Split Casing Pump for Channel Irrigation

Ref Price:
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 set
Supply Capability:
10000 set/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

 

                Split Casing Pump for Channel Irrigation

1.Structure of split Casing Pump for Channel Irrigation Description

The Single Stage Double Suction Split Casing Centrifugal Pump is designed for Irrigation, The casting is axially split, which permits removal of the complete rotor whish moving either piping or motor. Pumps generating high heads have double volute to reduce radial forces. Replaceable wear ring protect the casting at the impeller running clearances. Flange drilled to ISO, DIN, BS or ANSI. The close double suction impeller gives practically zero axial forces. Each impeller is statically and dynamically balanced according to ISO 1940.The pumps have a reduced number of parts and extensive interchangeability, which leads to minimum levels of inventory for customers and faster parts delivery. Vertical installation is a standard option with the same upper and lower casing parts. It is mounted for a space-saving configuration or when apace is at a premium. Soft packing or mechanical seal, grease or oil lubricated bearing is optional. Oil lubrication is with constant level oiler.

 

2.Main Features of the Single Stage Double Suction Split Casing Centrifugal Pump

Compact structure

Attractive design

High efficiency, steady performance

big capacity, medium pressure

High concentricity of components

3. Single Stage Double Suction Split Casing Centrifugal Pump Images

Split Casing Pump for Channel Irrigation

4. Single Stage Double Suction Split Casing Centrifugal Pump Images Specification

Material 

Cast Iron, Ductile Cast Iron, Cast Steel, Stainless Steel or Duplex S.S

Impeller

Cast Iron, Bronze, Duplex S.S, Stainless Steel

Shaft

C-Steel, Cr-Steel, Stainless Steel

Wearing Ring

Cast Iron, Brass, Stainless Steel

Capacity/Q

Up to 25000m3/h,

Up to 110000gpm

Head/H

Up to 280m,

Up to 800 feet

Temperature/T

Up to 200degree

Speed/n

2900/1450/980/740/580 rpm

3500/1750/1180/890/710rpm

5.FAQ

What is the applications

Besides irrigation and drainage pumping Station, the Single Stage Double Suction Split Casing Centrifugal Pump also can be used for Circulation water for air-condition, water supply for industry and building, and other waterworks

How to guarantee the quality of the products

We have established the international advanced quality management systemevery link from raw material to final product we have strict quality testWe resolutely put an end to unqualified products flowing into the market. At the same time, we will provide necessary follow-up service assurance. Normally, We have 1 year warranty.

How long can we receive the product after purchase?

In the purchase of product within three working days, We will arrange the factory delivery as soon as possible. It related to the state and detailed requirement of customers.

 

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:What is the difference between centrifugal pump and positive displacement pump?
The centrifugal pump is usually driven by an impeller, and the head has a functional relationship with the flow rate. Positive displacement pump is gear or piston drive, each stroke output flow is constant, and the head does not matter, the pressure head can be infinite.
Q:Is vane pump good or gear pump good?
1) the reversible design of gear pumps can also usually reverse, but reverse after the suction port change, and the pump safety valve does not work; leaf pump is generally not allowed to reverse. 3) the single acting vane pump can be designed to change the eccentric distance by moving the stator at the constant speed, so as to achieve the purpose of variable direction.
Q:What is the pump lift voltage? And how to suppress the pumping voltage rise?
[pump voltage] when braking, in the motor winding series resistance, motor equivalent to the generator, the energy will be converted to electric energy consumption in the series resistance. This method is widely used in all kinds of motor braking, and frequency conversion control is also used. From high to low (zero speed), then the electrical frequency changes quickly, but the rotor of the motor with the load (production machinery) mechanical inertia, could not stop quickly, resulting in the back EMF (EU voltage) motor is in the state of power,
Q:What are the conditions required for hydraulic pumps to complete oil absorption and compression?
2, the change of working volume is periodic, and in each cycle, the oil absorption process is changed from small to big, and the process of oil pressure is changed from large to small;3, suction oil cavity must be separated from each other without interference.
Q:How many millimeters is the diameter of the water outlet of the four inch pump?
If it is a centrifugal pump, the nominal diameter of the outlet is less than 4 inches, there is a conical short tube to enlarge the standard 4 inch outlet flange, from here, is the standard 4 inch flange connection.
Q:What does "efficiency" mean in a water pump catalog?
General pump efficiency is 60% ~ 85%. high efficiency of the pump, indicating the same work, the pump consumes the lowest energy, and vice versa
Q:Why is the sewage pump device coupler?
Advantages of installation and arrangement of sewage pump coupling:1. automatic coupling device, easy installation and maintenance. In the absence of automatic coupling device under the condition of fixed installation, such as pump fault maintenance personnel need to unscrew the screw pump lifting water, repair, or other small pump to pump the water down perfect maintenance, if the water is dirty, it would be difficult for people to go to the next, then the overhaul had great difficulty.
Q:How can the submersible pump level meter be connected?
Install liquid level controller, two position liquid level sensor, controller to buy manual, wiring according to wiring diagram.
Q:Difference between pump and compressor
A pump is a machine that transports liquids or pumps liquids. It transfers mechanical energy or other external energy of the prime mover to the liquid, increasing the energy of the liquid. The pump is mainly used to transport water, oil, acid and alkali liquid, emulsion, suspension emulsion and liquid metal, and also can transport liquid, gas mixture and liquid containing suspended solid. Pump can usually be divided into three types of displacement pumps, power pumps and other types of pumps according to the principle of operation. In addition to classification according to the working principle, it can be classified and named according to other methods. For example, according to the driving method can be divided into the electric pump and the turbine pump; according to the structure can be divided into single-stage pump and multistage pump; use can be divided into the boiler feed pump and the metering pump; according to the nature of transmission fluid can be divided into water pump, oil pump and mud pump etc.. In accordance with the non axial structure, can be divided into linear pumps and traditional pumps.
Q:How to select metering pump head?
In metering fluoride, we recommend the use of Viton, sealed PVC pump head. For most chlorination applications, it is better to use EPDM sealed NP (plexiglass) pump head. For hydrogen peroxide mixtures, only PTFE sealed PTFE pump head or stainless steel pump head can be used

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range