Product Classification and Main Technical Specification

 

1), product classification

 

Voltage level: 126kV, 145kV, 170kV, 252kV, 363kV, 420kV, 550kV.

 

Current level: 2000A, 3150A, 4000A, 5000A

 

Auxiliary earthing switch type: None earthing switch, left earthing switch, right earthing switch, double earthing switch.

 

2), Main Technical Specifications

Technical Specifications
GW7-126GW7-145GW7-170
Rated voltage kV
126145170
The rated current A
2000, 3150, 40002000, 3150, 4000, 5000
DisconnectorRated peak withstand current kA125125,160
Rated short-time withstand current (RMS)kA505050,63
Rated short circuit duration s333
Grounding switchRated peak withstand current kA125125125,160
Rated short-time withstand current (RMS)kA505050,63
Rated short circuit duration s333
Rated short-time power frequency withstand voltage (RMS) kVto earth230275325
across isolating point230+70315375
Rated lightning impulse withstand voltage (peak) kVto earth550650750
across isolating point550+100750860
open and close busbar for current transferopen and close current A250025002500
transfer voltage V400400400
open and close times100100100
open and close low currentcapacitance current A112
inductance current A 0.50.51
Radio interference level
less than 500 μv
Mechanical life 
300030003000
rated terminal static mechanic load Nlongitudinal level125015001500
Horizontal level75010001000
Vertical force10012501250
rated contact area mmLongitudinal displacement350350350
horizontal displacement350350350
Vertical displacement300300300
All applied in an altitude of 2000m 

 

Technical Specifications
GW7-252GW7-363GW7-420GW7-550
Rated voltage kV
252363420550
The rated current A
2000, 3150, 4000, 50002000, 3150, 4000, 50003150, 4000,5000
DisconnectorRated peak withstand current kA125, 160125, 160125, 160125, 160
Rated short-time withstand current (RMS)kA50, 6350, 6350, 6350, 63
Rated short circuit duration s3333
Grounding switchRated peak withstand current kA125, 160125, 160125, 160125, 160
Rated short-time withstand current (RMS)kA50, 6350, 6350, 6350, 63
Rated short circuit duration s3333
Rated short-time power frequency withstand voltage (RMS) kVto earth460510520740
across isolating point460+145510+210610740+315
Rated lightning impulse withstand voltage (peak) kVto earth1050117514251675
across isolating point1050+2001175+2951425+2401675+450
Rated operation impulse withstand voltage(peak) kVto earthnone95010501300
across isolating pointnone850+295900+3451175+450
open and close busbar for current transferopen and close current A2500
transfer voltage V427
open and close times100
open and close low currentcapacitance current A2
inductance current A 1
Radio interference level
less than 500 μv
Mechanical life 
3000
rated terminal static mechanic load Nlongitudinal level2000250040004000
Horizontal level1500200020002000
Vertical force1250150020002000
rated contact area mmLongitudinal displacement500500600600
horizontal displacement500500600600
Vertical displacement450450500500
All applied in an altitude of 2000m

 


Q:Rural high voltage transmission line equipment ownership
the transformer can be what, look at the role of electrical appliances can be
Q:Transmission and transformation equipment
Transmission and transformation of basic electrical equipment, including the main wire, transformers, switchgear, high voltage insulators, etc.
Q:Power distribution equipment should be prepared before the blackout?
Before the power failure, the person in charge or the electrical appliance technician should fill in the work order.
Q:Distribution system equipment classification
Special equipment used in a certain industry, such as artillery, automatic teller machine, steel making furnace, etc.
Q:What is the difference between power supply and distribution
The two is the integration of power generation and power supply.
Q:What are the two power distribution equipment?
The two equipment is the equipment for the control, protection, monitoring and measurement of the work of the primary equipment.
Q:DC transmission equipment
Power supply operation of power plant and substation in nowadays are used in DC power supply, it provides power for the control of the load and power load and DC emergency lighting load, is the foundation of modern electric power system control and protection
Q:Difference between distribution voltage and supply voltage
Supply voltage refers to the supply point of the line voltage or phase voltage.
Q:What are the distribution network equipment
suburbs, towns and rural areas, further allocation and supply industry, agriculture, commerce, industry and residents with special needs for electricity secto
Q:AC distribution equipment including distribution box
AC power distribution cabinet is used to distribute electricity, that is from the power transformer has three phase wires of a zero line of a ground load according to the following requirements to the distribution of electric energy

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Related keywords