Quick Extruding Silane Cross-Linkable PE Compound for 3KV and Below Cable Wire

Ref Price:
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
1000000kgs kg/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Description

Grade 4214Q is sioplas (two steps) silane XLPEcompound for low voltage cable with small cross sectional area, it is composed by silane crosslinkable low density polyethylene (compound A) and silane crosslinkable catalyst (compound B). Compound A is grafted by high activity silane and special PE compound, while compound B adopts the advanced cataly stsystem. The product has outstanding performance and major characteristics are

◆The product is suitable for the extrusion method of squeezing extrusion,half-tubing extrusion and tubing extrusion.

◆Cables made from the product have excellent performance in smooth cable surface, high extrusion speed and production efficiency.

◆Suitable for cable cross-sectional area less than 16mm2.

Standard

Performance test is in accordance with JB/T 10437-2004 standard. After crosslinked in the tepid water, the cable made from the product grade 4214Q can comply with the standard of IEC60502-2004, GB/T12706-2002.

Main Properties & Typical Values

Test items

Test method

Unit

Standard

Typical value

Tensile strength

GB/T1040.3

MPa

≥14.0

19.0

Elongation at break

GB/T1040.3

%

≥350

480

Heat ageing properties (Test temperature 135℃, 168hr)

Maximum tensile strength change

Maximum elongation at break change

GB/T8815

%

%

±20

±20

-12

-5

Heat elongation (200±3)℃x15minx0.2MPa)

Maximum elongation change under load

Maximum permanent elongation change after cooled

GB/T2951

%

%

≤80

≤5

68

-4

Dielectric strength

GB/T1408.1

MV/m

≥30

43*

Volume resistance (20℃)

GB/T1410

Ω.m

≥1.0×1014

3.5×1014*

Gel content

JB/T 10437

%

≥60

60

Typical values were tested on the 1mm sample strip by squeezing film extrusion after mixing compound of A& B (at percentage of 95:5) and be boiled in hot water at 90℃for four hours.

*Especially, these typical values were tested by press moulding sample under the condition of 180±2 ℃, 15min, and pressure over 15Mpa, then boiled in 90℃ water for four hours.

Recommended Processing Technique

1.   Extrusion Equipment

Most extruders for PVC and PE suit for 4214Q.

The recommended equipment and processing technique is as following.

Ratio of length and diameter                    18—25:1

Diameter                                                45—120mm

Ratio of compressing                              1.5—3.5

Ratio of elongation                                  1:1.0—1:1.5

Filtering mesh                                         40/60/40

2.   Extruder processing temperature and other related settings

Temperature Setting:  Specific processing temperature should bebased on different equipment and pressing conditions, reference settings are as following:

Feeding section(℃)

Compression Section(℃)

Measurement Section

(℃)

Die head and Mould

(℃)

150~165

165~175

175~190

190~200


Die head setting:
Squeezing extrusion style, half-tubing extrusion style and tubing extrusion style

Cooling water temperature: Should not beless than 25℃,gradual cooling water tank is recommended.

   

3.   Crosslink

After extrusion and cooling, the cable can be crosslinked by immersed in hot water (90℃) or exposed in low pressure vapour. The time required for crosslink is based on the thickness of the insulation and the coil size, the thicker the insulation and the greater the coil size, the longer the crosslink time required. The crosslink time canbe calculated according to the equation of 4hr/mm for 90℃.


Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Is the toilet wire walk on the ground? Are there any hidden dangers?
The proportion of the cross-sectional area of the cable through the embedded pipe is 20%
Q:What is the difference between "wire" and "cable"?
Simple point, the plotter is generally used to out of the line map, the general is the Academy of Engineering, the Bureau of the use of a CAD map, and some can also be some effect of the general effect of the map, generally suitable for color requirements are not very high, but right Print accuracy requires a high place. Inkjet machine can be divided into indoor and outdoor ink, outdoor irritating smell, for outdoor advertising like the effect of the map, the indoor no irritating smell, the general subway, as well as other indoor advertising are used this out of
Q:What is the current good computer configuration on the market? The price of 4000 yuan or so no more than 4000 assembly parts to write down the price Thank you.
A very practical proposal: to your local talent market, a large job fairs, and the best and your professional relevance, to see, look at what positions, pay how? You can also chat with hr, you will understand.
Q:When pouring concrete is how to put the tube
Line pipe is poured before the concrete is laid on the cloth, fixed on the template or steel, pouring a need to install a class at any time to adjust its position!
Q:Ipad charging display does not support this accessory
Data line problem, it may be the data line to the bad, caused by poor contact. For the sake of the root
Q:Home wiring is a good line or a good line? Talk about the difference
This approach is a lot of the general is to extend the city line, that is, line 220V AC line lengthened, some in Taobao. 2. to extend the low-voltage line, engage in a power plug on the plug, the same set of seats, you can easily do an extension line, when you want to use, docking about it, when you can not close up. This is also on Taobao, when to buy, pay attention to the socket, plug the model to the on.
Q:How are various wire and cable models named?
Cable type a lot, here to give an example: ZRC-YJV22-0.6 / 1KV3 * 25 +2 * 16 This model specification means: C-class flame retardant (ZRC) XLPE insulated (YJ) PVC jacket 22) steel tape armor (0.6 / 1KV) 0.6 / 1 kV (3 * 25) 3 25 square (+ 1 * 16) plus two 16 square copper conductor flame retardant copper core steel tape armored cross-linked poly Ethylene insulated PVC sheathed low voltage electric power.
Q:Fiber optic cable split box, integrated wiring box, cable terminal box, cable transfer box difference
Outdoor fire line must use fire-resistant KVV cable, wear pipe protection.
Q:Is there a difference between PE cable and PE water supply pipe?
Labor costs you can and workers to discuss, and some labor costs are calculated in accordance with square meters, and some are calculated in accordance with the day, the specific or ask the local construction team
Q:What is the difference between a kbg threading pipe and a PVC threading pipe?
May be charging head of the problem, the line may also be a problem. If the warranty can be free for the change.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range