• DN220 Spectacle Plate for IHI Concrete Pump System 1
  • DN220 Spectacle Plate for IHI Concrete Pump System 2
  • DN220 Spectacle Plate for IHI Concrete Pump System 3
DN220 Spectacle Plate for IHI Concrete Pump

DN220 Spectacle Plate for IHI Concrete Pump

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 pc
Supply Capability:
1000 pc/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing


Product Description:

Product Name: DN220 Spectacle Plate for IHI Concrete Pump

1.        Specification

 

Size

DN205DN220

Material

tungsten carbide, Q235B steel, Vautid-150 electrode imported from Germany

Lifetime

30,000-80,000cbm

Carbide HRA

> 86

Electrode HRC

> 63

Type

hardfaced, tungsten carbide and 7 shape tungsten carbide

2.        Application

Spare parts for mud pump, shotcrete,trailer and truck mounted concrete pump

         3.  Package

Plastic bag and carton box, also according to your requirements

FAQ:

Q1: Why buy Materials & Equipment from OKorder.com?

A1: All products have its ISO certifications, adheres to the highest standards and a commitment to supply chain safety and customer satisfaction.

Q2: How do we guarantee the quality of our products?

A2: We have established an advanced quality management system which conducts strict quality tests at every step, from raw materials to the final product. At the same time, we provide extensive follow-up service assurances as required.

Q3: How soon can we receive the product after purchase?

A3: Within three days of placing an order, we will begin production. The specific shipping date is dependent upon international and government factors, but is typically 10 to 30 workdays.

Q4: If we can produce DN220 Spectacle Plate for IHI Concrete Pump according to customers request?

A4: Yes, we can produce DN220 Spectacle Plate for IHI Concrete Pump according to the difference country situations to make it suitable to the market and customers. We have very professional technical team to make the design.

Q5: How to make a quick resolution for after service?

A5: We have overseas branches all-around of world, If needed, the seller shall dispatch 2 engineers to the buyer's site for supervision of training. The buyer shall make available of necessary facilities &skilled personnel at site for training.

 

Images: 

 

 

DN220 Spectacle Plate for IHI Concrete PumpDN220 Spectacle Plate for IHI Concrete Pump

 

DN220 Spectacle Plate for IHI Concrete PumpDN220 Spectacle Plate for IHI Concrete Pump

 

DN220 Spectacle Plate for IHI Concrete PumpDN220 Spectacle Plate for IHI Concrete Pump

 

 



 


 


Q:A residential building with a floor height of 11 stories and a roof height of 33 meters. The height of the water tank is 37.7 meters. The basement is -3.3 meters, only set fire hydrant, fire pump only consider the indoor fire water, fire flow should be 10l/s. Now select a fire pump, concrete should be much traffic, big head, flow determine how? How to determine the head, I hope to say some more detailed, thank you, and there is to explain this question, why is the fire pump lift 120?. Thank you
According to the water quantity form fire flow water supply system fire safety in high-rise building fire hydrant pump lift is 10L/s, accurate algorithm is to say after a simple calculation with each indoor hydrant flow is two 5L/s bolt so to get the most unfavorable point for the calculation unit to calculate the minimum requirements, with the most unfavorable point suppository pressure specifications 0.07MPa, partial loss of the most unfavorable line and the line (according to the equivalent length) and loss (according to the material resistance coefficient), and finally the pump head loss of gravity difference. But we just calculate the construction elevation difference multiplied by 110% to 120% to determine the head {there is a need to know is: conversion head (m), (kg) and MPa kg 1MPa=10 kg = 100m is the vertical water column on unit area pressure conversion
Q:How many concrete pump tube diameter
Different pipe diameter is different, most of the 125, there are 150. Now we have the smallest pump on the market, with a pipe diameter of 100.
Q:Why adjust the centrifugal pump outlet valve can adjust the flow? What are the advantages and disadvantages of this method? Is there any other way to regulate the flow of the pump?
This method can be used to regulate flow. The advantage is that it is simple and easy to use and the disadvantage is that the throttle consumes energy
Q:Fire pump and shower pump flow head selection, high resolution.
Selection of flow head of fire pump and spray pump:1, the volume is greater than 5000 is less than 10000, the minimum water consumption of indoor fire hydrant is 10L/s
Q:What is the displacement of the pump? Flow? What is the volume efficiency and mechanical efficiency of the pump?
Mechanical efficiency: the ratio of theoretical torque to actual torque of the pump.
Q:What is the principle of a turbopump?
Turbine [turbine] is a machine that converts the energy contained in a fluid medium into mechanical work, also called a turbine. Turbine is the transliteration of English turbine, derived from the Latin word "turbo", meaning "rotating object".
Q:Harm of air pump and pump
If the liquid is not full, this situation is generally the suction pipe or pump shell leakage, then easy to cause cavitationHit the pump for centrifugal pumps, centrifugal pump is recommended to start closed, the discharge valve closed, starting is in the state of pump
Q:The difference between diaphragm pumps, vacuum pumps and centrifugal pumps
The diaphragm works by changing the size of the diaphragm. When the cup is covered with an eraser and the edge is airtight, then pressing the rubber or pulling the rubber outward will make the pressure in the cup increase or decrease. Use this principle, in the pressure of an hour from a hole suction medium, when the pressure is large, from another hole extrusion medium, so as to achieve the purpose of conveying.
Q:What are the ways of hydraulic pumps?
Hydraulic pump is a power component of hydraulic system. It is driven by an engine or an electric motor. It draws oil from the hydraulic tank to form a component of the pressure oil which is sent to the actuating element.
Q:What are the advantages and disadvantages of the pump control system and valve control system in the hydraulic system? How to choose in the project?
Large pump control valve controlled energy consumption at least 30% reason is that there are serious throttling loss of a throttle valve control system of severe fever but simple structure and low cost which is why now valve control system still occupy the main market reasons.Pump control system with complicated structure especially when serious nonlinear control unsymmetrical cylinder control effect is not ideal, but the biggest advantage is energy-saving and low fever America professor Monika points out that using the pump control system of hydraulic excavator energy efficiency compared with the valve control system can be improved by over 46% but costs are high. But in control, the three pump invented by Professor Quan LONG of China is a good solution. LZ can find the invention patent or find his paper on sage. It seems that there are three or four SCI about this pump

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Related keywords