WQ Series Submersible Centrifugal Sewage Pump

Ref Price:
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 set
Supply Capability:
10000 set/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

PRODUCT INFORMATION

WQ series submersible non-clog sewage pump in the introduction of foreign advanced technology, based on the joint efforts by our researchers, while a wide range of suggestions from pump experts, and after many improvements and successfully developed, tested each Top performance indicators are that the advanced level of similar foreign producing countries. Used in chemical, petroleum, pharmaceutical, mining, paper industry, cement plants, steel mills, power plants, coal processing industry, and urban sewage treatment plant drainage systems, municipal engineering, construction sites etc sewage particles, dirt, can also be used to pump clean water and corrosive media.

Model significance

50WQ (QW) 25-32-5.5

50 caliber 50mm exhaust ----

WQ (QW) --- submersible sewage pump

25 ---- flow of 25m3 / h

32 ---- lift 32m

5.5 --- with motor power 5.5KW

Performance range

Flow: 7-950m3 / h

Head: 7-35m

Features

1. When using a unique monolithic or double blade wheel structure, greatly improving the living creatures capacity, can effectively through five times the diameter of the fiber material and pump caliber pump diameter of about 50% of the solid particles.

2. Mechanical seal with anticorrosive hard softening tungsten materials, can pump more than 8000 hours of continuous operation safety.

3. The overall structure is compact, small size, low noise, energy-saving effect is remarkable, easy maintenance, no need to build pumping stations, poured into the water to work, greatly reducing the project cost.

4. The pump seal oil chamber with high precision interference leakage detection sensors embedded in the stator windings of the thermal components, automatic protection of pump motor.

5. According to user needs with automatic control cabinet, the pump leakage, leakage, overload and overtemperature protection automatically improve product safety and reliability.

6. float switch can change depending on the desired level, the automatic control of pump start and stop, without special care, extremely easy to use.

7.WQ series according to user needs with double rail automatic coupling installation system, install it to bring more convenient maintenance, may not have to get into the sump.

8. be able to use in the whole head, but to ensure that the motor is not overloaded.

9. There are two types of installation, fixed automatic coupling installation system and traveling free installation system.


FAQ

We have organized several common questions for our clients,may help you sincerely: 

①How about your company?

A world class manufacturer & supplier of castings forging in carbon steel and alloy steel,is one of the large-scale professional investment casting production bases in China,consisting of both casting foundry forging and machining factory. Annually more than 8000 tons Precision casting and forging parts are exported to markets in Europe,America and Japan. OEM casting and forging service available according to customer’s requirements.

②How to guarantee the quality of the products?

We have established the international advanced quality management system,every link from raw material to final product we have strict quality test;We resolutely put an end to unqualified products flowing into the market. At the same time, we will provide necessary follow-up service assurance.

③How long can we receive the product after purchase?

In the purchase of product within three working days, We will arrange the factory delivery as soon as possible. The pecific time of receiving is related to the state and position of customers.Commonly 7 to 10 working days can be served.

 

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:What's the difference between a concrete pump and a concrete pump truck?
Concrete conveyor pump height and distance can reach hundreds of meters, which is far more than pumping vehicles, but it needs cloth tube, not flexible enough. Less investment.Pump car use more flexible, higher investment.
Q:Variable flow pumps are variable pumps
Yes. The variable pump is designed to change the flow rate
Q:Working principle and diagram of axial piston pump with pressure compensation variable
The size of the outlet flow pressure compensated variable displacement pump with outlet pressure of approximately in a certain range according to the constant power curve. When the pressure oil from the main part of the channel (a), (b), (c) into the inferior vena cava (d) variable shell, oil by the channel (E) respectively into the channel (f) and (H), when the spring force is greater than the oil (f) into the lower end of the piston ring servo hydraulic thrust area when the oil liquid (H) to the chamber (g), push the variable downward movement of the piston, the pump flow increases. As for the hydraulic servo piston end thrust force ring shaped area is greater than the spring when the servo piston moves upward, blocking channels (H), the (g) (I) through the cavity of the oil cavity pressure relief, at this time, the piston moves up, the variable head angle decreases, the pump flow rate decreases.
Q:What is the relationship between the minimum suction vacuum of a pump and the required cavitation?
Suction is allowed to pump the vacuum from the distance from the inlet, which is part of the field installation.The manufacturer of cavitation allowance is closely related to the design and process of pump. Estimation formula: cavitation allowance =10.33 meters - allow suction of -0.5 meters (safety).
Q:Because the water pressure of the booster pump is not enough, it can not work automatically. It can only be operated by hand. It is inconvenient to use.
The worst case is that the pump is not automatic when it leaves the factory, and no one can say whose product is 100%.But there may be automatic control of this piece, not debugging (this depends on the specific product manual or manufacturer)
Q:What happens when a centrifugal pump is selected?
First of all, the performance curve of the centrifugal pump is similar to the track of the train, and the train can not run away from the track.Secondly, the performance curves of centrifugal pump mainly include flow head curve, efficiency flow curve, power flow curve. When the pump is ready, the curve is fixed. In practical application, after determining the flow rate, the corresponding lift head, efficiency and power (relative to density) are determined. General requirements for centrifugal pump operating in the vicinity at the highest point of efficiency, the efficiency of the flow curve is similar to parabola, so if the actual operation condition deviated from the rated point, whether large or small, will cause the decline in pump efficiency (generally rated value is less than 15%), increased operating costs.
Q:Types and differences of pumps
(I) volumetric typeClassification reciprocating rotary typeThe basic principle of reciprocating action by the piston in the cylinder in the cylinder volume changes again, with the suction and discharge of fluid in the shell or the rotor rotating member rotates, the volume of work between rotor and casing changes to the suction and discharge fluid, such as piston pump gear pump, screw pump(two) blade type;The main structure of vane pumps and fans is rotary, bladed impellers and stationary housings that rotate fluid through the impeller to do work, thereby enabling fluids to obtain energy
Q:What is the "variable" of a variable pump?
There are many ways to change the variable pump flow: by changing the eccentricity to change the piston stroke length (radial piston pump, the frequency change principle) motor speed to adjust the flow (such as gear pump flow control principle).
Q:How to select the fire pump?
According to the water quantity form fire flow water supply system fire safety in high-rise building fire hydrant pump lift is 10L/s, accurate algorithm is to say after a simple calculation with each indoor hydrant flow is two 5L/s bolt so to get the most unfavorable point for the calculation unit to calculate the minimum requirements, with the most unfavorable point suppository pressure specifications 0.07MPa, partial loss of the most unfavorable line and the line (according to the equivalent length) and loss (according to the material resistance coefficient), and finally the pump head loss of gravity difference. But we just calculate the construction elevation difference multiplied by 110% to 120% to determine the head {there is a need to know is: conversion head (m), (kg) and MPa kg 1MPa=10 kg = 100m is the vertical water column on unit area pressure conversion
Q:Why do we need to stop the pump?
When the valve is closed, the flow of the pump is close to zero, the power of the pump is very small, which reduces the load that the motor starts to bear and has a protective effect on the motor. Therefore, the valve closed to start the pump.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range