Valve Non-rising Britain Stardard for Wholesales

Ref Price:
Loading Port:
Tianjin
Payment Terms:
TT OR LC
Min Order Qty:
50 pc
Supply Capability:
5000 pc/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

1.Structure of Gate Valve Description

A gate valve, also known as a sluice valve, is a valve that opens by lifting a round or rectangular gate/wedge out of the path of the fluid. The distinct feature of a gate valve is the sealing surfaces between the gate and seats are planar, so gate valves are often used when a straight-line flow of fluid and minimum restriction is desired. The gate faces can form a wedge shape or they can be parallel. Gate valves are primarily used to permit or prevent the flow of liquids, but typical gate valves shouldn't be used for regulating flow, unless they are specifically designed for that purpose. Because of their ability to cut through liquids, gate valves are often used in the petroleum industry. For extremely thick fluids, a specialty valve often known as a knife valve is used to cut through the liquid. On opening the gate valve, the flow path is enlarged in a highly nonlinear manner with respect to percent of opening. This means that flow rate does not change evenly with stem travel. Also, a partially open gate disk tends to vibrate from the fluid flow. Most of the flow change occurs near shutoff with a relatively high fluid velocity causing disk and seat wear and eventual leakage if used to regulate flow. Typical gate valves are designed to be fully opened or closed.When fully open, the typical gate valve has no obstruction in the flow path, resulting in very low friction loss.

 

2. Main Features of the Gate Valve

• Valve body cavity using non-toxic epoxy resin,both inside and outside flashboard completely is coated with rubber

•  Free of water pollution

• High manufacturing accuracy

• High strength

• Environmental protection and energy saving

• Good visual effect

 

3. Images

 

Valve Non-rising Britain Stardard for Wholesales

Valve Non-rising Britain Stardard for Wholesales


4. Gate valve Specification

 Valve Non-rising Britain Stardard for Wholesales

5.FAQ

1. What's are the characteristics of gate valve?

The distinct feature of a gate valve is the sealing surfaces between the gate and seats are planar, so gate valves are often used when a straight-line flow of fluid and minimum restriction is desired. The gate faces can form a wedge shape or they can be parallel. 

2. What is the work principle of gate valve

 The gate faces can form a wedge shape or they can be parallel. Gate valves are primarily used to permit or prevent the flow of liquids, but typical gate valves shouldn't be used for regulating flow, unless they are specifically designed for that purpose. Because of their ability to cut through liquids, gate valves are often used in the petroleum industry. 

3.  What is the structure?

Bonnets provide leakproof closure for the valve body. Gate valves may have a screw-in, union, or bolted bonnet. Screw-in bonnet is the simplest, offering a durable, pressure-tight seal. Union bonnet is suitable for applications requiring frequent inspection and cleaning. It also gives the body added strength. Bolted bonnet is used for larger valves and higher pressure applications.


Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Gate valve z41t what does that mean?
According to the provisions of the JB/T 308-2004 valve type programming method:Z = gate valve4 = connection form: flangeT = sealing surface material: copper alloy
Q:What are the working principles of the electric gate valve?
You see what type of electric valve, is integral or ordinary type, if the overall type Denso took power on the line, is generally 380V and 220V power supply, and then according to their own needs and then open the signal line, in place and closing in place and remote control line, valve position feedback signal 4~20ma over torque protection, fault signal. Ordinary type electric valve should be equipped with the control box, the motor is the true story and the inversion, and in general to a trip signal signal is normally open and normally closed, closed in place are normally open and normally closed two points according to their own needs wiring, three lines and then open and close control of the line of control there are also 4 lines to control some manufacturers, as well as the valve position, some three lines connected with the potentiometer, some installed valve position transmitter is connected with two lines, and over torque protection fault signal.
Q:What is the difference between the cut-off valve and gate valve, the general will use the cut-off valve instead of gate valve
Stop valve and gate valveThe working principle is different. The stop valve is an upward stem type, and the handwheel rotates and rises with the stem. Valve is hand wheel rotation, stem upward movement. Flow is not the same, the gate valve requires full open, the cut-off valve is not the same. The gate valve has no inlet and outlet direction requirements, and the cut-off valve has the required inlet and outlet!Gate valve and stop valve are shut-off valve, is the most common two valves.From the exterior, the gate valve is shorter than the cut-off valve, especially the bar valve needs a higher height space. Valve sealing surface has a certain degree of self sealing capacity, its spool depends on the media pressure tight contact with the valve seat sealing surface, to achieve tight leakage. Wedge gate valve spool angle is generally 3~6 degrees, when forced to shut down excessive or temperature changes of the valve core is easy to die. Therefore, high temperature and high pressure wedge gate valve, in the structure have taken certain measures to prevent spool stuck. The valve in the opening and closing valve and valve seat sealing surface contact and mutual friction is always so easy to wear sealing surface, especially in close off the valve, the valve before and after the great pressure, sealing surface wear is more serious.
Q:How about the model of stainless steel gate valve?
Stainless steel gate valve is divided into 304 stainless steel gate valve, 316 stainless steel gate valve, 321 stainless steel gate valve. The expression is: Z41H-16P.
Q:HVAC design, why is less than DN50 of pipe gate valve and cut-off valve,
It's not the valve! But the price relationship!
Q:Analysis of the advantages of elastic seat sealing gate valve?
When the elastic seat sealing gate valve is closed, the sealing surface can be sealed only by the medium pressure, that is, the sealing surface of the flashboard is pressed to the valve seat of the other side only by the medium pressure to ensure the sealing of the sealing surface, which is self sealing.
Q:The legend of gate valve and stop valve
Compared with the cut-off valve, the main advantage is that the flow resistance is small, the flow resistance coefficient of ordinary gate valve is about 0.08~0.12, while the ordinary cut-off valve resistance coefficient is about 3.5~4.5. Opening, closing force is small, the medium can flow in two directions. The disadvantage is that the structure is complex and the height is large. The sealing surface is easy to wear. The sealing surface of the valve must be forced to close the valve to achieve sealing, in the same caliber, work pressure and the same drive device, the drive valve torque is 2.5~3.5 times the gate valve. This point should be noticed when adjusting the torque control mechanism of the electric valve.The sealing surface of the stop valve contacts each other only when the valve is completely closed, and the relative sliding amount between the valve core and the sealing surface is very small, so that the wear of the sealing cover is very small. The sealing surface of the valve cover, mostly due to the spool and sealing surface before the debris, or because of the closed state is not tight, causing the medium of high-speed erosion caused by.
Q:What's the difference between a soft seal gate valve and a hard sealed gate valve?
Soft sealing gate valve is rubber seal, F sealed, hard sealing gate valve is the medium of particles.
Q:How big valves and fittings need flange installation, such as gate valves, DN50, DN80 and the like?.
Flanges for piping above DN50,DN50 (below) can be made of wire or flange (flange for pressure piping)
Q:What's the meaning of flexible z45x-10q door valve?
Crown valve pressModel Z45X-10QZ refers to gate valve4 finger flange connection5 refers to the dark bar driveX refers to rubber seals10 refers to 10 kg pressureQ refers to the body material, ductile ironFull bore flange soft sealed gate valve

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range