Product Description:

◊ Application

Applied to pumping such liquid which is clean, no solid matter or frictional matter, low viscous, noncorrosive, non-crystallizable, chemically neutral and close to water. Such as:

1.  Tank filling

2.  Domestic water supply

3.  Water transfer

4.  Pressure boosting

◊ Features

1. 100% copper wire, and automatic wiring.

2. Cold-rolled silicon steel sheet, with high-speed punching, improve the efficiency and precision.

3. Demagnetization of stainless steel nuts.

4. Anti-rust treatment castings and electrophoresis.

5. New testing equipment.


◊ Technical data

1. Suction lift up to 9 m
2. Liquid  temperature up to +35°C
3. Ambient temperature up to +40°C
4. Max. Working pressure: 6 bar



Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:What is a positive displacement pump? He Weizheng displacement?
The principle and structure of displacement pumps are similar to those of hydraulic motors. Positive displacement is the pump outward to provide flow and pressure, that is, conventional pumps. A negative displacement pump is a hydraulic motor that rotates by external pressure and flow
Q:Pneumatic diaphragm pump compressed air pressure is 4 kg, the discharge pressure is how big?
Pigment pressure is less than 0.4mpa,About 0.3. Go up.As the pump diaphragm is in the middle of a connecting rod, equivalent to the cylinder cavity, the pressure will be reduced; and because of the loss of pigment tube pressure will be reduced.
Q:The working principle of magnetic pump
Control of cooling fluid flowThe pump is running, you must use a small amount of liquid in the magnetic separation between the rotor and the casing annulus area and sliding friction bearings for flushing cooling. The cooling liquid flow pump design flow is usually 2%-3%, the annular area between the magnetic rotor and sleeve of eddy current generated because of high heat. When the cooling and lubrication the liquid is not enough or poor flushing holes to plug, will result in permanent magnet medium temperature is higher than the operating temperature of the inner magnetic rotor gradually loses magnetism, the magnetic actuator failure. When the medium is water or water-based liquid, can make the annulus area temperature maintained at 3-5 DEG C; when the medium or hydrocarbon oil that can make the annulus area temperature maintained at 5-8 degrees.
Q:Water pump outlet valve sequence
In order to prevent the generation of water hammer when the pump stops the damage to the rubber head, should be immediately set rubber head pump outlet, the gate valve and the check valve is not a very convincing reason to decide the order of habits in our hospital order rubber head, check valve, gate valve1. Check valve located in front of the pump, I do not know what the significance is too great to think of.2. The actual installation sequence shall be: soft fittings, check valves, gate valves. The pressure gauge is best installed on the water outlet of the pump, but it must be in front of the check valve.Reason: 1) the soft joint is used to reduce vibration. The connection between the pump and the piping system, of course.2) normal work, the gate valve is not operating, and the check valve is frequent action, so the probability of maintenance is larger, when the maintenance of the pump closed, the water outlet valve can be maintained without affecting the normal operation of the system.3) the pressure gauge is installed in the check valve, which can prevent the impact and damage of water hammer on the pressure gauge.
Q:How many square cables does the submersible pump for 7.5KW need?
I=P/ (1.732Ucos phi) =7.5/ (1.732X0.38X0.85) =13A (calculated according to three-phase city power, power factor 0.85).
Q:How do vacuum pumps and pumps work together?
The role of the check valve:"[the water pump impeller is not closed" refers to the pump suction pump before the water without water inlet pipe and water outlet pipe gas should be connected] is a connector, a connector, still can make the level surface, in order to prevent the water flow along the pipe, until it reaches the level of the flush, then increased check valve.
Q:Why does the centrifugal pump start with a closed valve and the axial pump starts with an opening valve?
Because the characteristic curves of the two are different.The power of centrifugal pump decreases with the decrease of flow rate. When the flow rate is zero, the power is minimum, so the centrifugal pump is started with a closed valve.
Q:How many millimeters is the diameter of the water outlet of the four inch pump?
Here is a 4 inch inch, not rural, 1 inches =25.4 mm, 4 inches is approximately 100mm, with DN100 pipeline.
Q:Advantages and disadvantages of centrifugal pumps?
Centrifugal pump; advantages and disadvantages:(1) advantages:The structure of the pump is simple and compact, and the centrifugal pump has small area, light weight, little material consumption and high cost for the foundation. Therefore, the cost of manufacturing and installation is less.For high speed operation, the 2 pole or 4 pole motor can be directly connected. The drive structure is simple and easy to install.
Q:What is the lift of diaphragm pump?
Tell you: diaphragm pump head is liquid through the pump energy obtained is called lift it, and flow and pump speed, a liquid density is generally 1 kg is 10 meters lift, horizontal pipeline 10 meters 1 meters lift, a 90 degree bend is 1 meters.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range