Corrugated Aluminium Tape armored 144 core Optical fiber communication cable
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1000 m
- Supply Capability:
- 10000 m/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Quick Details
Place of Origin: | Brand Name: | Model Number: | |||
Number of Conductors: | ≥ 10 | Application: | Aerial, Duct | Certificate: | ISO9001 TLC ROHS |
Fiber type: | G652D | Fiber Count: | 2-288 | Fiber: | single mode |
Material of jacket: | HDPE/LSZH sheath/flame retardant sheath/anti-rodent sheath | Armored: | Aluminium tape/Steel Tape | Tube: | Loose tube stranded/SZ stranded |
Bending Radius: | Static 10*Cable-diameter: Dynamic 20*Cable-diameter |
Packaging & Delivery
Packaging Detail: | Pure wooden drum package, lengths on special request |
Delivery Detail: | within 10 days |
Corrugated Aluminium tape armored 144 core Optical fiber communication cable
Product Description
GYTA optical fiber communicaton cable is an outdoor communication optical cable of metal strength member of the loose tube jelly-filled structure with Al-polyethylene laminated sheath. The loose tubes are made of high modulus plastics (PBT), which are filled with water resistant filling gel and stranded around a metallic central strength member. Cable core is filled with filling compound. A corrugated aluminum tape is longitudinally applied over the cable core, and extruded with a durable polyethylene (PE) sheath.
Features and Benefits
Full cross-section water-blocking structure and double-sided coated film steel belt longitudinal application ensure good water blocking and moisture resistance.
Loose tube is filled with special grease to ensure good water blocking and moisture performance
The phosphate wire center stiffening member is of high modulus and corrosion resistance. More than 30 years of service life.
Applications :
Long haul and building network communication
Installation:
Duct/ Aerial
Bend radius:
static 10x cable diameter
Dynamic 20x cable diameter
Structure and Technical Specifications
Fiber Count | Nominal Diameter (mm) | Nominal Weight (kg/km) | Max Fibers per Tube | No. of (Tubes+fillers) | Allowable Tensile Load (N) | Allowable Crush Resistance (N/100mm) | ||
Short Term | Long Term | Short Term | Long Term | |||||
2~30 | 9.7 | 90 | 6 | 5 | 1500 | 600 | 1000 | 300 |
32~36 | 10.3 | 109 | 6 | 6 | 1500 | 600 | 1000 | 300 |
38~60 | 10.8 | 119 | 12 | 5 | 1500 | 600 | 1000 | 300 |
62~72 | 11.5 | 145 | 12 | 6 | 1500 | 600 | 1000 | 300 |
74~96 | 13.5 | 175 | 12 | 8 | 1500 | 600 | 1000 | 300 |
98~120 | 14.8 | 209 | 12 | 10 | 1700 | 600 | 1000 | 300 |
122~144 | 16.6 | 249 | 12 | 12 | 2000 | 600 | 1000 | 300 |
146~216 | 16.7 | 254 | 12 | 18 (2 layers) | 2000 | 600 | 1000 | 300 |
218~288 | 19.0 | 325 | 12 | 24 (2 layers) | 2500 | 600 | 1000 | 300 |
Note:
1. For flame retardant cable, outer sheath can be made of low-smoke halogen-free (LSZH) material, and the type is GYTZA.
2. The outer sheath with longitudinal color strip convenient for identification and maintenance in the one routing can be provided on customer’s request. The color can be selected based on customer’s request, and bright color (such as yellow, green and red) can be proposed. The GYTZA type is not included.
3. Special cable structure can be designed and manufactured on the customer’s request.
We produce and test cable comply with following standard:
Mechanical Performance | |
Max Tension Performance | IEC 60794–1-2-E |
Max. Operation Tension | IEC 60794–1-2-E1 |
Crush Test | IEC 6079 –1-2-E3 |
Impact Test | IEC 60794–1-2-E4 |
Repeated Bending | IEC 60794–1-2-E6 |
Torsion Test | IEC 60794–1-2-E7 |
Cable bend | IEC 60794–1-2-E11A |
Attenuation Coefficient | ITU-T G.652 |
Structural Test | IEC-60793-1-20 |
Environmental Performance | |
Temperature Cycling | IEC 60794–1-2-F1 |
Water Penetration | IEC 60794–1–2-F5B |
Filing Compound Flow | IEC 60794-1-E14 |
- Q: What brand of cable is good, what are the top ten brands of wires?
- If you are talking about the three-core wire, black - ground brown - line of blue - zero line. If it is 3 plugs, your wire is only 2 lines. Then the yellow received L, black received N. The above is the ground wire.
- Q: The data line is my online to buy the extension of the line, has been able to use, and today suddenly can not charge the electricity, and pop up the tips, which is why? More
- Power lines tied together, usb line bundled together, high and low pressure apart. Tie the tie on the line
- Q: IPadmini. The latest version 7.1.1 up in the morning to see the non-stop display this cable is not certified does not support this feature. The The Charger original. Not on the computer charge. The Ask God to answer more
- Ipad charge display does not support the general reasons for this and processing methods: . for non-original charger, it will often appear this situation, which is due to the charger does not meet the specifications caused by the replacement of a qualified charger can be. . if the original charger appears the above failure, please continue to look down. . please check whether the data line is normal. The appearance of the data lines seem normal, which may have been broken. Check the method is to borrow someone else's data line to see if it can charge. . shows the plug symbol is normal is full of display. If full or show the lack of electricity, indicating that the phone tail no problem. . again, check whether the original charger can work properly. You can connect the charger to other USB port to see if the phone is working properly. . if the above two check still can not charge, please try to insert the computer's USB port to see if the computer can identify the phone, to identify if it is to see if the charge, if not identified but not charged, it is estimated that the need for maintenance. If you can not identify can not charge, it is necessary to repair. If you can recognize and charge, replace the data cable and the charger (the original estimate is also damaged). . and then look at the voltage is not too low, not only to the maintenance station to repair, and pay attention to the iPad and iPhone do not mix the power adapter, the voltage is different.
- Q: Rt, the charger did not change, has been no problem before, today just plugged into the charger, the results appear as if the problem, before the out of this problem, and now only ipad power off after the power can not be charged, and ipad start , Then immediately prompted the title, can not charge more
- Budget 1W5 requires the whole machine to include the display of the monitor not too big too much Not used to more
- Q: Cable a fire line power and why the other did not pick up the line with a pen test also have electricity? Answer detailed point
- Megohmmeter, such as measuring insulation normal, that is, induction power, the other line after grounding, the pen measured no electricity.
- Q: What is the difference between "wire" and "cable"?
- Simple point, the plotter is generally used to out of the line map, the general is the Academy of Engineering, the Bureau of the use of a CAD map, and some can also be some effect of the general effect of the map, generally suitable for color requirements are not very high, but right Print accuracy requires a high place. Inkjet machine can be divided into indoor and outdoor ink, outdoor irritating smell, for outdoor advertising like the effect of the map, the indoor no irritating smell, the general subway, as well as other indoor advertising are used this out of
- Q: IPhone6 This cable or accessories have not been certified how to solve
- The color is easy to distinguish. General yellow on behalf of the video line, red white plug left and right audio.
- Q: Wire and cable model ZD what does it mean
- Wire pipe water problem: In fact, this problem is very serious, then this line should be scrapped or replaced, if you continue to reluctantly use not only to bring you the safety of trouble and the insulation of the wire dropped sharply! Because there is water it will lead to internal leakage can also make the wire heat caused by wire burning and trivial trivial accident, so be sure to take the necessary replacement! Supplement: the wire out of all, with the wire to grab the absorbent gauze and the like back to the twitching, many times for the gauze to dry the water, hair dryer toward the tube to heat the tube to dry and then re-layout of the new line.
- Q: What are the varieties of wire and cable (detailed point)
- (The difference between the two cables: WDZ and WDZC are the combustion characteristics of the cable, both halogen-free low smoke flame retardant cable, but the former is a single vertical flame retardant test, which is bundled combustion C class flame retardant Test, but the flame retardant performance requirements are not the same. The meaning of the letter: W refers to the halogen-free; D refers to the low smoke; Z refers to the flame retardant WDZ is halogen-free low smoke flame retardant jacket power cable. WDZC refers to halogen-free low smoke C-class flame retardant reference )
- Q: Wire and cable fire resistance to meet what standards, which can provide about, thank you!
- Replaced with 30 * 30 PVC flameproof trough, side wiring side cover.
Send your message to us
Corrugated Aluminium Tape armored 144 core Optical fiber communication cable
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1000 m
- Supply Capability:
- 10000 m/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords