T8 LED glass tube, 13W, 68leds/900mm, 1150lm, SMD3528,G13,Ø26, AC180-260V,Constant current driver, White6500K,Warm white3000K,CE

Ref Price:
Loading Port:
China Main Port
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
-

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

T8 LED GLASS TUBE





1. Parameter:









 





Haoyue Series Model: 




LED FL-13W-F3-HY68 LED/900 MM




 




Input Voltage  (V):AC 180-260V




Power (W) :13W




Current (A)0.12A




Degree of  Protection (IP) :IP20




Material :SMD 3528




Max. Op. Temp.  :40℃




Ambient Temp.  :-10℃-40℃




Ambient  Humidity :35%




Power Factor :0.6




LED Luminous  Flux (lm) :1150lm




Beam Angle  (degrees) :320°




Luminous  Efficacy (lm/watt) :85




Color  Rendering Index (Ra) :72




Average Life  (hours) :20000




Lamp Body  Material :Glass




Lamp Holder:G13




Size  (diameter):Ø26




Power :Built-in  Isolating Source 



Driver Model:Constant Current  Driver




Color and  Colour Temperature:White 6500K , Warm White   3000K


















Spec.A    Max(mm)B     Max(mm)B     Min(mm) C    Max(mm)Ø               (mm)
LED FL-13W-F3-HY894.6901.7  899.3  908.8  26








5. Key  Specifications/Special Features:

Features:

1) LED tube  integrates a LED light source into a traditional fluorescent form factor

2) Its unique design creates a perfectly uniform visual  appearance, which cannot be distinguished from traditional fluorescent tube  light

3) This product is  the ideal solution for up lamp in general lighting applications

4) The LED tube is  an affordable LED solution suitable for replacing T8 fluorescent lamps

5) The product provides a natural lighting effect for use in  general lighting applications, as well as instant energy-saving, an  eco-friendly solution

6) Designed to replace fluorescent T8 tubes, the LED T8 offers  an incredible lighting performance that reduces both electricity and  maintenance costs

7) With the long lamp lifespan and wide range of operating  temperature, it is ideal for applications such as offices, warehouses, car  parking, factories and kitchens








6.  Benefits:

1) Direct  replacement retrofit for fluorescent T8 tubes at much low-energy consumption

2) For retrofit on conventional magnetic ballast circuits by  simply exchanging the starter in the installation with the dummy start  supplied with the tube

3) Excellent  heat-dissipation

4) No buzzing  noise, fluorescent flickering and RF interference

5) Eliminates dark  regions at both end of the T8 tube

6) High-lumen  maintenance















7. Installation Instruction


















 






















































































































































































8.  INSTALLATION DIRECTIONS:




1. Before installation, please read instruction carefully and  preserve it well.
2. Only maintained and installed by qualified electrician.
3. Before installation, please cut off the main power.
4. Do not connect the lamp to main supply until installation is  completed.
5. Please DON’T USE LED TUBES with BALLASTS and STARTERS.
6. Please follow the Connection Schema for correct connection.  Make sure the appliance has been mounted safely.







9. CAUTION:      
1. Turn off the switch when replacing and cleaning.
2. Wipe lamp with a dry duster.
3. Do not use any chemical duster or solvent such as oil or  thinner.
4. Do not spray insecticide on this lamp.



Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:How to detect the good and bad of the fluorescent lamp
There is a small filament in each end of the normal daylight lamp, and the two feet on each side of the lamp are interlinked with the multimeter (only very small cold resistance). Working principle is: making after vacuum tubes when filling the silver (mercury), a small drop of water on the walls painted with fluorescent powder, the bulb is started, at the ends of the filament after heating, mercury evaporates into gas, gas is ionized conductive lines into loop, gas release a large number of ultraviolet (uv), at the same time by the ultraviolet radiation fluorescent powder from visible light. In addition, when after the lamp aging on both ends of the filament evaporation guide to black on both ends of the tube, the tube sometimes no broken cannot use the filament lamp to glow (so).
Q:What is the weight of an LED fluorescent tube
I bought the T8LED fluorescent lamp from Shanghai shuo electronics co., LTD., which is 536 grams
Q:The circuit board in the LED fluorescent tube, what's the name of the component?
Hello, I have the same question as you, and this board, I wonder what the components of the unit are called?I hope my answer is useful to you.
Q:Who knows about the fluorescent light of 40w, how many w's LED bulbs can replace or exceed its brightness?
If you have 40 watts, if the length is 1 meter 2, it should be a T81.2 length LED fluorescent tube. You can measure the length of the lamp with a tape measure. When I changed to LED16.5 watts, I was the equivalent of 60 watts of traditional energy-saving fluorescent bulbs. The brightness must go beyond that
Q:How to replace old lamp tubes with LED tubes
The leds that appear on the market today should be connected directly to the 220V power supply. Control the power supply inside the lamp. LED fluorescent lamp, does not need a ballast, regenerator. Replacement methods: The starter of the traditional fluorescent lamp directly to the holder, to all the ballast output input line cut off, and then in the 200 v 2 wire, a root to the fixed base, a fixed socket to the other side, and just cut it off and pick up good, insulating tape, and then install the LED fluorescent lamp. The town can't go down, but now he's no longer working and he doesn't consume electricity.
Q:Feasibility analysis report of LED lamps
A: hello, may I help you? Is the report for the government? I have contact information in my profile
Q:What causes the red light on both ends
On both ends of the fluorescent lamp with a filament, when using the filament with a long time because of the heat for a long time makes its internal metal tungsten evaporates and attached to the fluorescent lamp on the wall of darkened, and so you turn on the light because the light on the wall that had led to that piece of dark red.
Q:What are the details of the whole process of the LED lamp?
When you do the rules, the key parts need you to provide some certificates, and you need to be careful with the suppliers
Q:Does the power drop when the lamp of fluorescent lamp declines
Because daylight through the electric current is determined by the current limit (ballast), so the lamp how basic will not affect the size of the total current, so what it consumed power will not change.
Q:Daylight lamp tube is broken, does not clean can be bad? In the office
It contains mercury vapor, which is bad for the airway, and it's better to disturb, not to smell

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range