1KVA Rack / Tower Puresine Wave Online Extensible G-sensor LCD UPS 1

Ref Price:
Loading Port:
Payment Terms:
Min Order Qty:
30 unit
Supply Capability:
300000 unit/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:


Rated power1KVA2KVA3KVA
DisplayLED or LCD, depends on user's choice
Frequency110V:46~54Hz or 56~64Hz/220V:40~60Hz/Adjustable by software
Frequency110V:46~64Hz/220V:46~54Hz/Same as AC(AC mode)
110V: 50 or 60±0.2Hz/220V:50±0.2Hz(Batt. mode)
Wave formSine wave
QTY. & capacity of battery12V/7.5AH*3pcs—————2V/7.5AH*8pcs—————12V/7.5AH*8pcs—————
Nominal DC input voltage—————36VDC—————96VDC—————96VDC
Transfer time0 ms
Overload capability110%~150% for 30% seconds then transfer to bypass output, 150% above for 300 milliseconds.
Environment of performanceTemperature 0℃~40℃, Humidity 20%~90%
(kg) / Net weight (kg)110V:19   220V:16.3110V:11.8 220V:9.138.1kg(10.3kg for US+27.8kg for battery pack)110V:14.2 220V:11.539kg(11.2kg for US+27.8kg for battery pack)110V:15 220V:12.3
(mm) / Unit dimention (mm)441*445*88441*445*88(*2 sets, there into 1 set for battery pack)441*445*88441*445*88(*2 sets, there into 1 set for battery pack)441*445*88
Interface110V:USB+RS232 220V:RJ45/11+RS232, Intelling slot selectable.



1. Wide range of input voltage

The UPS can offer normal and stable service voltage under its input voltage range. When the input voltage is out of its range the machine will switch to battery mode automatically to keep the output power in order to protect the equipment, such as computers, ensure they will not be damaged by the over high or over low voltage, users can continue the operation of equipment for a while or save the data on computers while the power network is abnormal.


2. Wide range of AVR(Automatic voltage regulation)

In the product’s input voltage range and under 3 steps of intelligent AVR function, it can provide a stable output voltage.


3. Automatic self detection when UPS on(LED).

Before the UPS on, red, yellow, blue LED will light up two times by cycle turns, after self detection UPS switch to AC mode/battery mode or working mode. 


4. Silence function

In the "battery mode", shortly press the switch to turn off the buzzer. But the battery is about to run out or the load is too heavy, the buzzer sound cannot be muted.


5. Overload protection

In the battery mode, output voltage turn down correspondingly when it is overload, after the capacity of load is lower than the rated power then output voltage will back to rated value, it ensures the UPS will not shut down by abrupt overload which caused by surging current during the computer is working and other equipment is added.


6. Short circuit protection

When the mis-operation caused the load short circuit or computer failure (such as power tube breakdown of switch) cause short circuit, the UPS will shutdown automatically for protection.


7. The low current switch

This UPS adopts low current switch to extend the service life which is longer than conventional battery and high current switch in AC current path.


8. Automatic charging

There are two charging mode, charging time is faster than ordinary charging mode, higher efficiency, and greatly prolonging the service life of the battery.


9. With a bypass output

Independent bypass output socket for external printers or scanners of computer peripherals, with surge protection of the load.


1KVA Rack / Tower Puresine Wave Online Extensible G-sensor LCD UPS 1

1KVA Rack / Tower Puresine Wave Online Extensible G-sensor LCD UPS 1

1KVA Rack / Tower Puresine Wave Online Extensible G-sensor LCD UPS 1

1KVA Rack / Tower Puresine Wave Online Extensible G-sensor LCD UPS 1

1KVA Rack / Tower Puresine Wave Online Extensible G-sensor LCD UPS 1


1.    Where can I buy your products?

You could find our products from dealers or contact our sales team directly. We will provide you with detailed services.

2.    How to contact us?

Contact details can be found from website www.okorder.com to contact us. We look forward to providing you with professional services.

3.    What is the application field of your products?

Our current GW1500~4600-SS series and GW3000~4600-DS, with the flexible expansion ability and allocation capability, can be used in the small photovoltaic (PV) grid power generation systems of family units as well as the commercial photovoltaic system such as BIPV, BAPV and etc.

4.    What kinds of modules do your inventers support?

Our inventers support most of mainstream components and modules in the market. Should you require more details, please do not hesitate to contact our technical personnel.

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:What are the methods of photovoltaic grid-connected inverter control
Sine wave output inverter control integrated circuits, sine wave output of the inverter, the control circuit can be used microprocessor control, such as INTEL company produced 80C196MC, Motorola produced MP16 and MI-CROCHIP company PIC16C73 and so on, these single-chip microcomputer has a multi-channel PWM generator,
Q:Grid-connected inverter is generally divided into photovoltaic power generation grid-connected inverter, wind power grid-connected inverter, power equipment and grid-connected inverter and other power generation equipment power generation inverter.
Grid-connected inverter is generally used with large-scale photovoltaic power plant system, a lot of parallel PV string is connected to the same set of inverter DC input, the general power of the use of three-phase IGBT power module, power
Q:What is the difference between low voltage grid connection and medium voltage grid connection?
The difference is that the current at low voltage and the grid is large, the current is small when the voltage is small, followed by the low voltage crossing parameter setting problem (such as PV inverter integrated with inverter and low voltage crossing function, not all photovoltaic inverter
Q:Is the PV inverter a current source or a voltage source?
Photovoltaic inverter, also known as power regulator, according to the inverter in the use of photovoltaic power generation system can be divided into two kinds of independent power supply and grid.
Q:How the output voltage of the PV inverter and the grid-connected voltage are determined
supply through the cable to the battery. The use of household appliances connected to the power converter output can be used in the car a variety of electrical appliances. The available electrical appliances are: mobile phones, laptops, digital cameras, cameras, lights, electric razors, CD players, game consoles, handheld computers, power tools, car refrigerators and various tourism, camping, medical emergency appliances Wait.
Q:PV grid-connected inverter and independent inverter in the control of what is the difference
The independent inverter in the output voltage phase amplitude of the frequency control is initially set good. Independent inverter, you should refer to off-grid inverter, do not need to consider the grid situation.
Q:What is the difference between a PV grid-connected inverter and an off-grid inverter?
Grid-connected inverter does not need energy storage, but the energy can not be controlled, the number of photovoltaic sent to send online how much, simply do not want people to.
Q:What is the PV inverter starting voltage
sine wave becomes narrower and the voltage width in the center of the sine wave is widened and the switching element is always operated in a direction at a certain frequency in a half cycle, A pulse wave train (pseudo sine wave). Then let the pulse wave form a sine wave through a simple filter
Q:After the PV inverter, how to achieve the same period before the network?
It can automatically detect the generator and the grid frequency and voltage, in the frequency, voltage, phase are in line with the requirements of the grid to set the time before the release of the closing signal, so that it can be safely and securely connected.
Q:Photovoltaic grid-connected inverter problem
Hello, the definition of the zero line is not caused by the transformer three-phase electric tail connection? I now do not understand why there is no isolation transformer AC output marked is N (zero line), and it is not the transformer three-phase power of the tail connection leads to, this is the zero line? The The

1. Manufacturer Overview

Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range