Cable end sealing cap

Ref Price:
Loading Port:
China Main Port
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
-

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Application:

It is used to seal the ends of all types of cables and protect from ingress of water and moisture,there are heat shrink cable end sealing caps and elastic cable end sealing caps.

1,Heat shrink cable end sealing caps

Features and applications:

Heat shrink cable end sealing caps are made from high quality cross-link polyolefin material,and the hot melt adhesive lining provides seal on irregular cable sheaths.With excellent resistance to weathering,moisture,contamination and adverse environmental conditions,it is the ideal sealing material for cable ends.Apply to seal communication cable,power cable,optical fiber cable and other types of cables,sealing well and good tightness,heat shrink cable end sealing caps provide for efficient and positive cable end sealing.

Technical specifications:


拉伸强度
tensile strength
>16.7Mpa
断裂伸长率
elongation at break
>300%
收缩率
Shrinkage
≥45%
偏芯度
Eccentricity
≤30%
收缩温度
Shrinkage Temperature
150-160℃
 

Regular sizes:


产品编号
Item No
规格:内径*长度
Size:ID*L(mm)
适用外径
Applicable Diameter(mm)
产品编号
Item No
规格:内径*长度
Size:ID*L(mm)
适用外径
Applicable Diameter(mm)
产品编号
Item No
规格:内径*长度
Size:ID*L(mm)
适用外径
Applicable Diameter(mm)
110*406-81540*5533-382975*9068-72
213*409-111640*7033-383075*12068-72
315*409-131745*5539-423180*9073-77
415*509-131845*7039-423280*12073-77
518*4014-161950*7043-473385*12078-82
618*5014-162050*9043-473490*12083-87
720*4014-182155*7048-523590*15083-87
820*6014-182255*9048-5236100*12088-97
925*4019-232360*7053-5737100*15088-97
1025*6019-232460*9053-5738110*15098-107
1130*5524-282565*7058-6239120*150108-117
1230*6024-282665*9058-6240130*150118-127
1335*5529-322770*9063-6741150*200128-147
1435*6029-322870*12063-67


Note:

1,using electron irradiation process to prevent aging

2,valves end caps are available

3,company name,logo and etc.can be printed on the end caps according to customer's requirements.

2,Elastic(PVC)cable end sealing caps

Features and applications:

Elastic(PVC)cable end sealing caps are made from specially formulated Polyvinyl Chloride(PVC)material,and it is push-on type application.Compared to heat shrink cable end sealing caps,it is quick and easy installation,no tools&skills are required,extremely economical and cost effective.The caps will not crack or split,perfect protection to cable ends from weathering,moicture and contamination.

Technical specifications:


拉伸强度
tensile strength
>12Mpa
断裂伸长率
elongation at break
>350%
介电强度
Dielectric strength
12KV/mm
 

Regular sizes:


产品编号
Item No
规格:内径*长度
Size:ID*L(mm)
壁     厚
Thickness(mm)
适用外径
Applicable Diameter(mm)
产品编号
Item No
规格:内径*长度
Size:ID*L(mm)
壁     厚
Thickness(mm)
适用外径
Applicable Diameter(mm)
12.0*150.82.1-2.71212*351.512.2-14
22.5*150.82.7-3.71314*351.514-16
33.0*150.83.1-4.11416*351.516-18
43.5*150.83.7-4.71518*40218-20
54*150.84.2-5.21620*40220-22
65*200.85.2-6.21725*45222-24
76*200.86.2-7.21824*45224-26
87*2017.2-8.21926*50226-29
98*2518.2-9.22028*55228-31
109*251.29.2-10.22130*602.230-35
1110*301.210.2-12



Note:company name,logo and etc,can be printed on the end caps according to customer's requirements.


Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Buy Taipower c 450P with remote control to add audio and video cable
Set-top box with the AV cable connection: yellow - video, red and white - audio, corresponding to the TV's AV input interface can be connected (do not receive the TV component interface). As for the emergence of partial pink, the possible reasons are: . poor contact. You will re-connect the three-color AV cable to the set-top box, on the TV, to ensure good contact. . cable quality. Three-color AV cable may not be the quality, if you can replace a group of try, or use the DVD and other equipment connected with the TV to test the AV line with or without problems. . TV AV input failure. You can use other video source equipment connected to the TV test, such as: DVD, VCD machines and so on. . set-top box failure. May be set-top box AV output port problems, if there are multiple sets of AV output, you can try other port okay, not the case may be the quality of set-top box, call customer service it.
Q:What is the difference between a trunking and a bridge in a weak construction?
Power circuit box, the home of the circuit is divided into lighting, walls, air conditioning, etc., there is the bathroom and the kitchen line and the separation of the room.
Q:What is the current good computer configuration on the market? The price of 4000 yuan or so no more than 4000 assembly parts to write down the price Thank you.
No way to save money! Moreover, the signal to you there, almost all attenuation finished.
Q:What kind of KVM switch is this configuration below?
Wire and cable warranty period is 30 years of national warranty period. But the specific warranty period according to the type of wire and cable and the use of conditions and temperature and applicable methods to determine. General cable maintenance period is about 15 years, but to ensure that the normal use of the environment, such as the amount of temperature is below 70 degrees, but you are more than 70 working environment to use, of course, may not be used for a year. Therefore, the most important thing is to follow the instructions to use.
Q:Home wiring is a good line or a good line? Talk about the difference
This approach is a lot of the general is to extend the city line, that is, line 220V AC line lengthened, some in Taobao. 2. to extend the low-voltage line, engage in a power plug on the plug, the same set of seats, you can easily do an extension line, when you want to use, docking about it, when you can not close up. This is also on Taobao, when to buy, pay attention to the socket, plug the model to the on.
Q:Automotive wiring harness welding to pay attention to what the problem
5 small cable, if you feel high cost Can be from the distribution box to the circuit The first light using a small cable low-voltage bus to the equipment side, due to the power distribution room to the equipment side will appear more climbing, bus installation climbing very troublesome and affect the beautiful, The bus outlet cabinet uses cables and installs the transfer box on the busbar
Q:Wire and cable CCC product consistency is what
What brand of wire pipe PVC pipe used? Is not in the financial or plastic surgery better ah? Guiqiu we recommend, thank you! What brand of network cable used a good, need double shielded cable, thank you
Q:Seeking the basement of the outer wall piercing the cable after the casing, how to solve the water (200 points online)
If you use the color component output, you have to have the color difference component interface. With the color line facing the same color on the line. AV line of the yellow plug is the video, red and white is the audio delay Han silhouette cellar jealous of the tea, according to the same color received TV
Q:What is the cable for rvv? Is it a power cable or a control cable? What is the cable?
The installation process is a certain requirement, high and low voltage cable bridge should be installed separately as usual, a wall laying vertical pipeline (slot) or installation equipment, the power distribution between the depth of D1 = 1200 ~ 1500mm; weak Between the deep distance from the D2 = 1100 ~ 1400mm more reasonable. The length L1 and L2 between the power distribution and the weak can be determined according to how much electrical equipment and pipelines (slots) are installed in the room. "Civil building electrical design specifications" proposed "shaft size in addition to meet the wiring spacing and terminal box, distribution box layout must be the size, but also in the box before the left not less than 0.8m operation, maintenance distance" requirements. In the weak equipment, the operation and maintenance distance is not specified in the provisions of the Code for Electrical Design of Civil Buildings, but it should not be less than 0.8m. Cable to wear steel pipe wiring, should be reserved in the floor steel pipe, wiring should be completed after the plug fire fire blocking material. Cable bridge installation should be horizontal, the maximum sag should not be greater than 10 mm; proposed separate installation
Q:What does the letter of the computer cable model mean?
(The difference between the two cables: WDZ and WDZC are the combustion characteristics of the cable, both halogen-free low smoke flame retardant cable, but the former is a single vertical flame retardant test, which is bundled combustion C class flame retardant Test, but the flame retardant performance requirements are not the same. The meaning of the letter: W refers to the halogen-free; D refers to the low smoke; Z refers to the flame retardant WDZ is halogen-free low smoke flame retardant jacket power cable. WDZC refers to halogen-free low smoke C-class flame retardant reference )

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range