• Frequency Drive 7.5kw 380v 3 Phase Inverter System 1
  • Frequency Drive 7.5kw 380v 3 Phase Inverter System 2
Frequency Drive 7.5kw 380v 3 Phase Inverter

Frequency Drive 7.5kw 380v 3 Phase Inverter

Ref Price:
get latest price
Loading Port:
Qingdao
Payment Terms:
TT OR LC
Min Order Qty:
1 unit
Supply Capability:
3000 unit/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

7.5kw 380v 3 phase frequency inverter for air compressor  

 

Reckoned to be the quality-oriented organization, we ensure that clients are served efficiently most appropriate manner. Clients appreciate our range for their quality and easy availability, besides the reasonable prices. Suggestions of clients are always welcomed and we make changes accordingly if required. We ensure that queries of clients are solved in minimum time-frame with appropriate solutions.

 



Introduction of SVF-G7 Series High-performance Vector General-purpose Frequency Inverter

 

1. Voltage class: 380V


2. Range of power: 0.4KW~450KW


3. Stable and reliable Control Mode


(1) VF control: Multiple curve could been chosen, Linear V/F curve, 2.0 times power drop torque V/F curve, custom V/F percentage(can realize manual energy saving control), multipoint VF curve. This apply to the situation that one frequency inverter drives multiple motors, such as fan, water pump, engraving machine, injection molding machine etc.


(2) Open-loop vector control: Steady speed with high precision, wide range of speed governing, as the speed ratio is 1:200 and 180% rated torque could be output in 0.5Hz. Good dynamic performance.

Open-loop vector is suitable for high-Performance universal occasions such as machine tools, centrifuges, cranes and handling equipment, rolling mill and other loads.



(3) Torque control: Fast torque response,<20ms, precision torque: <5%, applied to winding, drawing and other occasions.

 

 

Reckoned to be the quality-oriented organization, we ensure that clients are served efficiently most appropriate manner. Clients appreciate our range for their quality and easy availability, besides the reasonable prices. Suggestions of clients are always welcomed and we make changes accordingly if required. We ensure that queries of clients are solved in minimum time-frame with appropriate solutions.



.JPG



Trade terms

 

a. Delivery term

We will delivery for you after you done the full payment within 3 to 15 working days.

b. Payment

For small order by air or by express, it is 100% T/T in advance.

For large order by ocean, 30% deposit of the order value should be paid, 70% of the balance payment should be done before delivery.

c. Packing                            

Unless otherwise stated in the offer, the prices include packing in accordance with CHINSC’S customary standard of packing.


Applicable fields

Widely used in various fields such as metallurgy, petroleum, chemical industry, textile, power, construction material, coal, pharmacy food, paper making, plastic, printing & dying, lifting, cable making, washing, water supply, heat & ventilation, sewage treatment and son on. In addition the products can also be applicable to draw benches, mixers, extruders, winding machines, compressors, fans, pumps, grinding machines, belt conveyors, hoists and centrifuges.


Welcome your inquiry!

 

 

Looking forward to cooperating with you!


Q:Inverter problem
A: The inverter output 4 ~ 20mA (0 ~ 20mA), the analog signal can be directly connected to the measuring instrument, the daily design, installation, application are so, as long as the selection is correct, there will be no problem.
Q:The inverter control power is also the same, the pole is not the same as the motor 6 or 4 pole can be used?
Can be used, their rated current is not the same, the need to use the inverter over-current overload protection and other parameters for the corresponding changes.
Q:There is no inverter comes with simple PLC programming function
Inverters are generally digital input, and analog input, a digital output, etc., can also be controlled by means of communication. Digital input can be used as a positive and negative and reset the alarm, the analog input can be given as a speed, and how to use the inverter to see the specific model. Take the Siemens inverter, MicroMaster420,567 terminal 3 digital input, 8 for the 24V, 9 for the 0V, you can usually open the point on the 8th 24V back to 567, as a digital input, you can also directly into the switching power supply Of the 24V, but the switch power supply 0V and 9 terminals connected to the potential, or the inverter may not be able to identify the outside world 24V. (DP communication, USS communication, etc.), with the terminal input on the P0700 = 1, the user can set the command source, the panel can be input, 2, P0701 to P0703 corresponding to the three digital functions: parameters set to 1 forward, 2 for the reverse ... ... a lot of features and control methods, see the corresponding product manual like
Q:2 pole 0.75 kW motor can increase the speed through the inverter?
if the 4-pole motor to rise to 2-pole motor frequency, The frequency of the motor rises to about 100 Hz, which is easy to implement for the frequency converter.
Q:What is the difference between the collector and the emitter mode?
The emitter is very high, the base is mixed and the collector is the lowest
Q:What is the output voltage of the laptop power adapter?
Laptop power adapter output voltage, different brands may be different. Adapter output voltage is not a unified standard, different models are not the same notebook. The output voltage between 12V to 20V, 19V, 20V more.
Q:My inverter is the era TVF8000 series, the motor is 15KW6 pole motor, has been used for 3 years.
For your situation about the summary of recommendations: First, check whether the motor overload and whether the leakage exceeded, Second, check and clean the inverter fan, if the room temperature is high, add the external fan to the inverter cooling Third, if none of the above, then please check the inverter module is burned, replace the module Fourth, if the inverter is no problem, then the motor and load the problem, if the motor problems are not resolved, then only re-select the inverter, please select the time to increase the margin
Q:Abb inverter s510 with water circulation pump why the motor fever. The motor is 2 pole
Check the inverter operating power factor, straight up the motor to see if it is overheating
Q:Delta VFD-F frequency converter how to adjust the number of poles
P148 look, this is to correspond to the number of poles of the motor, not to adjust the number of poles of the motor
Q:What parts of the inverter composition
Simply put, the inverter is mainly composed of rectifier (AC variable DC), filter, inverter (DC variable AC), brake unit, drive unit, detection unit micro-processing unit

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Hot Searches

Related keywords