• High Medium Voltage Drive 6KV 1400KW RMVC4000-A060/1800 VFD System 1
  • High Medium Voltage Drive 6KV 1400KW RMVC4000-A060/1800 VFD System 2
High Medium Voltage Drive 6KV 1400KW RMVC4000-A060/1800 VFD

High Medium Voltage Drive 6KV 1400KW RMVC4000-A060/1800 VFD

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
100000 unit/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Energy-saving Solutions for Enterprise
1
Program Overview
Saving energy achieves 10% -70%
The enterprises do not need to pay for expense of equipment manufacture and installation.
Enterprises only need to pay the saving electricity expense to our company according to the actual quantity of energy saving after the equipments put into operation.
According thousands of the projects’ implementation experiences, such projects recover the investments in three or four years. (Equipment service life is 15 years)
Our company will no longer charge the saving electricity expense after recovering the investment.

The significance of the program:
1
)、Concentrate on solving problems of energy conservation, make enterprises’ energy-saving work reach new level and take their social responsibility
2
)、Avoid the enterprises reactive power fine of low power factor caused by electric energy using (according to Ministry of Electric Power and Water Resources, State Price Control Bureau establish the " measures of power factor adjustment expense ").
3
)、Avoid the high-energy consumption enterprises are implemented differential prices because of the changes of national power regulation.
4
)、For the standard-conforming large-scale (saved energy equal 10 thousand tons standard coal or more) energy-saving technological transformation projects, China will reward the enterprises for energy saving which based on the "Financial Incentives Interim Measure for Energy-saving Technological Transformations" established by Ministry of Finance, the National Development and Reform Commission.( Amount of 200 yuan / ton of standard coal).
5
)、Equipments recovery period is generally 3-4 years, each period payment equal to the amount of current energy-saving benefits, and equipments service life are 15 years, so enterprises will gain huge energy-saving benefits.


2
Implementation Process
Energy Audit
Energy Saving Program Design
Construction Design
Equipments Manufacture
Construction and installation
Maintenance and Repair
Energy Monitoring and Efficiency Insurance
Recovery of Program Investment


3
Program Features
High energy-saving efficiency
The project saving rate is generally 10% -30%, highest is up to 70%.
Clients Zero Investment
All works of design, audit, manufacturing, construction, monitoring are handled by RXPE, clients does not require investment.
Energy-saving Guarantee
RXPE promises the amount of energy saving, ensuring that clients’ cost reduction immediately.
Short Investment Recovery Period
The investment recovery period is short, average period is 3-4 years.
Low Risk
Customers do not input large sums of money also can enjoy professional energy-saving products, technologies and services, and the investment risk is very low.
Improvement of Cash Flow
Customers with the support of RXPE approve energy-saving program to improve cash flow, invest the limited funds into other priority investment areas.
Enhance competitiveness through implementing energy conservation, improving energy-saving efficiency, reducing energy costs and enhancing the quality of environment, establish green corporate image and enhance market competiveness.

Q:How to choose a Siemens inverter for a 5.5KW three-phase motor (2 pole)?
Beijing easy to create a website with Siemens inverter selection manual! You can log on online! Or contact them directly, they will give you professional answers!
Q:What is the motor series parameter setting of the inverter? If it is with the spindle,
Ordinary inverter standard drive is a 4-pole motor, the greater the number of poles of the motor, the greater the rated current, the motor pole number is the frequency converter when the self-learning automatically set, in the vector control must be self-learning
Q:What is the working principle of high voltage electrodes and frequency converters?
High-voltage inverter is the input power supply voltage above 3KV high-power inverter, the main voltage levels are 3000V, 3300V, 6000V, 6600V, 10000V and other voltage levels of high-voltage high-power inverter High voltage inverter from high - low - high; low - high; high - high points.
Q:How to learn the inverter debugging and design parameters
You can find the basic inverter manual, see a few times to try, under normal circumstances, the inverter on the use of manual functions such as research to understand that most of the applications are no problem.
Q:Do not the laptop directly connected to the power adapter?
2, due to the different configuration of the notebook, its power consumption also has a variety of specifications. Common for more than 60W, the configuration of some of the 90W, and the game adapter power in more than 120W, such as dual GTX1080 card crossfire Blue Star prototype, power consumption in more than 400W, the use of two 320W power adapter for its power supply;
Q:Is the laptop power adapter high temperature normal? Is there anything else?
In fact, I am also facing such a problem, but I have solved: First: you put the battery together, together with the power adapter, 1 hour after you will feel very hot, it is estimated that you say this. Although your battery is full of electricity. Second: the battery removed, and then use the power adapter, 1 hour after you will feel the general heat, much better than the first case. If you follow the above operation is what I said the same situation, it shows that your power adapter is no problem, because I specifically looking for professional after-sales such a problem, and later also detected the battery, are normal, so if you want is not very Hot, you can remove the battery.
Q:380V motor addition to the inverter, but also how to change its speed?
1. Change the number of pole pairs of the motor. (Multi-pole motor use) 2. Use the frequency converter to change the frequency
Q:Three-phase motor, quadrupole asynchronous motor to 15rpm, the inverter output how many volt voltage? The 4 V
The voltage is basically the same, the inverter changes the frequency of the power supply, not the voltage.
Q:What are the AC motor speed control methods? What are the characteristics of each
1, the frequency converter: smooth, according to the need to adjust the speed, is the future direction of the development of AC motor; (FM) 2, star, triangular connection conversion, generally in the larger motor start star start, triangular operation, Starting current. (Magnetic pole pairs) 3, there is a two-speed, three-speed motor, an increase of the winding, the main change in the stator winding connection to change the speed. (Change the number of pole pairs) The speed of change has two factors: magnetic pole logarithm, frequency
Q:What are the differences and links between the soft starters and the frequency converters, and their respective principles and uses?
Soft starters and frequency converters are two completely different uses of the product. The frequency converter is used for the need for speed control where the output not only changes the voltage but also changes the frequency; the soft starter is actually a voltage regulator for the motor to start when the output only changes the voltage and does not change the frequency. The frequency converter has all the soft starter functions, but its price is much more expensive than the soft starter, the structure is much more complex. Soft starter (soft starter) is a set of motor soft start, soft stop, light load energy saving and a variety of protection functions in one of the new motor control device, known as the Soft Starter abroad. The softener uses a three-phase anti-parallel thyristor as a voltage regulator, which connects it between the power supply and the motor stator. This circuit, such as three-phase full-bridge rectifier circuit. When using the soft starter to start the motor, the output voltage of the thyristor gradually increases, the motor gradually accelerates until the thyristor is fully conductive, the motor works at the mechanical characteristics of the rated voltage, smooth start, reduce the starting current and avoid starting the overcurrent trip. When the motor reaches the rated speed, the start-up process ends, the soft starter automatically uses the bypass contactor to replace the completed thyristor, providing the rated voltage for the normal operation of the motor to reduce the heat loss of the thyristor and prolong the service life of the soft starter , To improve its efficiency, but also to avoid the harmonic pollution to the grid. Soft starter also provides soft stop function, soft stop and soft start the process of reverse, the voltage gradually reduced, the number of revolutions gradually reduced to zero, to avoid free-wheeling caused by the impact of torque. How the frequency converter works

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Related keywords