High Quality Pneumatic Double Stations Heat Press Machine

Ref Price:
Loading Port:
China Main Port
Payment Terms:
TT or LC
Min Order Qty:
1 Set set
Supply Capability:
2500 Sets Per Month set/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Packaging & Delivery

Packaging Details: wooden package
Delivery Detail: depends on order

Specifications

pneumatic double stations heat press machine

1.CE approved

2.High pressure transfer machine

3.10+ Years Professional

Feature:

♦ Two work tables

♦ Auto open, large format

♦ Digital Temperature & Time Control

♦ Automatic Alarm

♦ 1 year warranty on entire press

♦ Wooden Package

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:About the elevator parts, up and down through, how this part of the heat load calculation
Specification specified, adjacent room temperature is greater than or equal to 5 ℃, or through the partition wall and slab in heat transfer is greater than 10% of the heat load of the room, should be calculated through the partition wall or floor heat transfer, heat transfer heat consumption calculation formula to calculate the reference maintenance structure. The specification says facing correction rate, should consider the local winter relative sunshine duration, construction use and bai shade, and so on and so forth. In winter relative sunshine duration is less than 35% of the region, southeast, southwest and south to fix rate, appropriate USES - 10% ~ 0, to the east, and west is not fixed. If you describe, sunshine is obscured, are refer to the above description. Standard correction not only say, north and south, east and west four directions, suggest to scrutiny.
Q:Thermal equipment fouling and slagging what's the harm?
After thermal equipment fouling, often caused by poor heat transfer tube wall temperature, when the temperature exceeds the metal can allow temperature, it could cause bulge and pipe explosion accidents. Water boiler water slag is too much, can affect the boiler steam quality, and perhaps blocking furnace tube, threatening the safe operation of boiler.
Q:Carbon steel, stainless steel, copper heat transfer effect
The heat transfer effect is best copper, stainless steel, carbon steel finally
Q:What are heat exchange equipment
Plate heat exchanger used in between two or more fluid, a kind of fluid and solid particles or between a solid and thermal contact between the same kind of fluid with different temperature of heat (or enthalpy) transfer device called a heat exchange equipment. It is the chemical industry, oil refining, food, light industry, energy, medicine, machinery and many other industries are widely used a kind of general equipment.
Q:There are several kinds of electrode drying equipment heat transfer
Namely on the one hand, calculation of different equipment investment costs; On the other hand, because of using new equipment to improve labor productivity, save energy consumption and ensure the quality of products and form the savings of the search, such as payback period according to the investment costs and savings calculation.
Q:What is the difference between diversion in heat exchanger heat exchanger and diversion?
In diversion tube heat exchanger is inside the shell side of heat exchanger tube set up within the guide tube make the before or after the end of the heat exchanger without diverting tube before use hard to make full use of the heat transfer of heat exchange tube, thereby increasing the effective heat transfer area of heat exchanger. Hypoxia or diversion tube used in fixed tube plate heat exchanger, and less common in the u-tube heat exchanger. Flow heat exchanger was increased on the shell side of heat exchanger in the original cylinder a zoom cone section presents to the diffusion of shell side fluid, and makes the fluid from the ends of the heat exchanger shell side into the shell side, avoiding the consider cloth tube in heat exchanger tube arch is high, and the increased number of cloth tube heat exchanger with norms and effective utilization of the heat exchanger before and after the heat exchange tube so as to increase the effective heat transfer area. Outside the diversion tube commonly used in the fixed tube plate heat exchanger, and in the u-tube heat exchanger and floating head heat exchanger is not common Diversion tube inside and outside the diversion tube flush function point of view is the same, all is in order to increase the effective heat transfer area of the heat exchanger. But tell from the purpose, the latter to the former than the latter in the fixed tube plate heat exchanger can increase the amount of cloth tube heat exchanger. As heat exchanger equipment can be seen everywhere, very popular in the industry, especially in energy consumption is very large areas, with the rapid development of energy-saving technology, heat exchanger type development more and more. Suitable for different medium. Different condition, different temperature and pressure of heat exchanger, the structure and pattern are also different.
Q:Iron heating tube, quartz heating tube who fast heat conduction
Heating speed refers to only a few meters dozens of seconds or a few minutes, if the heating time more than ten minutes, half an hour or more, or suggest use metal pipe, iron pipe than stainless steel heating tube of low cost, but if no rust bad back for a long time, if have been use the low cost or iron pipe
Q:When IGBT coating thermal conductive silicone, how did the general daub the ideal
Hello, we provide professional IGBT module coating thermal conductive silicone a full range of solutions, IGBT stencil making, IGBT coating thermal conductive rubber equipment, have success for pv, subway, railway system successful experience etc
Q:What iscalled cooler closed?Is used in cooling water temperature and adding vacuum pump work in the refrigeration system
Retrofit scheme is rod baffle heat exchanger instead of vertical bow plate heat exchanger, without changing the original shell heat exchanger, only change the heat exchanger tube core, is still the vertical installation. Shell side fluid adapted the aspirant, accessory equipment and pipe interface are the same. Heat exchange tube from d19mm x 1 mm brass tube replacement d19mm x 2 mm into boiler seamless steel tubes. Transformation technical agreement requirements, unit with full load, water temperature not less than 21 ℃, modified heater performance test data and calculated results are shown in table 2
Q:Please specify in heat transfer equipment, scale, the existence of the gray scale of the effects of heat transfer process
Scale compared to metal, is a poor conductor of heat, can reduce the heat transfer efficiency.
As a leading manufacturer, all Microtec products are fully assembled by our state of the art manufacturing facility prior to shipment and released only after extensive testing and inspection by our qualified technicians, maintaining the strictest quality control procedures.Our mission is to be a world supplier of Heat Transfer Products and Consumables. We are committed to the principal of satisfying customer and market demands, pursing scientific administration and superior quality by using the latest technology grounded in a thorough understanding of the end-user's needs.

1. Manufacturer Overview

Location Guangdong,China
Year Established 2007
Annual Output Value
Main Markets 7.69% North America
7.69% South America
7.69% Eastern Europe
7.69% Southeast Asia
7.69% Africa
7.69% Oceania
7.69% Eastern Asia
7.69% Western Europe
7.69% Central America
7.69% Northern Europe
7.69% Southern Europe
7.69% South Asia
Company Certifications ISO 9001:2008;SGS; CE

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port Shenzhen,Guangzhou,Zhuhai
Export Percentage 81% - 90%
No.of Employees in Trade Department 11-20 People
Language Spoken: English, Chinese
b)Factory Information  
Factory Size: 5,000-10,000 square meters
No. of Production Lines 6
Contract Manufacturing OEM Service Offered Design Service Offered Buyer Label Offered
Product Price Range Average