LED Indoor Rental Display CMAX-DI
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- -
- Supply Capability:
- 100000000 M2 Per Month m²/month
OKorder Service Pledge
Quality Product, Order Online Tracking, Timely Delivery
OKorder Financial Service
Credit Rating, Credit Services, Credit Purchasing
You Might Also Like
LED Indoor Rental Display CMAX-DI
DI Series are the lightest high resolution led screens in the market. It's made of aluminum alloy,each panel weight is only 7.5kg indoor / 22kg outdoor. DI and DO can work without fans.
DI Features
Aluminum,super light weight
Fan-less design
Modular structure design,rapid maintenace
Fast locking system
DI Series | DI-3.1 | DI-3.9 | DI-4.8 | DI-5.2 | DI-6.2 | DI-7.8 |
Pixel Pitch | 3.125mm | 3.906mm | 4.8mm | 5.208mm | 6.25mm | 7.81mm |
LED Configuration | SMD2020-N/SMD2020-H | SMD2020-N/SMD2020-H | SMD3528 | SMD3528 | SMD3528 | SMD3528 |
Pixel Density | 102400/㎡ | 65536/㎡ | 43264/㎡ | 36864/㎡ | 25600/㎡ | 16384/㎡ |
Unit Size(mm) | 500(W)x500(H)x63(D) | |||||
Unit Weight | 7.5kg | |||||
Unit Resolution | 160x160 | 128x128 | 104x104 | 96x96 | 80x80 | 64x64 |
Module Size(mm) | 250(W)x250(H) | |||||
Module Resolution | 80(W)x80(H) | 64(W)x64(H) | 52(W)x52(H) | 48(W)x48(H) | 40(W)x40(H) | 32(W)x32(H) |
Scan Mode | 1/16 | 1/16 | 1/13 | 1/8 | 1/8 | 1/8 |
Brightness(cd/sqm) | ≥1000/≥2400 | ≥1000/≥2400 | ≥2400 | ≥2400 | ≥2400 | ≥2000 |
Driver IC | MBI5024/MBI5152 | MBI5024/MBI5152 | MBI5024/MBI5152 | MBI5024/MBI5041/MBI5151 | MBI5024/MBI5041/MBI5151 | MBI5024/MBI5041/MBI5151 |
Refresh Frequency | ≥600Hz/≥2000Hz | ≥600Hz/≥2000Hz | ≥600Hz/≥2000Hz | ≥600Hz/≥1000Hz/≥2000Hz | ≥600Hz/≥1000Hz/≥2000Hz | ≥600Hz/≥1000Hz/≥2000Hz |
Power Consumption(max/avg)(W/pc) | 210/70 | 210/70 | 210/70 | 210/70 | 210/70 | 180/60 |
Gray Scale | ≥12bit/≥16bit | ≥12bit/≥16bit | ≥12bit/≥14bit | ≥12bit/≥14bit/≥16bit | ≥12bit/≥14bit/≥16bit | ≥12bit/≥14bit/≥16bit |
Viewing Angle | H140°/V140° | |||||
IP Level(front/rear) | IP31/IP31 | |||||
Control System | NOVA/DBSTAR/LINSN | |||||
Working Temperature | -30°C - +50°C | |||||
Operating Humidity | 10-90% RH |
- Q: LED display how to install it?
- 1) single column installation: for small screen applications; 2) double column installation: suitable for large-screen applications; 3) closed maintenance channel: applicable to the use of the following columns: 1) single column installation: In the simple box; 4) open maintenance channel: for the standard box.
- Q: LED display power supply how to configure how many units with the plate is calculated.
- Upstairs are said that the P10, if you do not use the P10 it I tell you how to calculate the power of a board. Generally you take a lamp beads 0.02A to count, a board on the total lamp beads * 0.02, if the board is 4 sweep with the band / 4,8 sweep of the 8, the static is not removed to get a board of power
- Q: How to identify the quality of led display quality
- Control card is basically 99% of the led display manufacturers are outsourced, the industry is better that is the celebration, superstar, de Puda, Nova, Carter these are used in full-color display more Some, relatively stable stability is better.
- Q: LED outdoor display which part of the composition
- Outdoor LED display is usually in the form of outdoor media. The main forms include road LED display, LED electronic display, LED full color screen, LED screen, balloon, airship, compartment, large inflatable model.
- Q: LED display a board dark light how is it?
- Visual power cable, unit board between the 26P cable and power module indicator light is normal. The following are the same as the "
- Q: LED electronic display and P have anything to do
- P generally represents the pixel pitch, and P followed by the value of the two mainly refers to the distance between the pixels, usually called the point spacing. And the smaller the value of this point spacing, the higher the unit pixel, the more clear the display screen.
- Q: Comparison between LED display and DLP splicing
- LED display is an advanced digital information products, it successfully combines the computer technology, network communication technology, image processing technology, embedded control technology, with a flexible display area and resolution (modular can be arbitrarily assembled),
- Q: LED display more than the size of the area must be 380v
- General LED screen to reach more than 20 square meters will use more than two power lines, and then some will use three-phase electricity. At the same time and time-sharing power system with the use, so as not to impact on the power grid. The maximum power can take 80 percent of the capacity to leave a margin of 20 percent. Also pay attention to the choice of cable, and lightning protection measures.
- Q: IPS screen and LED screen difference
- LED is the backlight, longer life, lower cost, with TN screen you slightly higher performance, LED performance is good, high dynamic contrast. The disadvantage is too bright, a little hurt eyes. Now the mainstream are used LED screen, short response time, suitable for playing games.
- Q: Led display point density is what it means
- LED is the display, like your home TV case above the red light, LED LCD TV even more clear, but also expensive, LED screen is a small lamp composed of the screen, the cost is high, Generally a lot of roadside that kind of big screen is LED
Send your message to us
LED Indoor Rental Display CMAX-DI
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- -
- Supply Capability:
- 100000000 M2 Per Month m²/month
OKorder Service Pledge
Quality Product, Order Online Tracking, Timely Delivery
OKorder Financial Service
Credit Rating, Credit Services, Credit Purchasing
Similar products
Hot products
Hot Searches
Related keywords