Hybrid Solar Inverter GS3600S-UK
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 10 unit
- Supply Capability:
- 100 unit/month
OKorder Service Pledge
Quality Product, Order Online Tracking, Timely Delivery
OKorder Financial Service
Credit Rating, Credit Services, Credit Purchasing
You Might Also Like
GW3600S-UK
The SS series is widely and flexibly used in domestic units because of its wide range of voltage and current inputs. It features very high conversion efficiency and reliability. SS series provides long-term and stable generating benefits. The powerful, intelligent, user friendly interface and sleek stylish design make it most suitable for domestic applications.
DC Input Data | Max.PV-generator power[W] | 4200 |
Max.DC voltage[V] | 580 | |
MPPT voltage range[V] | 125~550 | |
Turn on DC voltage[V] | 125 | |
Max.DC work current[A] | 20 | |
Number of inputs/MPP trackers | 3/1 | |
DC connector | MC IV Connector | |
Self-energy consumption[W] | <5< td=""> | |
AC Output Data | Nominal AC power[W] | 3600 |
Max.AC power[W] | 4000 | |
Max.output current[A] | 16 | |
Nominal output voltage range | G83/1; VDE0126-1-1/AI | |
AC grid frequency | G83/1; VDE0126-1-1/A1 | |
THDi | 〈1% | |
Power factor | ~1 | |
AC connection | Single phase with clamps | |
Efficiency | Max.efficiency | 97.6% |
European efficiency | >97.4% | |
MPPT adaptation efficiency | >99.5% | |
Safty Equipment | Leakage current monitoring unit | Integrated |
DC switch disconnector | Optional | |
Islanding protection | AFD | |
Grid monitoring | G83/1; VDE0126-1-1/A1 | |
Normative Reference | EMC compliance | EN 61000-6-1,EN 61000-6-2, EN 61000-6-3,EN 61000-6-4 |
Safety compliance | According to IEC 62109-1 | |
General Data | Dimensions(W*H*D) [mm] | 390*417*142 |
Net weight [kg] | 18 | |
Housing | For outdoor and indoor | |
Mounting information | Wall bracket | |
Operating temperature range | -20~60℃(up 45℃ derating) | |
Relative humidity | 0 ~ 95% | |
Site altitude[m] | 2000 | |
IP proection class | IP65 | |
Topology | Transformerless | |
Cooling | Nature convection | |
Noise level[dB] | 〈25 | |
Display | 4" LCD | |
Communication | USB2.0;RS485(Wireless/Bluetooth optional) | |
Standard warranty[years] | 5/10/15/20/25 (optional) |
- Q: Can a solar inverter be used in grid-tied systems?
- Yes, a solar inverter can be used in grid-tied systems. In fact, a solar inverter is an essential component of a grid-tied system as it converts the direct current (DC) produced by the solar panels into alternating current (AC) that can be fed into the electrical grid. This allows for the efficient utilization of solar energy and enables homeowners or businesses to offset their electricity consumption with solar power, potentially even earning credits for excess energy produced.
- Q: Can a solar inverter be used in regions with high levels of lightning activity?
- Yes, a solar inverter can be used in regions with high levels of lightning activity. However, it is important to install appropriate lightning protection measures to ensure the safety and functionality of the solar inverter system. This can include surge protection devices and grounding systems to mitigate potential damage caused by lightning strikes.
- Q: What is the role of a galvanic isolation transformer in a solar inverter?
- The role of a galvanic isolation transformer in a solar inverter is to provide electrical isolation between the solar panels and the grid, ensuring the safety of the system. It prevents any direct electrical connection between the high voltage DC side and the low voltage AC side, while allowing the transfer of power between them. This isolation protects both the system components and the users from potential electrical hazards, such as short circuits or ground faults. Additionally, the galvanic isolation transformer helps reduce noise and interference in the system, enhancing the overall performance and reliability of the solar inverter.
- Q: How does a solar inverter handle fluctuations in solar panel output?
- A solar inverter handles fluctuations in solar panel output by continuously monitoring the voltage and current levels of the panels. It adjusts the power conversion process to match the varying output and optimize the energy conversion. This allows it to maintain a stable and consistent output, even when the solar panel's output fluctuates due to factors like shading, cloud cover, or changes in sunlight intensity.
- Q: How does the input voltage rating affect the performance of a solar inverter?
- The input voltage rating is a critical factor in determining the performance of a solar inverter. The inverter's ability to convert the direct current (DC) generated by solar panels into alternating current (AC) for use in homes or businesses depends on the input voltage rating. If the input voltage rating of the inverter is not compatible with the voltage produced by the solar panels, the inverter may not function properly or may even be damaged. Thus, selecting an inverter with the correct input voltage rating is essential for optimal performance and longevity of a solar power system.
- Q: How does a solar inverter handle islanding detection and prevention?
- A solar inverter handles islanding detection and prevention by constantly monitoring the grid and its own power output. If it detects a loss of grid connectivity, it initiates a process called anti-islanding, where it stops supplying power to the grid to prevent the formation of an island. The inverter accomplishes this by monitoring the frequency and voltage levels of the grid, and if it detects a deviation beyond a certain threshold, it disconnects from the grid within a specific timeframe. This ensures that the inverter does not continue to supply power to an isolated grid, which could pose safety risks to utility workers and damage electrical equipment.
- Q: How does a solar inverter convert DC to AC power?
- A solar inverter converts DC (direct current) power generated by solar panels into AC (alternating current) power that is compatible with household and grid electricity. It does this by utilizing electronic components such as transistors and capacitors to convert the fixed voltage and current of DC power into a fluctuating form that resembles the waveform of AC power. The inverter then boosts the voltage to the desired level and synchronizes the frequency of the AC power with the grid's frequency before feeding it into the electrical system.
- Q: How does a solar inverter handle shade on solar panels?
- A solar inverter handles shade on solar panels by utilizing Maximum Power Point Tracking (MPPT) technology. This technology continuously monitors the solar panels' output and adjusts the voltage and current to maximize energy production. When shade falls on a panel, the MPPT algorithm identifies the affected panel and dynamically adjusts its output to minimize the impact of shade on the overall system performance. This ensures that even partially shaded panels can still contribute to the overall energy generation of the solar installation.
- Q: Are all solar inverters compatible with all solar panels?
- No, not all solar inverters are compatible with all solar panels. The compatibility between inverters and panels depends on factors such as voltage, power output, and technology. It is important to ensure that the inverter and solar panels are compatible to optimize the performance and efficiency of the solar energy system.
- Q: What is the role of a solar inverter in preventing electrical hazards?
- The role of a solar inverter in preventing electrical hazards is to convert the direct current (DC) power generated by solar panels into alternating current (AC) power that can be used in homes and businesses. By regulating the voltage and frequency of the electricity, the inverter ensures that the power is safe and compatible with the electrical grid. Additionally, solar inverters have built-in safety features such as ground fault protection and rapid shutdown mechanisms, which help prevent electrical hazards such as fires, shocks, and damage to the system.
Send your message to us
Hybrid Solar Inverter GS3600S-UK
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 10 unit
- Supply Capability:
- 100 unit/month
OKorder Service Pledge
Quality Product, Order Online Tracking, Timely Delivery
OKorder Financial Service
Credit Rating, Credit Services, Credit Purchasing
Similar products
Hot products
Hot Searches
Related keywords