Product Description:

Product overview

KWFB series sealing automatic self-priming pump, it is my company after repeated research of domestic and foreign similar products developed product. This product has the heat resistance, pressure, wear-resisting, "a drainage, life-long self-priming" and other functions and advantages. Under certain conditions can replace long axis pump, submerged pump, submersible sewage pump, etc. In the oil, electric power, chemical industry, steel, medicine, coking, electroplating, environmental protection, fire protection, municipal, water purification, national defense, textile printing and dyeing, mining beneficiation, widely used in civil construction and other industries, well received by users.

Application field

KWFB series sealing automatic self-priming pump, it is my company after repeated research of domestic and foreign similar products developed product. This product has the heat resistance, pressure, wear-resisting, "a drainage, life-long self-priming" and other functions and advantages, application of well received by users.

Product features

1, the use of the optimization design "polyhedral centrifugal pump with a serial type dynamic sealing device", abolish the traditional pump packing seal, mechanical seal, completely uniform "run, run, drip, leak.

2, in the operation of the seal friction, long service life than similar products more than 10 times, high reliability.

3, increase the outage sealing device, more suitable for frequent starting places.



Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Metering pumps related matters
2) change the metering pump diaphragmTrouble is often encountered when the old diaphragm is removed. Provide some additional advice on how to remove the old diaphragm.After in the pump head loose, remove the pump head before the stroke length adjustment to the 10% position. To ensure that the electromagnetic axis has sufficient pressure to maintain its connection firmly, so that you can unscrew the diaphragm.The pull end torque from the Jack out of the screw. Seize the liquid counter clockwise rotation. There is a slight resistance that can unscrew the diaphragm.Chemical 3 measurement may end in fluid crystallization, resulting in a one-way valve ball and seat valve does not work.In the end inhalation metering pump may have a gas leak. Hydraulic end suction side connector may lack O ring or suction valve connection loose.3) flow monitoring and measurement of a high viscosity medium, in the process of liquid delivery received a flow failure signal, how can we solve this problem?Move the hydraulic end by loosening the 4 pump head screws. Rotating stroke length to 10%, and seize the hydraulic end, and then slide out of the screw hole, then the screws do not touch them, but still control the back and diaphragm. Then rotate the component counter clockwise, with a slight resistance, and the diaphragm will loosen from the electromagnetic axis. If the diaphragm is not loose, use some grease on the contact surfaces of the diaphragm and the electromagnetic shaft. After a few minutes, gently tap the diaphragm with a small plastic hammer. Then proceed again in accordance with the above description.
Q:What are the main performance parameters of the pump?
The main performance parameters of the pump are:The energy obtained by pumping a unit weight of liquid through a pump. In H, the unit is m.
Q:What is a feed pump?
In general, high lift pumps are required with a front pump (which is similar to the feed pump of the landlord) or a low position;
Q:Does the control cabinet of the fire control pump need to be related to the fire control room?
The relationship is simple, the fire pump is pressurized water supply device, the control cabinet is the power supply for the fire pump, the regulator tank is to stabilize the pressure of the network management, reduce the pump frequently start device.
Q:How to select the fire pump?
According to the water quantity form fire flow water supply system fire safety in high-rise building fire hydrant pump lift is 10L/s, accurate algorithm is to say after a simple calculation with each indoor hydrant flow is two 5L/s bolt so to get the most unfavorable point for the calculation unit to calculate the minimum requirements, with the most unfavorable point suppository pressure specifications 0.07MPa, partial loss of the most unfavorable line and the line (according to the equivalent length) and loss (according to the material resistance coefficient), and finally the pump head loss of gravity difference. But we just calculate the construction elevation difference multiplied by 110% to 120% to determine the head {there is a need to know is: conversion head (m), (kg) and MPa kg 1MPa=10 kg = 100m is the vertical water column on unit area pressure conversion
Q:The suction pump has a nominal suction range of 30 metersHow deep can a well be sucked?Well, sixteen meters,
A standard atmospheric pressure can be 10.33 meters to 30 meters of water, suction is atmospheric pressure there are three standard atmospheric pressure so high? This is impossible in general, remove the vaporization removed 0.5 meters critical yo,
Q:What are the characteristics of the piston pump?
Piston pump is an important device of hydraulic system. It depends on the plunger in the cylinder in reciprocating movement, so that the volume of the sealing chamber volume changes to achieve oil absorption and oil pressure. Plunger pump with a rated pressure, compact structure, high efficiency and flow and easy adjustment, is widely used in high pressure and large flow and flow needs to adjust the occasion, such as hydraulic machine, engineering machinery and ships.
Q:What are the differences between the sewage pump and the clean water pump?
Sewage pump is a pump and motor conjoined, and at the same time submerged into the work of pump products, and general horizontal pump or vertical sewage pump compared to the sewage pump compact structure, small footprint.The water pump is for the transport of water and physical and chemical properties similar to water and other liquids used, suitable for the industry and the city water supply and drainage, water pressure high-rise buildings, garden sprinkler, fire booster, long-distance transportation, HVAC refrigeration cycle, irrigation, bathroom, cold and hot water circulation pressurization and equipment.
Q:What is the working pressure of the hydraulic pump in the hydraulic transmission system?
The choice of pressure depends on the size of the load and the type of equipment. Consideration shall also be given to the assembly space, the economic conditions and the availability of components for the actuators.In the case of a certain load, low working pressure, is bound to increase the structure size of the actuator on some devices, the size must be limited, from the perspective of material consumption is not the economy; on the other hand, the pressure to choose too large, the pump, cylinder, valve and other components of the material, sealing and manufacturing accuracy requirements very high, must raise the cost of equipment.
Q:How to calculate the motor power of metering pump?
Two Hydraulic power, metering pump rated flow (L/H) X, maximum pressure (Barg) / 36000 = kw

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range