Description Of 0.4KW ~400KW 50Hz/60Hz AC Motor Drive
CMAX frequency inverter is a high-quality, multi-function, low-noise variable frequency drive which is designed, developed and manufactured according to international standards. It can meet different needs of industrial conditions.The inverter applies advanced control technology of space voltage vector PWM, with functions of constant voltage control, power-off restart, dead zone compensation, automatic torque compensation, online modification parameter, high-speed impulse input, simple PLC and traverse
Features Of 0.4KW ~400KW 50Hz/60Hz AC Motor Drive
1).Adopts 16 bit microprocessor, sine wave PWM control2).Automatic torque ascension and automatic sliding compensation function
3).Output frequency 0.1-400 Hz
4).8 period of speed setting and 7 period can be running the program
5).Low noise, carrier frequency can from 1 kHz-15 kHz adjustment
6).Two paragraphs Acceleration and deceleration time and two segments of the S Curve slow and deceleration
7).Simulation frequency set acceptable 0-10 VDC, 4-20 mA
8).The built-in serial communication interface RS-485(baud rate can reach 38400)
9).Save energy running and automatic voltage stabilizing section function (AVR)
10).Adjustable V/F curve Acceleration and automatic and deceleration function
11).Simple vector control and built-in PID control, and the simple positioning function
12).Sleep/wake up function and zero velocity keep function
Structure Of 0.4KW ~400KW 50Hz/60Hz AC Motor Drive

Application Of 0.4KW ~400KW 50Hz/60Hz AC Motor Drive
★Textile: coarse spinner, spinning frame, wrap-knitting machine, loom, knitting machine, silk-spinning machine, etc.★Plastic: extruder, hauling machine, decorating machine, etc.
★Pharmacy: mixer, roaster, etc.
★Woodworking: engraving machine, sander, veneer peeling lathe, etc.
★Papermaking: single type papermaking machine, etc.
★Machine tool: non-core grinding machine, optical lens grinding machine, cutting mill, etc.
★Printing: cloth-washing machine, dye vat, etc.
★Cement: feeder, air blower, rotary furnace, mixer, crusher, etc
★Fan and pump: kinds of fans, blowers and pumps
Performance Of 0.4KW ~400KW 50Hz/60Hz AC Motor Drive
Item | Specification | |||||||
Input | Rated voltage | T4 series: Three phase 380v, ±15% | ||||||
Frequency | S/T2 series: Three/single phase 220V, ±15% | |||||||
50/60Hz ±5% | ||||||||
Output | Voltage | T4 series: Three phase 0-380V | ||||||
Frequency | S/T2 series: Three phase 0~220v | |||||||
0-400Hz | ||||||||
Overload ability | 150% rated current for 30s; 180% rated current for 1s; | |||||||
Dissipation | Cooling type | Forced Cooling | ||||||
Temperature protection | Heatsink temperature >85℃ trip protection against overheat | |||||||
Fan control | Heatsink temperature> 50℃, fan forced operation, frequency inverter continue work | |||||||
Control | Control mode | Open-loop vector control, V/F control | ||||||
Performance | Start torque | Open-loop vector control: 0.5Hz 180%; | ||||||
VF control: 0.5Hz 150% | ||||||||
Speed range | Open-loop vector control:1:150; | |||||||
VF control:1:100 | ||||||||
Speed control precision | Open-loop vector control: ±0.2%; | |||||||
VF control:±0.5% | ||||||||
Function | Channel of operation command | Keyboard control,terminal control,communication control | ||||||
Start mode | Direct start, DC injection braking before start, speed tracking before start | |||||||
DC injection braking | Start DC injection braking, stop DC injection braking | |||||||
Dynamic braking | Built-in braking unit | |||||||
Frequency source choice | Keyboard digital frequency setting, analog AVI setting | |||||||
PID control setting, telecommunications setting | ||||||||
Frequency resolution | Keypad setting:0.01Hz; Analog setting: 0.1% | |||||||
Carrier frequency | 1Khz~12Khz, | |||||||
Acc/Dec time | 0.1~6000.0s or 0.01~600.00s | |||||||
Signal | Analog input | AVI:0~10V | ||||||
ACI:4~20mA | ||||||||
Keyboard potentiometer input: 0~10V | ||||||||
Analog output | AFM:0~10V or 0~20mA, Select through JP1 jumper | |||||||
Digital input | A total of 28 kinds of function could be selected from S0 ~S5. | |||||||
Digital output | 1 channel open collector output(MO1-MCM) | |||||||
1 channel relay output( TA-TC normally open, TB-TC normally closed; | ||||||||
Communication Port | Communication protocol | Based on RS485 hardware, support standard MODBUS protocol. | ||||||
Display Functions | Four digital tube display | Can monitor the operation state of frequency inverter flexibly and conveniently. | ||||||
Installation | Humidity | Less than 90%RH | ||||||
condensation | ||||||||
Vibration | Less than0.6G | |||||||
Elevation | 0~1000m, reduce the rated specification 10% when lift 1000m for each. | |||||||
Storage temperature | -20~60℃ | |||||||
Structure | Defend degree | IP20 |
- Q: Is it possible to use a different laptop's power adapter?
- For the power adapter, whether access to equipment, the following aspects of the measurement standards: Interface form The interface plug and socket used must be dimensioned. Voltage size The output voltage of the adapter is the same as the required voltage of the connected device (eg notebook). Inconsistencies may not be able to start or burn the device properly. Current or power The power of the adapter is greater than the maximum power required by the device. Power is not enough, may cause the voltage to drop, the adapter is hot, or burn the adapter. More than the above, the use of more power of the power adapter, while meeting the interface and voltage conditions, it can be replaced.
- Q: 65w adapter and 90w laptop power adapter What is the difference?
- 65W and 90W is mainly based on your laptop power configuration, the general integrated graphics with 65W, discrete graphics because of the need for additional power supply, so the general need 90W, of course, there are some low-power CPU, such as 25WCPU , 35W, 45W difference, these are the beginning of the manufacturer according to the notebook's power consumption count a maximum power, and then give your laptop with adapter 90W adapter can replace 65W, as long as the interface is the same, but 65W instead of 90W sometimes there may be insufficient power lead to automatic shutdown. In general, the greater the number of watts, the larger the head, because the adapter is actually a coil will be 220V into 19V, according to the power to determine the head, the larger the watt, the same 19V, then the output current will be greater
- Q: What is the working principle of high voltage electrodes and frequency converters?
- High-voltage inverter is the input power supply voltage above 3KV high-power inverter, the main voltage levels are 3000V, 3300V, 6000V, 6600V, 10000V and other voltage levels of high-voltage high-power inverter High voltage inverter from high - low - high; low - high; high - high points.
- Q: What are the differences and links between the soft starters and the frequency converters, and their respective principles and uses?
- The soft starter is activated by adjusting the voltage and current, and the frequency converter starts the motor by changing the frequency of the power supply. The soft starter can theoretically smooth and gradually start the motor to the maximum speed. No impact current (ordinary start-up current is 6-7 times the rated current) The inverter is best suited for tap water and fans, etc. The soft starter is not suitable for everything except for heavy load start.
- Q: Laptop power adapter output voltage is not the same as the current? What's the effect?
- In the case of other conditions (rated output voltage, plug polarity, etc.) the same circumstances, the rated output current greater power adapter, can replace the rated output current is relatively small power adapter, which is not adversely affected. If the power adapter with a relatively small rated current is used instead of a relatively large power adapter with a rated output current, the power adapter will be "overloaded" and may cause damage to the power adapter.
- Q: Yasukawa inverter reported bb code that is the reason why the base blockade?
- This is not a fault! Only after the inverter receives the base block signal, it is not output!
- Q: Who knows how the inverter is calculated?
- There is no pole in the inverter, the electrode can be polarized, the greater the number of poles of the motor the slower the speed, please refer to.
- Q: What is the meaning of the bipolar polarity in the inverter ah There is a +10V signal input is a -10V What is the meaning of ah?
- Bipolar input is positive and negative. Bipolar input is generally used to directly through the external reference or potentiometer to achieve the motor forward and reverse switching, without having to switch all the way to switch the signal (switch).
- Q: 30 kW 6 pole frequency motor torque is how much
- Look at the motor sample or nameplate, above some Different manufacturers of the motor may be different I have a sample on hand, 90KW, six pole, frame number 315M1, rated current 168A, rated torque 859.4 And then look at your inverter performance and motor performance, and can generally be overloaded to the rated torque of 150%
- Q: The emitter E of the inverter inverter module and the AC output U are not directly connected together
- Pairs of modules are connected in a phase branch The phase output is derived from the neutral point between the modules
1. Manufacturer Overview
Location | Liaoning,China |
Year Established | 2001 |
Annual Output Value | US$5 Million - US$10 Million |
Main Markets | North America South America Eastern Europe Southeast Asia Africa Oceania Mid East Eastern Asia Western Europe |
Company Certifications | ISO9001 |
2. Manufacturer Certificates
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability
a) Trade Capacity | |
Nearest Port | DALIAN |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | ENGLISH,CHINESE |
b) Factory Information | |
Factory Size: | 5,000-10,000 square meters |
No. of Production Lines | Above 10 |
Contract Manufacturing | OEM Service Offered Design Service Offered Buyer Label Offered |
Product Price Range | Low and/or Average |
Send your message to us
0.4KW ~400KW 50Hz/60Hz AC Motor Drive
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1 pc pc
- Supply Capability:
- 5000 pcs per month pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords