Specification of Water Solenoid Valves

 

Medium

Air, water etc.

Temperature

-10°C to 80 °C

Pressure

0.03-1.6Mpa

Port size

3/8'-1'

Port thread

G.BSPT,BSP,NPT,PT

Orifice

12,15,20,25mm

Voltage

DC-12V,24VAC-24V,120V,240V/60HZ,110V,220V/50HZ

Tolerance

±10%

Coils

SA11B,9VA(AC),6W(DC) IP 65,100% ED

Special coils

Latching coil:DC6-24V as requested

 

Usage of Water Solenoid Valves

Water Solenoid Valve is commonly used in the fluid flow control system of control components, the solenoid coil as the driving source, used to rapid opening and closing a fluid channel and remote control. It usually consists of electromagnetic coil, iron core and the piston sleeve, sealing material, the body of four parts. The electromagnetic coil is the heart of the solenoid valve work. Solenoid valve on-off function of fluid pathway is via its internal dynamic core or the ascension of the piston and reset, and the action of moving iron core is composed of electromagnetic coil electricity and power outages.

 

Packaging & Delivery

Packaging Details : Plastic bags, boxes, cartons, and pallets.

Delivery Details:  5 days after receiving your payment

 

 

 

 

 

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:What are the electrical icons on the solenoid valve?
Electrical diagram superscript are symbols of action position with the electromagnetic coil of the electromagnetic valve between the valve and the control action, reaction medium (water, oil, gas and other media) relationship between flow, we can analysis of the working principle between them.
Q:Which part of the washing machine is in the washing machine?
The inlet solenoid valve of the washing machine is at the upper right corner of the washer panel.
Q:What is the difference between single and double solenoid valves?
double solenoid valve is double acting cylinder, without spring reset, two coil only one excitation, a push-pull working mode
Q:How is the electromagnetic valve linked with the pump?
Friends, if you want to pump and solenoid valve linkage, then the electromagnetic valve must be installed in the water outlet pipeline of the pump
Q:What power line should be used for the solenoid valve?
Solenoid valve is an electromagnetic control of industrial equipment, is used to control the automation of the basic components of the fluid, is an actuator, not limited to hydraulic, pneumatic.
Q:Duty cycle type solenoid valve operating principle
The duty cycle of the control pulse signal is determined by ECU, and the average current in the ECU magnetizing coil depends on the duty ratio
Q:What are the several points of the electromagnetic valve?
Position refers to the spool position: two is the spool has two positions, the three is that there are three positions, more than one in the middle position
Q:Selection of electromagnetic valve attention
Select the solenoid valve according to the pipe parameters: diameter specification (DN), interface mode
Q:How to use the two position five way solenoid valve?
Divided into single electric crane, double electric control, one hair can control a double acting cylinder
Q:Solenoid valve normally open and close normally
Normally open solenoid valve refers to the valve body in the role of the spring is open, and under the influence of electricity or external force to make the valve closed electromagnetic valve;
Our products include solenoid valves, bi-flow solenoid valves, discharge solenoid valves, thermostatic expansion valves, bi-flow thermostatic expansion valves, temperature responsive expansion valves, liquid injection valves, pressure controlled water valves, temperature controlled water valves, constant pressure expansion valves, pressure controls, differential pressure controls, temperature controls, flow switches and fluid sight glasses.On the bases of scientific management, we have developed a production base for refrigerating auto device with strong capability in design, production, and technical support and after-sale service.

1. Manufacturer Overview

Location Shanghai,China (Mainland)
Year Established 2000
Annual Output Value US$5 Million - US$10 Million
Main Markets 10.00% North America
10.00% Eastern Asia
10.00% Southeast Asia
8.00% Northern Europe
8.00% Domestic Market
8.00% South Asia
8.00% Oceania
6.00% Eastern Europe
6.00% Africa
5.00% Central America
5.00% South America
5.00% Southern Europe
5.00% Mid East
3.00% Western Europe
Company Certifications ISO 9001:2000;ISO 9001:2008;CQC(CHINA); CE(EUROPE); CE;CQC; High & New Technology Certificate

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port Shanghai
Export Percentage 51% - 60%
No.of Employees in Trade Department 3-5 People
Language Spoken: English, Chinese
b)Factory Information  
Factory Size: 3,000-5,000 square meters
No. of Production Lines Above 10
Contract Manufacturing OEM Service Offered Design Service Offered
Product Price Range Average