• variable frequency inverter 7.5kw  Chinsc industrial frequency inverter System 1
  • variable frequency inverter 7.5kw  Chinsc industrial frequency inverter System 2
  • variable frequency inverter 7.5kw  Chinsc industrial frequency inverter System 3
variable frequency inverter 7.5kw  Chinsc industrial frequency inverter

variable frequency inverter 7.5kw Chinsc industrial frequency inverter

Ref Price:
get latest price
Loading Port:
Qingdao
Payment Terms:
TT OR LC
Min Order Qty:
1 unit
Supply Capability:
3000 unit/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing


Introduction of SVF-G7 Series High-performance Vector General-purpose Frequency Inverter

 

1. Voltage class: 380V


2. Range of power: 0.4KW~450KW


3. Stable and reliable Control Mode


(1) VF control: Multiple curve could been chosen, Linear V/F curve, 2.0 times power drop torque V/F curve, custom V/F percentage(can realize manual energy saving control), multipoint VF curve. This apply to the situation that one frequency inverter drives multiple motors, such as fan, water pump, engraving machine, injection molding machine etc.


(2) Open-loop vector control: Steady speed with high precision, wide range of speed governing, as the speed ratio is 1:200 and 180% rated torque could be output in 0.5Hz. Good dynamic performance.

Open-loop vector is suitable for high-Performance universal occasions such as machine tools, centrifuges, cranes and handling equipment, rolling mill and other loads.



(3) Torque control: Fast torque response,<20ms, precision torque: <5%, applied to winding, drawing and other occasions.


variable frequency inverter 7.5kw  Chinsc industrial frequency inverter




Technical Parameter

 

Reckoned to be the quality-oriented organization, we ensure that clients are served efficiently most appropriate manner. Clients appreciate our range for their quality and easy availability, besides the reasonable prices. Suggestions of clients are always welcomed and we make changes accordingly if required. We ensure that queries of clients are solved in minimum time-frame with appropriate solutions.


.jpg





Trade terms

 

a. Delivery term

We will delivery for you after you done the full payment within 3  working days.

b. Payment

For small order by air or by express, it is 100% T/T in advance.

For large order by ocean, 30% deposit of the order value should be paid, 70% of the balance payment should be done before delivery.

c. Packing                            

Unless otherwise stated in the offer, the prices include packing in accordance with CHINSC’S customary standard of packing.

variable frequency inverter 7.5kw  Chinsc industrial frequency inverter



Applicable fields

Widely used in various fields such as metallurgy, petroleum, chemical industry, textile, power, construction material, coal, pharmacy food, paper making, plastic, printing & dying, lifting, cable making, washing, water supply, heat & ventilation, sewage treatment and son on. In addition the products can also be applicable to draw benches, mixers, extruders, winding machines, compressors, fans, pumps, grinding machines, belt conveyors, hoists and centrifuges.


variable frequency inverter 7.5kw  Chinsc industrial frequency inverter




Welcome your inquiry!

 

 

Looking forward to cooperating with you!


Q:The laptop power adapter is burned
If the power adapter is burned, you should check the laptop's power outlet, if the socket short circuit will lead to the power adapter burned. Maintenance method is not a power adapter and only use the battery boot try, can not boot, then the laptop itself is a problem, to send maintenance department maintenance; if you can boot, you can confirm that the power outlet is short, can be opened Laptop case, swap a new power outlet to solve the problem.
Q:I have a 5.5 kilowatts of 4-pole motor, want to pass through the inverter, slow down to 130 per minute use, eliminating the need for speed,
wo recommendations, the first, the use of vector control of the inverter, you are expected to run the frequency of about 5Hz, this time, ordinary V / F inverter output torque may be small, not necessarily meet the requirements, of course, if it is High-end imported inverter, the problem should be small, with the domestic vector inverter, the frequency can also be full torque output;
Q:5.5 kW 4-pole motor with the fastest speed can exceed the rated speed?
The speed of the AC motor is related to the frequency of the power supply. Frequency AC frequency of 50hz, asynchronous motor rated speed of about 1440 r / min, increase the frequency of course can improve the speed, naturally can exceed the rated speed, provided that the motor load to be reduced. If you need to improve more, need to replace the inverter motor, improve the motor heat dissipation characteristics.
Q:11kw 6-pole motor can be used to adjust the inverter to 1800RPM?
Frequency conversion frequency f to 90Hz can. 1800 = 60x90 / 3,3 that is 3 pole, is 6 pole. Regardless of load.
Q:Whether the inverter can control the start and stop of the horizontal monopole centrifugal pump
Inverter general control object is the AC motor, you are the AC motor, then the general inverter will be able to achieve start and stop, select a reasonable power section, a reasonable set of start and stop time can be very good drop protection motor. Can also achieve speed control function.
Q:Laptop power adapter problem
Second, the transformer This thing is not standardized production, the result is that even if the parameters of the same, the transformer to get another of this may not be compatible with the use of the explosion with the use of the cup like the situation, so we generally Stressed the original transformer.
Q:What is the difference when using inverter frequency conversion ordinary motor and variable frequency inverter motor
First of all you have to understand the difference between variable frequency motor and ordinary asynchronous motor. 1, inverter motor cooling fan is not connected with the motor spindle, is independent, the fan rotation from the motor speed, to ensure that the motor cooling.
Q:Will the 75KW4 pole motor can be used to increase the speed of the inverter?
China's power frequency 50hz, and the motor rated frequency match, blindly by increasing the frequency of the inverter output motor speed is not desirable, will affect the motor magnetic circuit, work is not normal.
Q:How to choose the inverter
I was doing the inverter, you choose the words, as long as 75KW can be selected, huh, huh, because the 1440 speed is fixed, the connection can be set in the inverter itself,
Q:How do I select a drive? Which brand is better
???4, when the inverter is used to control several motors in parallel, be sure to consider the inverter to the motor cable length of the sum of the inverter in the allowable range. If you exceed the specified value, to enlarge one or two steps to select the inverter. In addition, in this case, the inverter control mode can only be V / F control mode, and the inverter can not protect the motor over-current, overload protection, this time in each motor on the fuse to achieve protection. ????5, for some special applications, such as high ambient temperature, high switching frequency, high altitude, etc., this time will cause the inverter derating, the inverter need to enlarge a file selection. ????6, the use of inverter control high-speed motor, due to high-speed motor reactance small, high harmonics also increase the output current value. Therefore, when selecting a frequency converter for a high-speed motor, it should be slightly larger than the inverter of an ordinary motor. ????7, the inverter for the variable pole motor, should pay full attention to select the inverter capacity, so that the maximum rated current in the inverter rated output current below. In addition, in the operation of the number of pole conversion, you should first stop the motor work, otherwise it will cause the motor idling, bad will cause damage to the inverter.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Related keywords