This burner is 465KW one.


Introduction:

Innovative product in China--biomass burner. Brand: HUAYUAN

Specification: 58~1395KW  Burner over 1395KW can be modularized.


The III generation biomass burner promoted in July 2014:

1. We use the casting modularized hearth. The boiler core is the only thing to be replaced in the post maintenance of burner. It is cheap and easy to change the modular fittings.

2. Generation III biomass burner adopts hyper heat-resistant casting material, replacing I and II generation material, which makes less cost and more stable performance.

3. The actual capacity of traditional burner is 70%, HUAYUAN marks authentic datas on the nameplates.

4.  HUAYUAN product has hyper-high temperature efficiency burnning tar and other harmful substance totally which will not be attached to the tubes to cause block.

5. The flame colour of HUAYUAN product combustion is white and blue, realizing clean combustion.  

6. Solve the problem that no coking fuel could be used in the traditional burner. More biomass fuel could be applied.

7. One-button control system to set fire, feed bunker, and control temperature automatically.

8. Equipped with dust blower system, which could be cleaned after long-time usage. Different size of reducer adapter could be made according to customers' requirement.

9. Widely applied to high temperature required conditions as coal-fired, natural gas-fired and oil burning boiler reconstruction, as well as industrial drying painting.



Q:I have a 3-zone system. The zone on the first floor only has heat on 1/2 of the first baseboard in the zone. The return pipe at the boiler from that zone is stone cold. I have bled out all the air but the water almost seems blocked in the first zone baseboard.Bad circulator pump? Since the other two zones are fine I'm guess it's not a common part like the expansion tank.Any ideas?
It seems from what you say, that there is a bad air lock in the return pipe that cannot be vented. I suggest that you slightly loosen the connection of the return pipe on the boiler, as this is the only way the air in it can be removed. But be ready for water escaping with the air. Do this with the boiler switched off.
Q:i am looking to buy a home built before 1890 and it MUST remain as is with it's natural gas boiler. how efficent is this system v's using forced air heating. keep in mind this home is 4800 sq ft and is all plaster walls and hardwood floors. i am sure i could help by using the 3 fireplaces but i am still concerned about the boiler having never seen one before.
The economical efficiency of your current boiler depends on its age, current condition and if was sized correctly for your home and current radiators. New gas fired boilers can reach 98.5% A.F.U.E which is comparable to any forced air system. Comparing hydronic heating to forced air as far as comfort the boiler system is typically much more comfortable, especially in older looser homes. Forced air does give you the benefit of sanitizing and cleaning the air,cooling it adding moisture and replenishing oxygen levels. Hope I haven't confused you. Good Luck.
Q:I have an old Weil-McLain oil/hot water furnace system that the repair man said was probably installed in the 40s or 50s. During recent maintenance on it, I was informed that the boiler was leaking internally causing the stack switch to short out and also preventing the burner from firing. The maintenance man also said I'd have to get a new furnace installed. I asked why he just couldn't fix the leak and he replied that in the old days he could just pack it with some asbestos and that would take care of it, but asbestos can't be used any more. I wanted another opinion as to why a leaking boiler necessitates purchasing and installing a whole new furnace and why just the leak can't be repaired. Where is the boiler? I though it was the large cylinder over the furnace, but the maintenance man said that was just the expansion tank. Is it inside the furnace?
OK lets stop here a min. Have you talked to a Heating Company or just the maintenance man? Call a professional HVAC company. Is it a furnace or a boiler? expansion tank.is not in the furnace, It most likely hanging up on the ceiling or connected to the pipes somewhere near the boiler The LEAK is of carbon monoxide and other gases the stuff can kill ya. Boiler is on the floor with pipes connected to it.
Q:I live in a 3bed semi. The boiler is ok but I would like to buy an 'A' rated new type. I do not know where to start, suffice to say that when I went on British gas site they did not give any prices!! I always like value for money....thanks in advance, Lindsey
ultimate to seek the internet for the final bargains. be conscious, make a value assessment for the boiler with each and all of the extras you pick (flues, timers etc) and remember the Vat transport too. sometime to get the commerce provides you with can desire to quote your 'gas secure practices info', and even have a commerce account. Does your gas secure practices engineer no longer comprehend the final places to source your boiler?, i discover the final fee places to purchase one variety is by no ability the main inexpensive for yet another variety. As we ordinarily purchase Valiant boilers, i could no longer say of the right of my head the final bargains for Bosch.
Q:There are 4 boilers if there is a 50 percent chance (who would buy such boilers?) that each boiler works for a year without any breakdown find the probability of realizing at least three boilers in operating condition afterone year.I calculated it like this,at-most one failure= all boilers work OR A fails OR B fails OR C fails OR D fails=(0.5x0.5x0.5x0.5) OR 0.5 OR 0.5 OR 0.5 OR 0.5=(0.0625 OR 0.5) OR 0.5 OR 0.5 OR 0.5........The answer comes out to be 0.8828Is my logic correct?Also anyone knows about matrix method to evaluate reliability? Pls give some link.
no standard formula applies Reliability values (propose Time to Failure = MTF) are provided by way of the producer after a rigorous high quality controls sorting out utilising records for challenge MTF for all equipment with comparable pattern areas/manuf technique.. each and every pump/compressor might have various areas, all of that are component to the MTF try. Warranties often conceal a plenty shorter time than the MTF of the equipment
Q:i just added two baseboard radiators to the basement do i need a stronger circulator pump for the boiler?
As you have drained down the equipment you have air in the equipment. Its combating the water from circulating. What you could desire to do is shop at it and once you get one rad warm, turn it off until yet another heats up and turn that off. you have got the potential to bleed the rads each and every time. besides the incontrovertible fact that it rather is air in the pipes it is the problem. shop at it . it gets greater efficient. To instruct that it rather is the problem, the flow from the boiler would be extremely heat while the boiler turns off. if it is so ,i'm superb.
Q:the pipe outside my house where the excess liquid from the boiler drains out of was spitting out a brown substance so i went upstairs to examine and saw the tray around the boiler was like halfway full of a thick brown gelatinous liquid, i did not touch it but it had the color and look of maple syrup, but of course much less thicker, what is it? whats going on with my boiler?
hmmm.... Is this an oil fired boiler (diesel oil?) or gas? Probably wouldn't hurt to touch the goo, .... it could be a glycol solution used to prevent freezing of the pipes should you loose heat... mixed with a bit of rust in the system and has turned it brown.... sounds like a leak of some kind.... be adventureous and put your finger in the brown goo... rub it... smell it.. it if smells like diesel fuel then you have a fuel leak... if it is slimmy and doesn't have much of a smell other than a stale/rotten smell than possibly glycol leak.... if it is just gooie, wet like water with no real slime it could be just boiler water. It could have a pin hole in the casting and it is just plain old boiler water leaking out... which is usually brown ugly but not gelatinous..... so that is odd... if it is fuel oil... that isn't good but sounds like is not or you would have probably smelled it... and the boiler is located upstairs which is also odd as they are usually located in basement so makes me concerned as to what your realy talking about... but will go for the boiler less any other info about age, make, fuel source etc..that is located up stairs. As for the fluid loss, There is a low water cut off on the system. If the water level drop so far it will shut down the system to protect the boiler = no heat. Regardless sounds like you need to contact boiler people...
Q:I have had the gas repair man in twice he has put a new flow switch in, but still the water goes cold, but it has not done it while he was here it seems to be when i have the heating on, the boiler is not fireing up for the water, can someone please help.
I okorder /
Q:The difference between heat exchange station and boiler room
Said the heat transfer station is like a big overheating, the only difference is that it is very large, they are part of the heating system, and each has a different function.
Q:what is the Boiler in electrics?
These boiler, pre-heater, and super heater items look like cheat notes for an upcoming test. Most likely Lores and Lires are the same person and expect to use his/her cell phone to access these answers during the test.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Hot Searches

Related keywords