• 66kV V Type Switch Disconnector with electric operating mechanism System 1
66kV V Type Switch Disconnector with electric operating mechanism

66kV V Type Switch Disconnector with electric operating mechanism

Ref Price:
get latest price
Loading Port:
Qingdao
Payment Terms:
TT OR LC
Min Order Qty:
1 unit
Supply Capability:
400 unit/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Product Classification and Main Technical Specification

 

1), product classification

 

Voltage level: 40.5kV, 72.5kV, 126kV.

 

Current level: 1250A, 2000A, 3150A.

 

Auxiliary earthing switch type: none earthing switch, left earthing switch, right earthing switch, double earthing switches.

 

Rotation type: rotation with an angle of 90 degree, rotation with an angle of 180 degree.

 

2), Main Technical Specifications

 

Technical Specifications

Product Type

GW5-40.5

GW5-72.5

GW5-126

Rated voltage kV


40.5

72.5

126

The rated current A


1250, 2000, 3150

Disconnector

Rated peak withstand current kA

100, 125

Rated short-time withstand current (RMS)kA

40, 50

Rated short circuit duration s

4, 3

Grounding switch

Rated peak withstand current kA

100, 125

Rated short-time withstand current (RMS)kA

40, 50

Rated short circuit duration s

4, 3

Rated short-time power frequency withstand voltage (RMS) kV

to earth

95

160

230

across open contacts

118

200

230+70

Rated lightning impulse withstand voltage (peak) kV

to earth

185

350

550

across open contacts

215

410

550+100

minimum clearance in 1 min power frequency withstand voltage when ground blade closing to live part of disconnector


53

94

164

rated terminal static mechanic load N

longitudinal level

800, 1000

800, 1000

1000, 1250

Horizontal level

500, 750

500, 750

750

Vertical force

750

750

1000

switching micro-capacitance current A


2

2

2

switching micro-inductance current A


1

1

1

switching busbar for current transfer A (busbar transfer voltage 100V)


400V, 2500A, 100 times

Radio interference level


less than 500 μV

Mechanical life


3000

3000

3000

single pole weight (kg)


120

200

260

Note: All applied to an altitude of 2000m


Q:What is the transmission line, what is the power distribution equipment
Usually an overhead line, a very small number of lines (or some of them) is a cable line
Q:What are the general requirements for working on distribution equipment?
Distribution equipment including high voltage power distribution room, substation, power distribution transformer platform, low voltage power distribution room (box), ring network cabinet, cable branch box] outage maintenance,
Q:Power distribution equipment should be prepared before the blackout?
electrician received power outage notice, pull down the knife switch, accept fuse.
Q:What is the power equipment in the distribution room?
which is mainly used for the distribution of the electric energy of the low-voltage users, and the utility model is provided with a medium voltage input line (a small number of outlets)
Q:What is the role of transmission system and distribution system in power grid
The power load center is more concentrated in the industrial zone and the big city,
Q:What is the difference between power supply and distribution
The problem is you estimate from the injection test out the electric power, is the power system of power plant and the national grid is responsible for part of the design, the design of power plant and power lines, its design must be designed by a qualified electric power design institute
Q:An introduction to the interpretation of flexible AC transmission systems
The series compensation device such as thyristor controlled series capacitor (TCSC), thyristor controlled reactor (TCSR), static synchronous series compensator (SSSC), active power flow is mainly used to change the system of distribution, improve the system transmission capacity and transient stability etc.;
Q:Transmission lines are not electrical equipment?
Transmission lines are not electrical equipment? The answer is: the device is a function of the assembly
Q:Main equipment of high voltage direct current transmission
The utility model comprises a converter, a converter transformer, a smoothing reactor, an AC filter, a DC lightning arrester and a control protection device.
Q:Difference between distribution voltage and supply voltage
A distribution within the cell, the high voltage side is 10KV, the low voltage side is 220V or 380V.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products