Product Classification and Main Technical Specification
1), product classification
Voltage level: 40.5kV, 72.5kV, 126kV.
Current level: 1250A, 2000A, 3150A.
Auxiliary earthing switch type: none earthing switch, left earthing switch, right earthing switch, double earthing switches.
Rotation type: rotation with an angle of 90 degree, rotation with an angle of 180 degree.
2), Main Technical Specifications
Technical Specifications | Product Type | GW5-40.5Ⅲ | GW5-72.5Ⅲ | GW5-126Ⅲ |
Rated voltage kV | 40.5 | 72.5 | 126 | |
The rated current A | 1250, 2000, 3150 | |||
Disconnector | Rated peak withstand current kA | 100, 125 | ||
Rated short-time withstand current (RMS)kA | 40, 50 | |||
Rated short circuit duration s | 4, 3 | |||
Grounding switch | Rated peak withstand current kA | 100, 125 | ||
Rated short-time withstand current (RMS)kA | 40, 50 | |||
Rated short circuit duration s | 4, 3 | |||
Rated short-time power frequency withstand voltage (RMS) kV | to earth | 95 | 160 | 230 |
across open contacts | 118 | 200 | 230+70 | |
Rated lightning impulse withstand voltage (peak) kV | to earth | 185 | 350 | 550 |
across open contacts | 215 | 410 | 550+100 | |
minimum clearance in 1 min power frequency withstand voltage when ground blade closing to live part of disconnector | 53 | 94 | 164 | |
rated terminal static mechanic load N | longitudinal level | 800, 1000 | 800, 1000 | 1000, 1250 |
Horizontal level | 500, 750 | 500, 750 | 750 | |
Vertical force | 750 | 750 | 1000 | |
switching micro-capacitance current A | 2 | 2 | 2 | |
switching micro-inductance current A | 1 | 1 | 1 | |
switching busbar for current transfer A (busbar transfer voltage 100V) | 400V, 2500A, 100 times | |||
Radio interference level | less than 500 μV | |||
Mechanical life | 3000 | 3000 | 3000 | |
single pole weight (kg) | 120 | 200 | 260 | |
Note: All applied to an altitude of 2000m |
- Q: What are the distribution network equipment
- Electricity and other energy sources, its main features are: cannot be stored in large scale, power generation, transmission, distribution and consumption at the same instant
- Q: AC distribution equipment including distribution box
- Connect the power supply, transformer, converter and other equipment for load distribution box, and monitoring
- Q: What is the power equipment in the distribution room?
- 10kV and below voltage rating equipment, divided into high voltage distribution room and low-voltage distribution room
- Q: What is the role of transmission system and distribution system in power grid
- The distribution of power resources and power load centers in most countries in the world is inconsistent.
- Q: Transmission lines are not electrical equipment?
- Transmission lines are not electrical equipment? The answer is: the device is a function of the assembly
- Q: An introduction to the interpretation of flexible AC transmission systems
- The series compensation device such as thyristor controlled series capacitor (TCSC), thyristor controlled reactor (TCSR), static synchronous series compensator (SSSC), active power flow is mainly used to change the system of distribution, improve the system transmission capacity and transient stability etc.;
- Q: Main equipment of high voltage direct current transmission
- Converter also known as converter valve is the key equipment in the converter station, its function is to achieve rectification and inverter
- Q: What is the transmission line, what is the power distribution equipment
- Distribution equipment is generally referred to as the distribution lines and distribution substations (usually 35kV and below).
- Q: Power distribution equipment should be prepared before the blackout?
- Before the power failure, the person in charge or the electrical appliance technician should fill in the work order.
- Q: CHINT group in the transmission and distribution equipment to do it?
- The national grid is not purchasing some equipment of CHINT, CHINT group is now very powerful
Send your message to us
66kV V Type Switch Disconnector with electric operating mechanism
- Loading Port:
- Qingdao
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 unit
- Supply Capability:
- 400 unit/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches