Power and lighting transformers, lighting quality will be affected much?
The bulb adopts a luminous two stage tube combined lamp holder, and the calculation process is very complicated. The secondary voltage is different in different combinations. Because it is a direct current ignition, but also consider the efficiency of its rectifier, but the total power is unchanged.
Is the substation separate from the power and illumination transformer?
The power and illumination of the substation are all used on a transformer, which is separated by power and lighting by the station screen of this transformer.
What type of low voltage transformer should be adopted for safety lighting power supply?
Isolated transformer, once 380V or 220V, two voltage, 36V, 24V, 12V, several categories, do not allow the use of autotransformer.
How many A leakage protection switches are used in 5000VA lighting transformers?
AC circuit transformer for lighting lamp is suitable for 50-60Hz, is the power supply with safety shell low-voltage safety lights, can choose 220V or 380V power supply input voltage: 0V, 220V, 380V, 0V, 6.3V, output voltage: 12V, 24V, 36V.
Why is the two side of the lighting transformer grounded?
Today's lighting products, regardless of the control system or the electronic power system itself, contain many semiconductorsComponents such as rectifier diodes, transistors, integrated circuits, LED, and so on. Semiconductor components are susceptible to staticElectrical damage, the two side of the power transformer grounding, help to produce a variety of factors, high pressure, residual static electricityDrain to avoid static electricity on the main circuit, to ensure product life.
What's the function of the lighting transformer?
Illumination transformer: usually refers to the secondary output voltage for the safety voltage 24V - 36V, only for special lighting power supply using voltage converter.
Can the 500 volt lighting transformer be changed into an electric welder?
500 VA transformer should not be used as an electric welding machine, so it is very difficult to reform the system, so it is better to buy a new electric welder
Why the 21 lighting transformer must double winding type safety isolating transformers, prohibited the use of autotransformer.
The self winding transformer is connected by all its windings, and depends on the position of the sliding contacts to change the magnitude of the voltage. Therefore, there is not only a magnetic connection between the primary winding of the autotransformer (the power circuit) and the two winding (the power supply circuit), but also the direct connection of the circuit. It forms a circuit with the earth, so it can not be used as the power source of the safety voltage