Heat Insulation Pump APPLICATION

*It applies to delivering medium not include solid particles and the temperature not higher than 300°C.

*It also applies to the site with heat insulated requirement in the process technology and outdoors installation at every cold area.

*External gear pump,the tooth form is composite formed by arc and sine curve.Keep warm and cooling the transferred medium and pump.

*Visocity larger than 1500cst,speed should be reduced.

Product namebitumen gear oil heat insulation pump
Model numberHeat Insulation Pump
TypeRotay pump,gear pump, Heat Insulation Pump
Application ScopePerformance as transfer pump or booster pump in oil delivery system,and fuel pump for delivery,pressurization and injection in fuel supply system. As hydraulic pump supplying hydraulic power in hydraulic system.
Material

1.HT200;
2.ZG230-450
3.1Cr18Ni9Ti,OCr18Ni12Mo2Ti

Capacity1.1~570m³/h
Viscosity5×10-6~1.5×10-3m2/S(5-1500cSt)
TemperatureBelow 300°C
CharcteristicDouble circular teeth shape,which makes the gears less wear on gear surface,stable revolution,low noise,long service life and high efficiency,due to no sliding on the  teeth during gear falling in.
Axle-end sealMechanical seal and packing seal
ShipmentBy sea or air
Delivery time25-45 days according to order quantity
MOQ1 pcs
PackageExport standard wooden palet or user-defined
Payment methodsTT, L/C, Western Union, Escrow

Heat Insulation Pump PRODUCT ADVANTAGES


* Steady output flow and pressure. Steady delivery without pulsation, little vibration and noise
* Working temperature can reach 300°C
* Out standing self-priming ability
* Little wear and long operation life
* Suit to transfer heavy oil,asphalt,resin,detergent and glue.

Our Heat Insulation Pump has approved GL,ABS,BV,DNV,3C,CE,ISO-9001 2000,GJ9001A-2001 etc certificate

Q:Centrifugal pumps for normal operation, is it reasonable to install valves on their inlet lines? Why?
Unreasonable, easy to produce throttling loss, pressure loss, pressure reduction, easy to cause cavitation
Q:What is the difference between the ground pump and the pump in the commercial concrete?
Move back and forth; pour concrete into a certain area. After the filling is finished, the whole pump truck can be moved to another position quickly
Q:Why adjust the centrifugal pump outlet valve can adjust the flow? What are the advantages and disadvantages of this method? Is there any other way to regulate the flow of the pump?
The use of frequency converter to adjust the speed of the motor can also adjust the flow, the advantage is to save electricity.
Q:The main factors affecting the performance of centrifugal pumps
Revolutions required to have. It has the following meanings: 1, similar to the geometry of centrifugal pump, everywhere efficiency at the top of the similar condition; centrifugal pump 2, than the number of different, its geometry must be different than the number; the same pump, its shape is similar, but does not rule out the shape similar situation. The following factors are related to specific speed. The specific speed of centrifugal pump has nothing to do with the nature of the conveying fluid, but has a close relationship with the shape of the impeller and the performance curve of the pump. The pump with high specific speed corresponds to the highest efficiency when the flow rate is large and the head is small
Q:What are the constant pressure pumps?
Chlorine booster pumpThe pressure range of chlorine booster pump is large, and different pump can be used to obtain different pressure area. The input air pressure is adjusted and the output pressure is adjusted accordingly. High pressure can be reached, gas 90Mpa. Wide range of flow, for all types of pumps only 0.1Kg pressure can work smoothly, at this time to obtain the minimum flow, adjust the intake volume can be obtained after a different flow. Easy to control, from simple manual control to fully automatic control, can meet the requirements. Automatic restart, regardless of what causes the pressure drop in the pressure loop, will automatically restart to supplement leakage pressure and maintain constant loop pressure. Safe operation, gas driven, no arc and spark can be used in dangerous situations.
Q:5 floor water pressure is too low, what kind of water pump is better?
Installed pump flow, lift did not meet the requirements, this will need to re type selection, calculation;
Q:I want to know the concrete under 60 type pump performance, it is mainly the pump long spiral bored piles, such as the diameter of the pump, transportation distance, pumping height and so on, thank you!
HBT60.13.90S performance parametersParameter name unit HBT60.13.90SMaximum theoretical concrete conveying capacity m3/h 69/43Maximum pump outlet pressure Mpa 13/7
Q:If you use an ordinary 15W submersible pump, put it in the tank, if the leakage, the fish will hang it?
What will happen then? The aquarium glass is an insulator. The water in the fish tank has the same potential as the live wire, and the fish is like a bird standing on the fire line. No electricity flows through their bodies, so they won't get electrocuted. But if you put your hands into the water, you will get an electric shock, because the line voltage through the water, then your body and the earth to form a loop, current flowing through your body you will get (of course, if you stand on the insulator does not get an electric shock)
Q:How long does the fine stone pump need maintenance? What should I pay attention to?
Check the line from the relief valve to the cylinder inlet to ensure that there is no external drainage or deformation due to impact and wear and that the connections are complete and fully tightened. - replace any damaged pipe immediately. - change the original settings strictly: all adjustments and calibrations can only be done by professionals. - no fucks hydraulic components, otherwise manufacturers on product warranties and liability shall not be responsible for. A warning because the hydraulic oil can reach very high temperature, there is the danger of burns, so open pipe fittings should take appropriate protective measures. Any replacement parts must conform to the level specified by the manufacturer. 8.2 check lubrication grease pump in oil at any time to ensure adequate and clean the lubrication pipeline joints without overflow phenomenon. Check the lubrication of the running parts at any time, and find the parts which lack oil, and check them immediately to prevent accidents. - check that the centralized lubrication system is effective daily. When the grease pump is empty, the grease added is often not easy to pump out because of the bubble. In this case, open the outlet of the pump, run the grease pump until the grease is re flowing, and then connect the pipe
Q:How to distinguish the flow and displacement in the hydraulic pump? What's the difference between the two?
The unit of displacement is the milliliter. How many milliliters does the pump rotate per circle? The displacement is the pump, the individual,The unit of flow is generally a liter, a figure added to the displacement of the pump over a period of time,

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Hot Searches

Related keywords