• ISG Vertical Centrifugal Water Pumps System 1
ISG Vertical Centrifugal Water Pumps

ISG Vertical Centrifugal Water Pumps

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
-

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

ISG series vertical pipeline cooling water centrifugal pump

Performance Parameters :

a) Caliber: DN40-DN125mm
b) Flow: 2.8-100m3/hr
c) Head:3-38 m
d) Rotate speed:  1400,1450r/min
e) Viscosity: ≤100mm2/s

g) Motor power:0.12-30 KW                                                            

h) Working temperature: ≤100°C

ISG series vertical pipeline cooling water centrifugal pump

    ISG series single stage single suction pipeline centrifugal pump is designed on the base of

    domestic execellent water power model and the performance parameter of  IS series cen-

    trifugal pump.

    ISG Series centrifugal pumps are designed for such as hot water pump and corrosion resi-

    stance pump and oil pump for  the different temperatures and liquids. The pump has good

    performance of reliable operation and high effeciency and little noise etc.

ISG series vertical pipeline cooling water centrifugal pump

  1,Compact structure,horizontal structure ,beautiful appearance and less area of occupied land,

      which comparing with the ordinary ones is reduced by 30%;

  2,Stable running ,low noise,high concentricity of assembly.By the straight joint between motor

     and the pump.the moddle structure is made simplified ,thus enhancing the running  stability ,

     making the impeller of a good balance of moving -resting ,resulting in no vibration during run-

     ning and improving the environment of usage .

  3, No leakage .a mechanical seal of antisepticcaarbide alloy is ued for the shaft sealing so as to

     let rid of the serious leakage of the fillings of centrifugal pumps and ensure the operating place  

     clean and neat ,

 4,Convenient service .


ISG series vertical pipeline cooling water centrifugal pump

 1.ISG series vertical pipeline centrifugal pump is used to transport the water and other liquid

     similar to the water in physical and chemical characteristic. It is widely used for the drainage

     in industry and city, booster and water supply for high-building, irrigation in garden, booster

     in fire fighting, transporting from along distance, water circulation in circultion system etc.

     Working Temperature<80oC.

 2. IRG series vertical hot water pump is suitable in metallurgy, chemical industry, textile, timber

     processing, paper making and booster and circulating for high temperature and hot water in

     hotel.

     Working temperature <240C.

 3. IHG series vertical pipeline chemical pump transports the liquid which is corrosive an without

     solidgrain and similar to water in viscosity. It is suitable in petroleum, chemical industry,metal-

     lurgy, electric power, paper making, food an   pharmacy and synthetic fibre etc.

 4. IHG series stainless steel chemicalcentrifugal pump with explosion-proof is suitable to trans-

     port the flammable  chemical liquid.


Q:What are the differences between the sewage pump and the clean water pump?
2. in order to prevent the wound, water pump impeller design is more simple but not ring pump, equipped with tips, cloth and other debris can be crushed after the pump, and the impeller water pump is relatively complex, but the efficiency will be significantly higher than the former.Why can't the sewage water pump and impeller: because features of key design, resulting in water pump for sewage situation is likely to occur, blocking, winding, wear and corrosion occurs, resulting in damage to pump or scrapped, so water pump can not be used for sewage.
Q:A residential building with a floor height of 11 stories and a roof height of 33 meters. The height of the water tank is 37.7 meters. The basement is -3.3 meters, only set fire hydrant, fire pump only consider the indoor fire water, fire flow should be 10l/s. Now select a fire pump, concrete should be much traffic, big head, flow determine how? How to determine the head, I hope to say some more detailed, thank you, and there is to explain this question, why is the fire pump lift 120?. Thank you
Such as a large pressure of about 10m or about 0.1MPa} because the most unfavorable point fire hydrant requires more than 0.07MPa (7m) and 0.5MPa (50m) is not greater than the pressure, so unless the pump is located in the 50m Valley is still lower than the garage, or add to the valve (or the use of fire hydrant decompression) otherwise, it is 120m lift pump
Q:How to install, operate and maintain the pipeline booster pump?
The motor coil is provided with a safety protector, and when the pump is out of order or the water is not pumped, the motor can automatically break down when the temperature of the motor exceeds the prescribed value, and the motor can automatically resume operation after the temperature rise of the motor is decreased. The booster pump motor is a capacitor running type motor. When the pump leaves the factory, the rotation direction has been adjusted. If you need to replace the capacitor or re connect, press the arrow direction on the pump body to mark the connection. To ensure safety, use the three - core safety socket with ground wire.
Q:5 floor water pressure is too low, what kind of water pump is better?
Pipe blockage, leaks, or throttling devices are not opened. This can be tested on a pipe with a pressure gauge;Water pump is equipped with power source, power or speed does not match, check the pump and power end nameplate, power end of the pump power is generally 1.1.5 times;
Q:What's the meaning of the pump head in the water pump, please advise, thank you
The pump head of the centrifugal pump refers to the shell that contains the impeller and impeller, and also includes the shaft part that drives the impeller. It can be used as the part of the motor and shaft coupling and the base.
Q:What's the difference between non negative pressure and variable frequency water pump?
When peak water is used, the fluctuation of water pressure will be the same for customers! Because the key to the fluctuation of hydraulic pressure is the flow rate of the pump and the lift of the pump. As long as the flow of the selected pump is large enough, the tank is large enough, the lift head is suitable, and the pressure fluctuation is relatively small. And the selection of non negative pressure and frequency conversion pump group is not directly related. If the municipal tap water pressure and water sufficient (large enough diameter), the use of non negative pressure is better. If the municipal tap water pressure and water shortage, you can only use the frequency converter pump + water tank, no negative pressure can not be used.
Q:Brief description of centrifugal pump on / off operation
(3) check whether the turning rotor is easy and flexible, check the pump body is clang or friction sound.(4) the protective cover is installed, and the shield contact.(5) clean the pump frame and do a good job of sanitation.(6) open the inlet valve, make the liquid full of pump body, open the vent valve, clean the air and close it. If the hot oil pump, it is not allowed to open the air valve exhaust, to prevent hot oil channeling spontaneous combustion, if there is a dedicated vent pipes and tanks, you can vent the pipe line air and cold oil.(7) the hot oil pump should be preheated slowly before starting. Especially in winter, the pump body and the pipe should be preheated at the same time, so that the temperature difference between the pump body and the conveying medium is below 50 centigrade.(8) the oil must be sufficiently dehydrated before being introduced into the oil pump.
Q:Water pump does not produce water, what are the reasons?
6. is the motor running in correct directions?.7. pump body failure, such as sliding off the leaves or too much gap between the mouth ring.
Q:Must the water pump in the tank be all soaked in water?
Of course, if the motor is overheated, it will burn, and the temperature of the water will drop down.
Q:Why is the sewage pump device coupler?
Automatic coupling installation of sewage pump is a sewage pump with automatic coupler and a guide rod guide chain fixed installation, convenient maintenance, manual maintenance can be directly hung up by the pump coupling device, ordinary sewage pump is generally Mobile

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Hot Searches

Related keywords