Corrugated Aluminium Tape armored 144 core Optical fiber communication cable
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1000 m
- Supply Capability:
- 10000 m/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Quick Details
Place of Origin: | Brand Name: | Model Number: | |||
Number of Conductors: | ≥ 10 | Application: | Aerial, Duct | Certificate: | ISO9001 TLC ROHS |
Fiber type: | G652D | Fiber Count: | 2-288 | Fiber: | single mode |
Material of jacket: | HDPE/LSZH sheath/flame retardant sheath/anti-rodent sheath | Armored: | Aluminium tape/Steel Tape | Tube: | Loose tube stranded/SZ stranded |
Bending Radius: | Static 10*Cable-diameter: Dynamic 20*Cable-diameter |
Packaging & Delivery
Packaging Detail: | Pure wooden drum package, lengths on special request |
Delivery Detail: | within 10 days |
Corrugated Aluminium tape armored 144 core Optical fiber communication cable
Product Description
GYTA optical fiber communicaton cable is an outdoor communication optical cable of metal strength member of the loose tube jelly-filled structure with Al-polyethylene laminated sheath. The loose tubes are made of high modulus plastics (PBT), which are filled with water resistant filling gel and stranded around a metallic central strength member. Cable core is filled with filling compound. A corrugated aluminum tape is longitudinally applied over the cable core, and extruded with a durable polyethylene (PE) sheath.
Features and Benefits
Full cross-section water-blocking structure and double-sided coated film steel belt longitudinal application ensure good water blocking and moisture resistance.
Loose tube is filled with special grease to ensure good water blocking and moisture performance
The phosphate wire center stiffening member is of high modulus and corrosion resistance. More than 30 years of service life.
Applications :
Long haul and building network communication
Installation:
Duct/ Aerial
Bend radius:
static 10x cable diameter
Dynamic 20x cable diameter
Structure and Technical Specifications
Fiber Count | Nominal Diameter (mm) | Nominal Weight (kg/km) | Max Fibers per Tube | No. of (Tubes+fillers) | Allowable Tensile Load (N) | Allowable Crush Resistance (N/100mm) | ||
Short Term | Long Term | Short Term | Long Term | |||||
2~30 | 9.7 | 90 | 6 | 5 | 1500 | 600 | 1000 | 300 |
32~36 | 10.3 | 109 | 6 | 6 | 1500 | 600 | 1000 | 300 |
38~60 | 10.8 | 119 | 12 | 5 | 1500 | 600 | 1000 | 300 |
62~72 | 11.5 | 145 | 12 | 6 | 1500 | 600 | 1000 | 300 |
74~96 | 13.5 | 175 | 12 | 8 | 1500 | 600 | 1000 | 300 |
98~120 | 14.8 | 209 | 12 | 10 | 1700 | 600 | 1000 | 300 |
122~144 | 16.6 | 249 | 12 | 12 | 2000 | 600 | 1000 | 300 |
146~216 | 16.7 | 254 | 12 | 18 (2 layers) | 2000 | 600 | 1000 | 300 |
218~288 | 19.0 | 325 | 12 | 24 (2 layers) | 2500 | 600 | 1000 | 300 |
Note:
1. For flame retardant cable, outer sheath can be made of low-smoke halogen-free (LSZH) material, and the type is GYTZA.
2. The outer sheath with longitudinal color strip convenient for identification and maintenance in the one routing can be provided on customer’s request. The color can be selected based on customer’s request, and bright color (such as yellow, green and red) can be proposed. The GYTZA type is not included.
3. Special cable structure can be designed and manufactured on the customer’s request.
We produce and test cable comply with following standard:
Mechanical Performance | |
Max Tension Performance | IEC 60794–1-2-E |
Max. Operation Tension | IEC 60794–1-2-E1 |
Crush Test | IEC 6079 –1-2-E3 |
Impact Test | IEC 60794–1-2-E4 |
Repeated Bending | IEC 60794–1-2-E6 |
Torsion Test | IEC 60794–1-2-E7 |
Cable bend | IEC 60794–1-2-E11A |
Attenuation Coefficient | ITU-T G.652 |
Structural Test | IEC-60793-1-20 |
Environmental Performance | |
Temperature Cycling | IEC 60794–1-2-F1 |
Water Penetration | IEC 60794–1–2-F5B |
Filing Compound Flow | IEC 60794-1-E14 |
- Q:Decoration when the purchase of water pipes, wires and other items included in the account
- Outdoor fire line must use fire-resistant KVV cable, wear pipe protection.
- Q:I would like to ask my new workshop power consumption of about 500KW, injection molding machine, 60KW . 40KW . 20KW . the other 20KW, how much should the wire? Respectively how to use lines and switches more
- No way to save money! Moreover, the signal to you there, almost all attenuation finished.
- Q:If you want to sell wire and cable, then what to do in advance to detect? The The The The The
- If you use the color component output, you have to have the color difference component interface. With the color line facing the same color on the line. AV line of the yellow plug is the video, red and white is the audio delay Han silhouette cellar jealous of the tea, according to the same color received TV
- Q:IPadmini. The latest version 7.1.1 up in the morning to see the non-stop display this cable is not certified does not support this feature. The The Charger original. Not on the computer charge. The Ask God to answer more
- The problem lies in the charger between the machine, IPAD charging is to a charging protocol to complete, when the IPAD did not receive the agreement signal will be prompted: do not support this accessory, Apple's products have charging protocol, charging Is through the data line in the two lines and IPAD transmission charging protocol signal when ipad received the charging protocol signal after the machine internal charging circuit began to open the internal charging circuit to charge, the problem is to accept the charge signal is not so prompted not to Support, change the line to try
- Q:How to determine how much wire and cable should be used, the current load and how the corresponding wire, such as 4BV, under what circumstances, YJV240 what circumstances, the load is much more
- According to the control cable and the power of the different layers of laying, if the power cable to be multi-layer need to have 300mm spacing (or load capacity is large enough), if it is control cable, casually laying, if the laying of power cable laying below Layer, above the laying of control cable, but not too much affect the power cable cooling. If the high-voltage cable and low-voltage cable in principle do not allow common laying.
- Q:What is the difference between wires and cables?
- The introduction of the device is to introduce the cable into the electrical equipment, without changing the explosion-proof type of explosion-proof equipment
- Q:Why does the bird stand on the wire without anything, but if people touch it,
- Is not the home of the bus box? Generally put a cat, a router, a power outlet, two transformers, the other is the network cable and telephone, the key space to be enough
- Q:Rt, the charger did not change, has been no problem before, today just plugged into the charger, the results appear as if the problem, before the out of this problem, and now only ipad power off after the power can not be charged, and ipad start , Then immediately prompted the title, can not charge more
- The proportion of the cross-sectional area of the cable through the embedded pipe is 20%
- Q:Wire and cable model ZD what does it mean
- Wire pipe water problem: In fact, this problem is very serious, then this line should be scrapped or replaced, if you continue to reluctantly use not only to bring you the safety of trouble and the insulation of the wire dropped sharply! Because there is water it will lead to internal leakage can also make the wire heat caused by wire burning and trivial trivial accident, so be sure to take the necessary replacement! Supplement: the wire out of all, with the wire to grab the absorbent gauze and the like back to the twitching, many times for the gauze to dry the water, hair dryer toward the tube to heat the tube to dry and then re-layout of the new line.
- Q:This cable or accessory has not been certified and may not be able to work with this iphone reliably
- The operation of the hydraulic pipe is very simple to see it will engage in their own, embedded more simple, and then get the construction site in accordance with the requirements of the drawings put away, tied with tie wire on the OK Mouth up the pipe to use cement bag to prevent good, to prevent the infusion of concrete, so buried even if the end
1. Manufacturer Overview |
|
---|---|
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
Corrugated Aluminium Tape armored 144 core Optical fiber communication cable
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1000 m
- Supply Capability:
- 10000 m/month
OKorder Service Pledge
OKorder Financial Service
Similar products
New products
Hot products
Related keywords