T5 Led Tube Light Fixture

Ref Price:
$1.00 - 8.00 / pc
Loading Port:
Shanghai
Payment Terms:
L/C,T/T
Min Order Qty:
200 Pieces pc
Supply Capability:
200000 Pieces pc/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

T5 Led Tube Light Fixture

 

Product Description

Certificates: CE, RoHS

Product Features:

  • Ø  High Energy Efficiency: Low Power consumption, energy saving;   

  • Ø  Reliable Quality:

    • Good heat dissipation with professional designed aluminum housing

    • Built-in constant current driver

  • Ø  Aluminum body and milk PC cove

  • Ø  Working Temperature: -20~+55°

  • Ø  Eco-Friendly: No UV and infrared radiations

  • Ø  Long lasting life, up to 50,000hrs

  • Ø  Easy Installation: can be directly replaced to G13based fluorescent  lamps

 

Product Specifications:

 

Specification Sheet for T5 LED Fixture
Model NumberT5LED-TS07-1500T5LED-TS07-1200T5LED-TS07-900T5LED-TS07-600
Voltage90-265V/50/60Hz
Nominal Power28W18W14W8W
Rated Power28±0.5W18±0.5W14±0.5W8±0.5W
LED ChipSMD2835 130pcsSMD2835 104pcsSMD2835 78pcsSMD2835 48pcs
DriverIsolated Constant Current Driver 
PF0.90.90.90.9
Color Temprature3000/4000/5000/6000K
Lumen/Watt85-90LM/W85-9085-9085-90
Total Lumens2380-2520LM1530-1710LM/W1190-1260LM/W680-720LM/W
Ra≥70≥70≥70≥70
Beam Angle120°
HousingAliminum Housing + PC Cover 
End CapsPC end cap, three pins
Product Size 1500x23x32mm1200x23x32mm900x23x32mm600x23x32mm
Inner Packing Size1530x40x28mm1240x40x28mm930x40x28mm630x40x28mm
PCS/CTN25252525
Master Carton1550x215x165mm1250x215x165mm950x215x165mm650x215x165mm

 

Packaging & Shipping

 

Packing:

  • One piece in one polybag;

  • One polybag in a individual carton

  • 25pcs in a standard export carton

 

Inner Packing Size1530x40x28mm1240x40x28mm930x40x28mm630x40x28mm
PCS/CTN25252525
Master Carton1550x215x165mm1250x215x165mm950x215x165mm650x215x165mm

  

Shippings: 

  • By express: Such as DHL,UPS, TNT, FEDEX ect. The dispatch time is about 3-5 will search for a economical shipping  company to transport the goods safely

  • Air Freight: When you order more than 100kg which will be more economical than express,

  • Sea freight: We will update sea freight later once we know to which sea port goods will be delivered

  • Agent designated by client: Please tell us the contact details of your shipping agent/forwarder

     

Our Services

  

Sample Service:

Small quanitty of sampels are free of charge, buyer shoulder the freight cost

Sample delivery time is around 3-7 days after confirmation

Customized Service 

We accept OEM order and we can help customer design

We also offer ODM service to customer when needed

After-sale Service

We offer 7/24 Service

Any quality issue, once confirmed is our responbility, we will compesate our customer.

 

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:The difference between an LED tube and a daylight lamp
A diving LED tube is usually blue. You are? This light is useful for red grass and sea water tanks. You don't need a koi. If you want to use a white LED lamp mixed with a light-colored LED lamp or a red, blue and green light bulb. Red, blue and red blue (purple) mixed light is bad for viewing. Add a white light blend. You can't raise the two kinds of fish that you raise, and you don't have a lot of light on the lights. As long as it doesn't affect the view, it can continue.
Q:Is there a greater value in switching from a normal daylight lamp to an LED energy-saving lamp?
I can give you a detailed example of your problem: LED fluorescent lamp tube 6w can replace the normal daylight lamp tube 20w, 9w can replace 30w, 12w can replace 40w, 15W replace 45W, 18w can replace 60w, save more than 70% electricity; LED life can theoretically reach 5-100,000 hours, nearly 10 years. Q: how much electricity do you need a year if your company owns 10,000 40W, regular daylight bulbs (plus a rectifier, for example, 46-49 watts)? A: common light bulb: 365 days * 15 hours * 46w * 10,000 lamp tube / 1000W (1 hour) * charge 1 yuan = 2518500 yuan. LED bulbs: 365 days * 15 hours * 12W * 10,000 tubes / 1000W (1 hour) * charge 1 yuan/degree = 657,000 yuan. On the data, the cost can be recouped within a year, saving as much as $3 million in electricity bills within three years.
Q:The lamp tube of LED lamp is full plastic lamp tube good or half plastic half aluminium tube good?
The whole plastic lamp tube is the one of the most early application, because the main use is not isolated type power source, in order to avoid electric shock problem, so more want to adopt whole plastic lamp tube. It USES a phi 5 hat tube LED. The fluorescent lamp the biggest problem is that the cooling problem, because all the heat sealed in tube, don't spread out, the light failure is severe, plus straw hat tube original life is very short, less than 2000 hours it broke.
Q:Does the LED lamp need to be a national compulsory certification
Do not need, at present domestic do not have mandatory certification, domestic also do not have a unified standard and index! At most, there is the certification of the eu system, ce and rohs. In fact, leds are the most energy-efficient way to make a comparison: We compare 1.2 meter ordinary fluorescent lamp with 1.2 meter LED fluorescent lamp consumption By 20 hours per day: The average fluorescent lamp has a life expectancy of two years, LED fluorescent bulbs have an average life span of six years (the LED fluorescent tube has a lifetime of 4,3800 hours). The 12WLED fluorescent lamp is comparable to a 40W standard fluorescent lamp.
Q:How do the fluorescent tubes fail?
It's not hard to repair, it doesn't have the value of maintenance.
Q:I have LED lights on fluorescent lamp tubes, and I have tested five times a dc
Let's say a light bead is working at 3v voltage and the current is 300ma. To get it to 3.1 volts, the current can reach 400ma. 220v market volatility is large (200-250) sometimes higher. At the very least, you need to add resistance.
Q:How do you measure the flux of the LED fluorescent tube
In theory, it's measurable, and it's actually hard to set up. There are two ways of measuring flux, essentially the same thing 1: the integrating ball is measured by your illuminometer 2: set up the field aperture + your illuminometer + space station to measure by the 4PI () stereo Angle integral. The last time you said you have integral ball and light meter I suggest the first way is feasible. In addition you put not fluorescent lamp it doesn't matter, can be measured in area of block of luminous flux, and finally take the area integral. The results must be less than professional distribution photometer to measure, the standard but the data still have rigorous theory and process support.
Q:Buy LED fluorescent tubes to see which parameters
Led fluorescent bulbs are recognized and accepted for their health and energy efficiency. But, as a ordinary consumers or less of the professionals in the choose and buy leds, there may be some doubts - what a lamp is better, is suitable for use in yourself! As a professional manufacturer of led fluorescent lighting, hill photoelectric has some Suggestions for reference only. Constant current, no flash Led voltage is determined by the chip itself, and the resistance is in with the rising of temperature change, if not using constant current power supply, Led the current will increase, more than rated current job for a long time, can greatly shorten the service life of the Led. An LED constant is a constant flow of temperature and voltage, ensuring that the current is constant. And constant current, can let lamps and lanterns not stroboscopic.
Q:How long does the energy-saving daylight lamp tube change?
If a square originally needed a single one to reach the requirement, it now needs to be increased to three to achieve the original brightness. It's normally 3X36 = 108 watts per square root of 36 watts. It turns out that electricity consumption is only 0.036 degrees per hour and now it is 0.108 degrees to achieve the same brightness. The more you open it, the more energy you will consume. Besides, this is without causing damage to the case, the general tubes to use fixed number of year will gradually damaged, bad time change time will be more trouble, so as to compare and calculate a one-time change.
Q:How to remove fluorescent lamp tube
Turn off the daylight power supply; Two, the old daylight lamp two have a gap at the end of the rotation 90 degree, the double needle pulls out from the gap, the other end pulls out. Three, the old electronic rectifier without gap, is elastic, right hand hold to the right of the plastic head, left hand hold tube push 1 centimeter or so, to the right lamp tube needle left out at this moment, at the same time left hand move down the left tube face, left hand to pull in front of the tube to the left. If it is an LED tube aluminum alloy, you want to remove the contents of the inner tube, both of which have two cross screws, and the screwdriver can be removed. The leds that do not understand the electrons should not be removed. Five, the LED lamp that still has glass in the market at present, this kind of is one-time, two is to use the bad of glue stick to be thrown away, have no maintenance value. Don't take it down and you may hurt your hand.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range