• 145KV, 40KA, 2000A three pole single throw Line disconnect switch System 1
145KV, 40KA, 2000A three pole single throw Line disconnect switch

145KV, 40KA, 2000A three pole single throw Line disconnect switch

Ref Price:
get latest price
Loading Port:
Qingdao
Payment Terms:
TT OR LC
Min Order Qty:
1 unit
Supply Capability:
400 unit/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Specifications

1. Outdoor 145kV AC Bus and Line Disconnectors(ISOLATOR) 
2. KEMA test report 
3. ISO quality certificate 
4. Good quality

General introduction :

GW4-40.5/72.5/126/145/170/252 Ⅲ Series, two columns, horizontally rotating type, HV, AC, disconnector

 Product classifications and Main Technical Specifications :

1), Product classification 

Voltage level: 40.5kV, 72.5kV, 126kV, 145kV, 170kV, 252kV. 

Current level: 630A,1250A, 2000A, 2500A,3150A, 4000A. 

Auxiliary earthing switch type: none earthing switch, left earthing switch, right earthing switch, double earthing switches. 

2), Main Technical Specifications

 

Technical Specifications

Product Type

GW4-40.5Ⅲ

GW4-72.5Ⅲ

GW4-126Ⅲ

Rated voltage kV


40.5

72.5

126

The rated current A


1250, 2000, 3150, 4000

Disconnector

Rated peak withstand current kA

100, 125

Rated short-time withstand current (RMS)kA

40, 50

Rated short circuit duration s

4, 3

Grounding switch

Rated peak withstand current kA

100, 125

Rated short-time withstand current (RMS)kA

40, 50

Rated short circuit duration s

4, 3

Rated short-time power frequency withstand voltage (RMS) kV

to earth

95

160

230

across open contacts

118

200

230+70

Rated lightning impulse withstand voltage (peak) kV

to earth

185

350

550

across open contacts

215

410

550+100

minimum clearance in 1 min power frequency withstand voltage when ground blade closing to live part of disconnector


53

94

164

rated terminal static mechanic load N

longitudinal level

1000

1000

1000, 1250

Horizontal level

750

750

750

Vertical force

1000

1000

1000

switching micro-capacitance current A


2

2

2

switching micro-inductance current A


1

1

1

switching busbar for current transfer A (busbar transfer voltage 100V)


400V, 2500A, 100 times

Radio interference level


less than 500 μV

Mechanical life


3000

3000

3000

single pole weight (kg)


120

200

260

Note: All applied to an altitude of 2000m

 

 

Technical Specifications


GW4-145Ⅲ

GW4-170Ⅲ

GW4-252Ⅲ

Rated voltage kV


145

170

252

The rated current A


1250, 2000, 3150, 4000

Disconnector

Rated peak withstand current kA

100, 125

Rated short-time withstand current (RMS)kA

40, 50

Rated short circuit duration s

4, 3

Grounding switch

Rated peak withstand current kA

100, 125

Rated short-time withstand current (RMS)kA

40, 50

Rated short circuit duration s

4, 3

Rated short-time power frequency withstand voltage (RMS) kV

to earth

275

325

460

across open contacts

315

375

460+145

Rated lightning impulse withstand voltage (peak) kV

to earth

650

750

1050

across open contacts

750

860

1050+200

minimum clearance in 1 min power frequency withstand voltage when ground blade closing to live part of disconnector


188

221

291

rated terminal static mechanic load N

longitudinal level

1000, 1250

1500

1500

Horizontal level

750

1000

1000

Vertical force

1250

1250

1250

switching micro-capacitance current A


2

2

2

switching micro-inductance current A


1

1

1

switching busbar for current transfer A (busbar transfer voltage 100V)


400V, 2500A, 100 times

Radio interference level


less than 500 μV

Mechanical life (times)


3000

3000

3000

single pole weight (kg)


300

326

900

Note: All applied to an altitude of 2000m

 


Q: What are the distribution network equipment
suburbs, towns and rural areas, further allocation and supply industry, agriculture, commerce, industry and residents with special needs for electricity secto
Q: What are the general requirements for working on distribution equipment?
Distribution equipment including high voltage power distribution room, substation, power distribution transformer platform, low voltage power distribution room (box), ring network cabinet, cable branch box] outage maintenance,
Q: DC transmission equipment
Simply put, DC screen is to provide stable DC power supply equipment.
Q: What is the power equipment in the distribution room?
The indoor power distribution room with low voltage load is called the power distribution room,
Q: Transmission system and distribution system
Simply put, you can distinguish between the end of the cable to the use of electrical equipment (motor, power box) is the distribution system to the substation, transformer is the transmission system
Q: What is the role of transmission system and distribution system in power grid
The power load center is more concentrated in the industrial zone and the big city,
Q: Transmission lines are not electrical equipment?
If you are satisfied, please accept it as a satisfactory answer
Q: Main equipment of high voltage direct current transmission
It is composed of two or more converter bridges, which can realize the AC DC AC converter.
Q: What is the transmission line, what is the power distribution equipment
Transmission lines generally refers to 110kV and above power lines.
Q: Rural high voltage transmission line equipment ownership
You do not want to what the transformer behind the high-voltage line,

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords