DN700 Gate Valve

Ref Price:
Loading Port:
China Main Port
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
-

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Technical Date

Material Specification

Nominal Diameter

DN50-DN600

Valve Body

Ductile Iron QT450-10

Nominal Pressure

PN10/PN16

Hand Wheel

Operation Temperature

-40°C~225°C

Bonnet

Flange Driling Standard

EN 1002-2 PN10/16

Gland Flange

Suface Treatment

Akzo Nobel Fusion Bonded Epoxy

Stem

2Cr13/ss410

Seal Material

EPDM or NBR


Application

Portable water, water distribution service & feed lines, sewage disposol, irrigation, fire protection pipe systerm, etc.

Wedge Nut

Carbon Steel

Thrust Washer

Brass

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:What is gate valve (with force transfer joint)?
The force transfer joint is mainly used for the loose connection of pumps, valves and other accessories.
Q:The difference between flanged gate valve and common gate valve
General diameter of more than 50 with flanges, inspection wells, main pipes, trenches... Must use flange gate valve, good operation, good replacement.
Q:Does the tap belong to a stop valve or a gate valve?
Most faucets are stop valves,Part of the faucet is plug valve,Hot water nozzles are almost all plug valves.
Q:What is the difference between Z41X gate valve and Z45X gate valve?
There is no difference in function. The two models are mainly made of different sealing materials,
Q:Gate valve type Z40Y, Z40H letters - what does that mean?
According to the provisions of the JB/T 308-2004 valve type programming method:Z== gate valve4== connection: flange0== structure: wedge type elastic RAMY== sealing surface material: hard alloyH== sealing surface material: Cr13 stainless steel
Q:What is the difference between cut-off valve and gate valve?
Simply put, the cut-off valve is one-way, only into, do not give up, the valve is two-way
Q:What are the specifications of the gate valves? Does the work pressure need to be marked separately?
According to domestic valve model standards, the valve model is by the valve type, gate valve drive mode, gate valve connection, gate valve structure, sealing material, valve body material code to indicate.1, gate valve type code named Z;2, gate valve drive mode code by letters, common 2- electric hydraulic, 9- electric, 6- pneumatic, 5- bevel gear drive, 3- turbo worm; manual do not need to write out;3, gate valve connection form code with letters to indicate, 1- internal thread, 2- external thread, 4- flange type, 6- welding, 7- pairs clamp type, 9- clamp, 0- card sleeve;4, the valve structure of code, 0- flexible wedge, 1- rod single wedge gate valve, 2- rising stem wedge gate valve, 3- parallel single gate valve, 4- parallel double gate valve,
Q:What type of flange does it fit with the gate valve?
This depends on the type of gate valve, valve standards are marked with matching flange standards. Different types of flanges for different gate valves are also different.The flange of General GB gate valve is GB/T9113 series.
Q:What are the meaning of the cast rigid gate valves z41h-16c?
According to the provisions of the JB/T 308-2004 valve type programming method:Z== gate valve4== flange connection1== rigid single gateH== sealing surface material: Cr13 stainless steel16== pressure rating: 1.6MPaC== body material: carbon steel
Q:Function of gate valve
Gate valve is a closed (gate) along the central line of the vertical direction of the valve moving. Valve in the pipeline can only be fully open and fully closed off, can not be adjusted and the throttle. Gate valve is a valve used in a wide range, generally more than 50mm caliber DN block device is selected it, sometimes cut off very small aperture devices are used to gate valve, gate valve is used as cut-off media, when in full flow through the whole, when the media is running a minimal pressure loss. Gate valves are normally used in situations where they do not need to be frequently opened and closed, and the gate is fully open or fully closed. Not used as an adjustment or throttling. For high speed moving medium, the gate can cause the vibration of the gate under the condition of partial opening, and the vibration may damage the sealing surface of the gate and the valve seat, while throttling will cause the gate to suffer the erosion of medium.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range