Product Description:

Range summary

The EosG range of gel technology batteries offers outstanding performance including  a 15+ years design life .

The EosG series batteries is designed based on the Eos series.

Using the polymer gel electrolyte .

Built to the highest standards and compliant with the latest IEC60896-21/22 standard .

This range also offers 100% capacity out-of-the-box and is capable of handling deep discharges for complete peace of mind. The use of flexible  connectors and the ability to be installed  both horizontally and vertically allows for multiple installation possibilities.

Technical features

  • Above 15 years designed life

  • Reliable post sealing structure

  • Excellent charging acceptant ability

  • Excellent performance at extreme high  and low temperature

  • Low self-discharge ability

  • Flexible and convenient installation  with slinky outside looking

 

Type:

  EosG300

Voltage:

  2V

Nominal Capacity:

  300Ah(C10)  300Ah(10 hours rate:)

Length:

  123mm

Width:

  184.5mm

Height:

  360.5mm

Height   with termial:

  372mm

Weight:

  19Kg

Compliant standards

    • IEC60896-21/22

    • BS6290 part 4

    • Telcordia SR4228

    • Eurobat guide

    • UL

    • Manufactured under system ISO9001(TUV)                                          

    Battery installation compliant with:

    • EN 50272-2 or local equivalents

    Main applications

    • Correspondence exchange and transmission system

    • Mobile communication system

    • Power plant and power transformer system

    • Navigation and signaling system

    • Solar energy system

    • Radio and broadcasting station

    • Emergency lighting system

    Products characteristics:

    • Plate special patent calcium and tin  lead alloy and thick plate design

    • Container ABS(V0 optional)

    • Separator AGM

    • Valve EPDR

    • Electrolyte using the polymer gel electrolyte

    • Terminal M8 copper core posts

    FAQ

    What is sulfation of batteries?

    Sulfation is the formation or deposit of lead sulfate on the surface and in the pores of the active material of the batteries' lead plates. If the sulfation becomes excessive and forms large crystals on the plates, the battery will not operate efficiently and may not work at all. Common causes of battery sulfation are standing a long time in a discharged condition, operating at excessive temperatures, and prolonged under or over charging.

    How long a battery can last?

    The service design life of a battery are vary considerably with how it is used, how it is maintained and charged, temperature, and other factors.

    Do batteries self-discharge when not in use?

    All batteries, regardless of their chemistry, self-discharge. The rate of self-discharge depends both on the type of battery and the storage temperature the batteries are exposed to. However, for a good estimate, Narada batteries self-discharge approximately 4% per week at 80ĄăF.

     

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:How should the battery be well maintained?
Voltage check the state of the battery standard voltage should be maintained between 12.2 ~ 12.7V. If the voltage is too low should be charged, the charge should be kept small charge for a long time. Battery charging need to use a professional charger, the owner will not try to charge their own, the owner can only keep the engine running on the battery can be charged. If the battery aging should be replaced.
Q:How to deal with waste batteries?
Laboratory recycling method: ordinary dry battery is cylindrical, the outer cylinder made of zinc, the zinc cylinder is the battery negative; tube central carbon rod for the positive; tube for the manganese dioxide, ammonium chloride and chlorination Zinc.
Q:What is the difference between a maintenance-free battery and a conventional battery?
Lead-acid battery is composed of positive and negative plates, partitions, shell, electrolyte and wiring pile head and other components, the discharge of the chemical reaction is to rely on positive electrode active substances (lead dioxide and lead) and negative plate active substances (sponge Pure lead) in the electrolyte (dilute sulfuric acid solution) under the action, which plate grid, the traditional battery lead and antimony alloy manufacturing, maintenance-free battery is made of lead calcium alloy, the former with antimony, the latter with calcium, This is the fundamental difference between the two points.
Q:How to repair the battery?
To the battery in accordance with the 0.1C current discharge, record the discharge time. Its discharge current multiplied by the number of hours of time, is the battery repair capacity. If the Chongqing battery capacity to reach the nominal capacity of more than 70%, the end of the repair.
Q:What battery does the van use?
The most obvious feature of lead-acid batteries is the top of the plastic cover can be unscrewed, there are ventilation holes above. These fillers are used to fill pure water, check the electrolyte and the use of exhaust gas. In theory, lead-acid batteries need to check the density of each electrolyte and the level of liquid, if there is a need to add distilled water. But with the upgrading of battery manufacturing technology, lead-acid battery development for the lead-acid maintenance-free batteries and colloidal maintenance-free batteries, lead-acid batteries do not need to add electrolyte or distilled water. Mainly the use of positive electrode to produce oxygen can be absorbed in the negative oxygen cycle, to prevent water reduction. Lead-acid water batteries are mostly used in tractors, tricycles, car start, etc., and maintenance-free lead-acid battery wider range of applications, including uninterruptible power supply, electric vehicle power, electric bicycle batteries. Lead-acid batteries according to the application needs to be divided into constant current discharge (such as uninterruptible power supply) and instantaneous discharge (such as car to start the battery).
Q:How to determine the battery is good or bad?
If less than 9V but the pointer is in a certain value does not move that the battery is in a state of loss, need to add charge.
Q:What is a maintenanceable battery?
It also has a shock, high temperature, small size, self-discharge characteristics. Life is generally twice the ordinary battery.
Q:Lead-acid battery how to maintain?
When receiving the battery should first check whether the phenomenon of short circuit, first short circuit repair and then fill the distilled water.
Q:Maintenance-free battery how to detect it?
Keep the battery surface clean. If the discovery of solid oxide on the pole, it should be timely with hot water pouring, to be removed, so as not to affect the pole and the terminal between the continuity. After cleaning up, wipe the battery surface, in the pole and the terminal cast on the butter to ensure that the pole is not oxidized.
Q:What kind of battery is divided into?
At present, we used the car battery is divided into three categories, namely, ordinary batteries, dry batteries and maintenance-free batteries three.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range