conductive dust and corrosive gas.

 

Specification

 

Model

A03/050~
A03/100

A03/100~
A03/175

A03/175 ~A03/220

A03/220~A03/400

A03/220~A03/610

Capacity(kVA)

250~630

630~900

900~1150

1150~2000

2000~3125

Rated output current (A)

50~100

100~175

175~220

220~400

400~610

Motor power (kW)

200~400

400~710

710~900

900~1600

1600~2500

Input frequency

45Hz~55Hz

Rted input voltage

3000V±10%

Input power factor

0.95 (>20%load)

Efficiency

0.96 with rated load

Output frequency

0.5Hz~120Hz

Frequency resolution

0.01Hz

Overload capacity

120% 1 min, 150% immediately

Analogue input

0~10V/4~20mA

Analogue output

0~10V/4~20mA

Acceleration/deceleration time

0.1~3000s

Digital output/input

expanded according to requirement

Ambience temperature

0~40°C

Storage/transport temperature

-40~70°C

Cooling

air cooling

Ambience humidity

<90% without condensation

Altitude

<1000 m

IP class

IP20

Size(mm)(W×H×D)

3300×2480×1200
3900×2480×1200

4900×2480×1200
6000×2580×1200

6000×2580×1300

Weight (kg)

3000 ~5000

5000 ~7300

7300~9200

 

Q:My Lenovo v450 laptop power adapter should be bad how to match?
Hello, this is not recommended to go online to buy. The original is too expensive, generally with the domestic voltage instability may occur, so I suggest you go to the computer city to buy. Generally good quality, to about 120. The The As for the model, you can look at the output power, or you take your bad adapter to go, people see a look. The The The You can use a few years no problem, power adapter this kind of thing, online to buy the replacement is not convenient. The Hope to help you
Q:5.5 kW 4-pole motor with the fastest speed can exceed the rated speed?
Because the frequency converter can reach 60 Hz frequency, while the three-phase power supply is the standard 50 Hz. So the inverter can make the motor speed faster than the rated 1500 rpm. The fastest up to about 1800 turn.
Q:The inverter control power is also the same, the pole is not the same as the motor 6 or 4 pole can be used?
Can be used, but is being used in the motor replacement, you need to change the frequency conversion.
Q:18: 5 kilowatts bipolar multi-pole pump motor with inverter
If you worry about the small, with 18.5KW is far enough.
Q:What is the meaning of the bipolar polarity in the inverter ah There is a +10V signal input is a -10V What is the meaning of ah?
That is to say that the potentiometer at both ends of the line between + 10v and -10v, tap can be given with a potentiometer to control the positive and negative!
Q:Is the number of Amps of the notebook power adapter higher than the original number of security on the computer?
The current amperage of the power adapter is only experienced at its maximum output power, as long as the power adapter output voltage and your original no problem. For example, when the home circuit from the power supply into the terminal does not limit the size of the current, but to provide a fixed voltage. The more your household appliances, the greater the current through the power supply into your home. And the indoor air break switch is a current limit, this is based on the ability to accept the wire. From the point of view of the meter, you use the power equal to UIt = W, where UI is the voltage and current, two multiplication is equal to power, power multiplied by time equal to power consumption. Say back to your power adapter, the power adapter output voltage is rated, as long as this notebook with your original output voltage is the same as your notebook will not hurt. And the power adapter current is the maximum output, the consciousness is the power adapter output maximum power P will not exceed this value, usually 65W or 90W. Greater than the power of such a computer can not be stable operation. Or a physical point of view, the use of notebook power adapter, in fact, the internal is a number of parallel circuits, secondary knowledge tells us the voltage of the parallel circuit at any end are the same size, and parallel devices, the greater the total current in the circuit The
Q:Who knows how the frequency converter works
3. Control circuit Now the basic converter with 16-bit, 32-bit microcontroller or DSP as the control core, in order to achieve full digital control. The frequency converter is the output voltage and frequency adjustable speed control device. The circuit that provides the control signal is called the main control circuit. The control circuit is composed of the following circuits: "operation circuit" of frequency and voltage, "voltage and current detection circuit" of main circuit, and "speed detection circuit" of motor. The control signal of the operation circuit is sent to the "drive circuit" and the "protection circuit" of the inverter and the motor Inverter to take the control mode, that is, speed control, turn control, PID or other means
Q:Fuji inverter motor set the number of poles will not have any effect?
The number of poles is not the same as the speed is not the same mistake machine can not work or motor coil burned
Q:How to choose a power adapter
Your notebook power part of the compatibility is very good, in a certain voltage range of power can be used long, but still please note on the notebook subject.
Q:How to make the motor speed (control speed), can not use frequency
In general, the torque generated by the motor is reduced with decreasing frequency (decrease in speed), and the reduced actual data is given in some frequency converter manuals. By using the flux vector control of the inverter, will improve the motor at low speed torque, even in the low speed area motor can also output enough torque. When the frequency converter to speed up to 60Hz frequency, the motor output torque will reduce the normal motor is designed to 50Hz (60Hz) voltage, the rated torque is given in this voltage range. So the rated frequency under the speed is called constant torque speed, the inverter output frequency is greater than 50Hz frequency, the motor torque to be inversely proportional to the frequency of the relationship between the decline. When the motor is running at a frequency greater than 60 Hz, the magnitude of the motor load must be taken into account to prevent the motor output torque from being insufficient. For example, when the torque generated by the motor at 100 Hz is about to be reduced to about 50 Hz, the torque is generated. So the rated frequency above the speed is called constant power speed.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Related keywords