rated power:31500-180000kVA
rated voltage:11kv
pssed ISO9001and many certificate
Specifications
rated power:31500-180000kVA
rated voltage:4kV
pssed ISO9001and many certificate
low losses
Product Description
11KV oil immersed on-load regulation power transformer has a seires of big changes in material, technical and construction with the characters of small size, light weight, high efficiency with low loss and low noise, stable opable operation which cutting down large number of loss from energy GRID and minising operation charge, improving the industrial economic benefit. It is used in power plant, transformer substation, big-sized and chemistry factory and etc. The product is according to National and IEC standards. Installation: Outdoor Ambient temperature: -30C-+40C Altitude: 1000m Relative Humidity: 90% (25C)
Rated capacity (KVA) | Voltage combination and tap range (KV) | Vector group | S9 series | S10 series | No-load Current (%) | Short-circuit Impedance (%) | |||
HV | LV | No-load loss | Load loss | No-load loss | Load loss | ||||
6300 | 110+/-2*2.5% 121+/-2*2.5% | 6.3 6.6 10.5 11 | Ynd11 | 9.3 | 36 | 8.4 | 34 | 0.77 | 10.5 |
8000 | 11.2 | 45 | 10.1 | 43 | 0.77 | ||||
10000 | 13.2 | 53 | 11.9 | 50 | 0.72 | ||||
12500 | 15.6 | 63 | 14.0 | 60 | 0.72 | ||||
16000 | 18.8 | 77 | 17.0 | 73 | 0.67 | ||||
20000 | 22.0 | 93 | 19.8 | 88 | 0.67 | ||||
25000 | 26.0 | 110 | 23.4 | 105 | 0.62 | ||||
31500 | 30.8 | 133 | 27.7 | 126 | 0.60 | ||||
40000 | 36.8 | 156 | 33.1 | 148 | 0.56 | ||||
50000 | 44.0 | 194 | 39.6 | 184 | 0.52 | ||||
63000 | 52.0 | 234 | 46.8 | 222 | 0.48 | ||||
75000 | 13.8 15.75 18 20 | 59.0 | 278 | 53.1 | 264 | 0.42 | 12-14 | ||
90000 | 68.0 | 320 | 61.2 | 304 | 0.38 | ||||
120000 | 84.8 | 397 | 76.3 | 377 | 0.34 | ||||
150000 | 100.2 | 472 | 90.2 | 448 | 0.30 | ||||
180000 | 112.5 | 532 | 101.3 | 505 | 0.25 |
- Q:Transmission system and distribution system
- Simply put, you can distinguish between the end of the cable to the use of electrical equipment (motor, power box) is the distribution system to the substation, transformer is the transmission system
- Q:Transmission and transformation equipment
- Power transmission and transformation of the protection of the main transformer, relay protection devices, lightning arrester, etc..
- Q:What is the transmission line, what is the power distribution equipment
- As the name implies, the transmission is by the power plant or power center regional power grid (sending end), to the load center power grid (by the end) of the transmission of electricity; power distribution is to be distributed by the substation or bus power down.
- Q:What are the general requirements for working on distribution equipment?
- Can be plugged into the elbow cable connector, not load operation.
- Q:Are electric wires and cables belong to distribution equipment?
- Wire rod products for the transmission of electric (magnetic) energy, information and electromagnetic energy conversion.
- Q:Power distribution equipment should be prepared before the blackout?
- after the high and low voltage power failure, the work must be carried out before the first inspection
- Q:What is the difference between power supply and distribution
- The problem is you estimate from the injection test out the electric power, is the power system of power plant and the national grid is responsible for part of the design, the design of power plant and power lines, its design must be designed by a qualified electric power design institute
- Q:What are the two power distribution equipment?
- The two equipment is the equipment for the control, protection, monitoring and measurement of the work of the primary equipment.
- Q:DC transmission equipment
- Power supply operation of power plant and substation in nowadays are used in DC power supply, it provides power for the control of the load and power load and DC emergency lighting load, is the foundation of modern electric power system control and protection
- Q:Main equipment of high voltage direct current transmission
- Converter also known as converter valve is the key equipment in the converter station, its function is to achieve rectification and inverter
1. Manufacturer Overview |
|
---|---|
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
Dry Transformer 31500-180000kVA
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- -
OKorder Service Pledge
OKorder Financial Service
Similar products
New products
Hot products
Related keywords