P3 Indoor Full Color Led CMAX-P3
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- -
- Supply Capability:
- 1000000 M2 Per Month m²/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Specifications
1. High brightness 2000nits
2. High Resolution 160000
3. CE ROHS ETL SGS SAA Fcc UL
4. Low power consumption
5. Good Service
Model | HY3 | HY4 | HY5 | HY6 | HY7.62 | HY10 |
LED Type | 3in1 SMD | 3in1 SMD | 3in1 SMD | 3in1 SMD | 3in1 SMD | 3in1 SMD |
Pixel configuration | 1R1G1B | 1R1G1B | 1R1G1B | 1R1G1B | 1R1G1B | 1R1G1B |
LED driving method | 1/16 scan | 1/16 scan | 1/16 scan | 1/8 scan | 1/4 scan | 1/4 scan |
Module Pixels | 64*32(W*H) | 64*32(W*H) | 64*32(W*H) | 32*16(W*H) | 32*16(W*H) | 32*16(W*H) |
Pixel pitch | 3mm | 4mm | 5mm | 6mm | 7.62mm | 10mm |
LED module size(mm) | 192*96*12 | 256*128*12 | 320*160*12 | 192*96*16 | 243.84*121.92*16 | 320*160*16 |
LED board | 4*8 | 3*6 | 2*4 | 4*8 | 2*6 | 2*6 |
Cabinet area | 0.59㎡ | 0.59㎡ | 0.41㎡ | 0.59㎡ | 0.36㎡ | 0.61㎡ |
Cabinet size | 768*768*162 | 768*768*162 | 640*640*162 | 768*768*166 | 487.68*731.52*166 | 640*960*166 |
Net weight | 18Kg | 18Kg | 23Kg | 25Kg | 19Kg | 31Kg |
Max.power consumption | ≤940W/㎡ | ≤980W/㎡ | ≤780W/㎡ | ≤1050W/㎡ | ≤1050W/㎡ | ≤810W/㎡ |
Avg.power consumption | ≤329W/㎡ | ≤343W/㎡ | ≤273W/㎡ | ≤368W/㎡ | ≤368W/㎡ | ≤284W/㎡ |
Hor.viewing angle | 120° | 120° | 140° | 140° | 140° | 140° |
Vert.viewing angle | 120° | 120° | 140° | 140° | 140° | 140° |
Brightness | ≥1200 cd/㎡ | ≥1200 cd/㎡ | ≥1500 cd/㎡ | ≥2000 cd/㎡ | ≥2000 cd/㎡ | ≥1500 cd/㎡ |
Pixel density | 111111/㎡ | 62500/㎡ | 40000/㎡ | 27778/㎡ | 17222/㎡ | 10000/㎡ |
Contrast ratio | 2000:01:00 | 2000:01:00 | 2000:01:00 | 2000:01:00 | 2000:01:00 | 2000:01:00 |
Lifetime (50% brightness) | 100,000 hours | 100,000 hours | 100,000 hours | 100,000 hours | 100,000 hours | 100,000 hours |
Processing | 16 bit | 16 bit | 16 bit | 16 bit | 16 bit | 16 bit |
Colors | 687 billion | 687 billion | 687 billion | 281 trillion | 281 trillion | 281 trillion |
Refresh rate | ≥ 1200 Hz | ≥ 1200 Hz | ≥ 1200 Hz | ≥ 2400 Hz | ≥ 2400 Hz | ≥ 2400 Hz |
Frame rate | 60 fps | |||||
Brightness level | Manually 100 levels, automatically 16 levels. | |||||
- Q:How do I choose the dot pitch of the LED display?
- Uses: Widely used in railway, civil aviation, sports venues, conference halls, highways, squares, large shopping malls, banks, securities markets and a variety of transportation, water conservancy, electricity monitoring and control.
- Q:What is the difference between an LED display and an LCD monitor?
- Notebook LCD screen commonly used is TFT. TFT (Thin Film Transistor) refers to the thin film transistor, each of the liquid crystal pixels are integrated in the pixel behind the thin film transistor to drive, which can be high speed, high brightness, high contrast display screen information is the best One of the LCD color display devices is now the mainstream display device on laptops and desktops.
- Q:Led display support what video format
- Graphic effects display function: with the text to edit, zoom, scroll, animation and other functions. Can display a variety of computer information, graphics, images and two, three-dimensional computer animation, can be superimposed text. Broadcast system with multimedia software, you can flexibly enter and broadcast a variety of information
- Q:LED display how to install it?
- This installation and cantilever installation similar, the same application, the screen body with a cabinet design, suitable for indoor, semi-outdoor screen body.
- Q:LED display applications are what
- Mail, shopping malls and other services in the field of business publicity and information display, advertising media, new products, performances and meetings, exhibitions, LED display large screen as an exhibition organizer to provide one of the important services, indoor large-screen TV applications
- Q:LED display more than the size of the area must be 380v
- General LED screen to reach more than 20 square meters will use more than two power lines, and then some will use three-phase electricity. At the same time and time-sharing power system with the use, so as not to impact on the power grid. The maximum power can take 80 percent of the capacity to leave a margin of 20 percent. Also pay attention to the choice of cable, and lightning protection measures.
- Q:Production of LED display the basic raw materials which ah?
- Circuit board, light-emitting diode, 138,245D, 4953, driver IC, capacitor, resistance, mask, bottom shell, bracket, magnetic column, waterproof glue, waterproof pad, pin, cable, power cord, power supply , Box, steel structure, control system (synchronous receiving card, send card, adapter board; asynchronous card)
- Q:IPS screen and LED screen difference
- LED is the light-emitting diode, so the so-called LED screen is the concept of confusion, in fact, LCD panel with LED as a backlight, but also useful as a backlight CCFL, CCFL is cold cathode fluorescent tube,
- Q:16: 9LED What is the approximate size of the display?
- First determine a length or width size, here to length as an example. If the length is 96 meters, then 96 ÷ 16 = 6 × 9 = 54 meters
- Q:LED display power can not be displayed properly
- LED display power can not be normal display of the phenomenon may be caused by a variety of different reasons, encountered this phenomenon Please note that the following aspects can be used to determine the "failure":
1. Manufacturer Overview |
|
---|---|
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
P3 Indoor Full Color Led CMAX-P3
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- -
- Supply Capability:
- 1000000 M2 Per Month m²/month
OKorder Service Pledge
OKorder Financial Service
Similar products
New products
Hot products
Related keywords