• Cable Duct System 1
Cable Duct

Cable Duct

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT or LC
Min Order Qty:
500 Meters m
Supply Capability:
300 Tons per Month m/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

1.The certification:

1).CE of Europe: EN 60947-1:l2007 (CLAUSE 7.3,8.4), class of fire proofing, little smoke and halogen, no firing encounter fire, good in fireproofing and insulatio

2).Wiring Duct RoHS

 

2.Material:Made from hard PVC, low halogen material, rigidity PVC, environment protecting, no pollution, no lead, no venomous matter.

3.Work temperature: -25degree-75degree, 85degree of standing high temperature

4.Struction: Made up of duct bottom and lid

5.Feature: be made of bottom and cover, there are thread holes in the bottom.

6.Length: 2.5m

7.Color: All colors are available.

8.Application: Used in stage, electric apparatus, air conditioning or indoors.

9.Using method: fix the bottom first, put thread in it, then cover

 

10.Characteristic:

1,combined strongly, no taking off, smoothness of  the surface, no hurting hands and mangling the thread nearby.

2,hard to break, color changing, distortion under the temperature of 70 degree.

3,low thread hole, easy combination, take down simply, easy wiring,

4,no thread hole and airproof, dust protecting, mouse protecting, suit to construction and factory.

Q:Now home improvement of the electrician is not standardized. Just found his 4-point line into the seven. But there are four sub-line into the six for the majority, there is a relationship? What should I do? In addition, my home air conditioning line is used in 4 square lines, zero fire for the 4 square line, the ground is 1.5 square is also penetrated 4 minutes, there is a relationship? What should I do? Question added: see those who are wearing the line, I really want to cry, how do? More
Look at the distance by 1.5 square feet is enough, but consider the impact of all aspects of the best .5 square feet.
Q:How the concrete pillars are embedded in the tube and the bottom box
first of all audio and video lines to EVD and LCD TV ("video 1") connected; turn left | turn right Moreover, the set-top box and LCD TV (HDMI1) With the high-definition multimedia interface cable (HDMI cable) together; turn left turn | turn right the LCD power supply, the EVD and set-top box power are open; according to the signal Source selection, if you want to see EVD program, put the signal source to switch to "video 1", if it is to see the set-top box program, put the signal switch to "HDMI1" so that put EVD and set-top boxes are also connected to the TV
Q:Is the toilet wire walk on the ground? Are there any hidden dangers?
Cable split screen refers to the cable in a group (a bunch) insulated wire core first shield (which is sub-shield, referred to as: split screen), and then do a number of sub-shielded multi-bundle re-combination (twisted System) together, and then do a whole shield, which is the total shielding, referred to as: the total screen
Q:Wall after opening the wire tube after the request outside the surface of the tube is not less than 15mm, I would like to ask: from the structure of not less than 15mm? Or from the plaster surface is not less than 15mm? More
The desktop board becomes the motherboard, the most critical or interface and cooling aspects, such as desktop board baffle at a row of I / O interface, all to give up, and then all re-wiring with a cord to connect, the other Is the other slots, and equipment reduction, such as PCI slots and equipment, and the most critical PCI_E and PCI_E graphics card reduction, if you want to install high-end graphics card, power and heat, but a lot of problems ~ there are cooling, (Speaking of desktop motherboards because desktop motherboard support CPU performance can go beyond the most advanced books now several times the cost of the book, of course, the performance improved so much, followed by the rapid heat Increase, you have to solve the problem of heat, and certainly less is the water cooling, how do you set up this water cooling device, but a big problem, coupled with the graphics card GPU, motherboard NB and SB heat, you need to set up a very Large water cooling system, and some to study. But you are very innovative spirit ah ~, refueling it, I hope you can study out, no matter who, should be a very good thing, IT industry and even a few steps in a few steps ~
Q:Do not know how to thread, where to start, where the end of the installation process is what, please master guiding. Thank you more
Digital TV set-top box audio and video cable should be properly connected to the TV's audio and video input jack, otherwise the TV screen will appear blue or black screen the user will not open or open the wrong video signal When viewing a digital TV, switch the TV to an accurate AV channel Check the TV input source to switch to the corresponding audio and video interface (according to the different brands of TV according to AV or AV AV AV3 or TV, video selection signal input, source input selection, part of the menu pull down the TV need to select to the corresponding AV input and determine the selection) User Receiver Signal level is too low or no signal In the case of carrier-to-noise ratio and bit error rate are normal, the signal input level in the range of 45-75dB, set-top box can receive digital TV programs
Q:How is the embedded box, weak box and wire tube embedded in the shear wall? Thank you for pointing
Cut the wall within the junction box, weak box and the tube of the embedded method: put the line after the release of the box, such as switch requirements from the ground 130CM, 15-20CM from the door, you can put the line to accurately install. There are fixed when the box to be tied to the steel, where the special attention to the box must be tied to the positive, to prevent the template when you turn the box, of course, the box to put sawdust, it is best to wet, And the more the better, so when you find the box is easier. Sometimes the template and your box get together far away, the concrete is easy to cover your inside the box, you'd better just put the template, not playing the concrete when the brush is on the box with the template on the upper layer of red paint , So when looking for a place to open a red paint on it.
Q:In the decoration of the circuit with which the same good? Which is the same as the general said to buy the same line? In the decoration to electricity with what the pros and cons? More
the first cable signal cable (white) access to the set-top box rear panel signal input;
Q:Home improvement water and electricity wiring, wire tube is a strong power, weak points to buy different colors?
Both sides of the amount of equal length, draw diagonal and then cut, brush as small as possible.
Q:If the electric tube with a piece of brick to go up the building, that wall to 300MM directly after the next box riser or there are other ways? 300 or more direct standpipe, then the wall can not build up the tube how to stand up, how fixed? Is the first box or the first tube, or a next? What's under the roof? Is the ceiling embedded in the roof or hoisting (lighting, sockets, integrated wiring)? How many millimeters are lifted under the roof? The above questions according to your construction experience to answer, do not control the drawings, the more detailed the better answer. Questions added: the above problems according to your construction experience to answer, do not copy from the Internet, because the Internet is very general do not understand. I am an electric line buried in the layman. More
May be the root of your graphics card cooling, if the hot weather you can open the left half of the chassis to run the computer, so the cooling effect is very good
Q:1. New to buy a house, there is a root threading machine developers did not wear a cable, from the weak box to the living room box, is due to need to be in this 1 tube to wear two cable, easy to wear? 2. From the weak box to the living room line box length of 8 meters, the cable about how long? Would you please understand someone? More
It is recommended to use a low-smoke halogen-free screw. Reason: wire and cable extrusion equipment is the main component of the screw, it is related to the scope of the extruder and production efficiency, in order to meet the needs of different plastic processing, there are many types of screw. Low smoke halogen-free flame retardant cable material contains high-filled magnesium hydroxide or aluminum hydroxide, so the choice of the screw for the general use of ordinary type screw and its compression ratio can not be too large, generally 1: 1 ~ 1 : 2.5 between the more appropriate. the extrusion process also has an impact on the low-smoke halogen-free cable material out of the important single-purpose toilet to help solve the problem, that is the extruder cooling device, because the low smoke halogen-free material special Sex, in the extrusion process, due to friction and produce large heat, which requires extrusion equipment to have a good cooling device in order to control the process temperature. This is a problem that can not be ignored, if the temperature is too high will make the cable surface has a large pores, the temperature is too low will make the machine's machine current increases, easy to damage the device.
We owned a mature group of 150 workers and set up an integrated quality control system to guarantee zero defect rates. Therefore, we have gained high satisfaction rate from our customers worldwide, with over than 8years experience of export sales, our products are popular in the South of America, South and Middle of Africa, Mid-east zone, Pakistan, India , south and east of Asia and so on.

1. Manufacturer Overview

Location Guangdong,China
Year Established 2008
Annual Output Value Above US$100 Million
Main Markets 20.00% Domestic Market
20.00% Africa
20.00% South America
10.00% Eastern Asia
10.00% Mid East
5.00% South Asia
5.00% Central America
5.00% Eastern Europe
3.00% Southeast Asia
2.00% Western Europe
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port Shenzhen,SHUNDE,GuangZhou
Export Percentage 71% - 80%
No.of Employees in Trade Department 3-5 People
Language Spoken: English, Chinese, Spanish, German, Arabic, Russian
b)Factory Information  
Factory Size: 10,000-30,000 square meters
No. of Production Lines Above 10
Contract Manufacturing OEM Service Offered Design Service Offered
Product Price Range Average

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Hot Searches

Related keywords