Fire Resistant Flexible Aluminum Duct
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 100 m
- Supply Capability:
- -
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Semirigid Insulated Aluminum Flexible Duct Fire Resistant Flexible Aluminum Duct
1.Structure of Fire Resistant Flexible Aluminum Duct:
Flexible air ducts are typically made of flexible plastic over a metal wire coil to shape a tube. And they have a variety of configurations. Flexible ducts are very convenient for attaching air outlets to the rigid ductwork. It is commonly attached with long zip ties or metal band claps. Besides, flexible ducts can tolerate moderate negative pressures.
2.Main Features of Fire Resistant Flexible Aluminum Duct:
-Applied in air conditioning/ventilation systems
-Tear and puncture resistant
-Corrosion resistant
-High flexibility
-Convenient installation
-No toxic gas emission
3. Fire Resistant Flexible Aluminum Duct Images
4. Fire Resistant Flexible Aluminum Duct Specification
Insulated Flexible Duct
Structure: 1 layer of Aluminum Foil+1 layer PET film+insulated glass wool
Outer jacket: 1 layer of Aluminum Foil
Glass Wool Density: 16kg/m3; Thickness: 25mm
Insulated Acoustic Flexible Duct
Structure: 1 layer of Aluminum Foil +1 layer PET film+ insulated glass wool
Outer jacket: 1 layer of Aluminum Foil + 1 layer of PET film
Glass Wool Density: 32kg/m3; Thickness: 25mm
Specification
Type 1
Material | Aluminum foil |
Structure | Inner pipe is made of aluminum foil and inside spiral structure is hold by high tensile steel wire. |
Application | Suitable for medium-low air speed |
Technical Parameter
Size | 4”-16” |
Standard Length | 10m |
Maximum Air Speed | 20m/s |
Maximum Heat Resistance | -20℃-150℃ |
Maximum Pressure | 250mmWG |
Type 2
Material | Aluminum foil 25mm thickness ,16kg/m3 glass wool. |
Structure | Inner pipe is made of aluminum foil and inside spiral structure is hold by high tensile steel wire. Insulating layer is covered by 25mm thickness ,16kg/m3 glass wool. Outside layer: Reinforced aluminum foil; Inside layer: Glass fiber mesh |
Application | Suitable for medium-low air speed and low temperature difference. |
Technical Parameter
Size | 4”-5”, 6”-12”, 14”-16” |
Standard Length | 7m, 10m |
Maximum Air Speed | 20m/s |
Maximum Heat Resistance | -20℃-150℃ |
Maximum Pressure | 250mmWG |
Type 3
Material | ·Aluminum foil · 25mm thickness ,24kg/m3 glass wool. |
Structure | · Inner pipe is made of aluminum foil and inside spiral structure is hold by high tensile steel wire. · Insulating layer is covered by 25mm thickness ,24kg/m3 glass wool. · Outside layer: Reinforced aluminum foil; Inside layer: Glass fiber mesh |
Application | Suitable for medium-low air speed and large temperature difference. |
Technical Parameter
Size | 6”-12” |
Standard Length | 7m |
Maximum Air Speed | 20m/s |
Maximum Heat Resistance | -20℃-150℃ |
Maximum Pressure | 250mmWG |
5.FAQ
We have organized several common questions for our clients,may help you sincerely:
1.How long for the delivery time?
Delivery time: 10-30 days, it depends on the ordered quantity.
2.What’s the usage?
Practicality: suitable for the densely-populated area(such as school, supermarket, office, stadium, theater, factory.),high requirement of the environment area, such as hospital, laboratory, howff, bus, train, broadcasting studio. main usage: 1) Cold, hot water supply facilities for public buildings 2) Food, chemical, electronic industrial pipeline networks such as pipeline networks for transporting all kinds of corrosive liquid 3) Drinking water production system pipeline networks such as pure water and mineral water 4) Air conditioning facility pipeline 5) Compressed gas pipeline networks for industry 6) Pipeline network for swimming pool 7) Pipeline network for solar energy facility 8) Agriculture and garden production Additional information
③How you control the quality?
During the production of fiberglass insulation, material is sampled at a number of locations in the process to maintain quality.
- Q: Such as the problem, and now air-conditioning technology is mature, the market a lot of air conditioning are cold and warm, and I would like to be able to put my home that the end of the century loaded Mitsubishi air conditioning (split single cold) into a cold Before the conversion of ordinary TV to the remote control, that air conditioning can be modified? How much does it cost? Where is this technology? More
- Air conditioning heating than the cooling power consumption, power consumption and ambient temperature and set the temperature has a great relationship, the general cooling 1 hour 1-2 degrees, heating if the auxiliary heating about 2-3 degrees. If you want to save the appropriate temperature can be set higher, the general and the ambient temperature difference of about 5 degrees people feel more comfortable, shut off undesirable, not reach the purpose of saving.
- Q: If I feel the room cool off, one hour hot and open an hour this will be more expensive? More
- Common scaffold brace is the U-type care, "construction of fasteners steel scaffolding safety technical regulations" (JGJ Gong Gong Duo Ji-tao pan Revenge two 130-2011) provides "adjustable support bearing capacity design value is not Should be less than 40kN, the support plate thickness should not be less than 5mm ", the general calculation using 30kN.
- Q: Air to water heater host and air conditioning host is not the same
- You can try asphalt! Is the kind of paving the way! Very useful!
- Q: Air conditioning ventilation when the sound is a big reason
- No matter, it is best to cut the distance between the material and the roof, like an arbor. Otherwise it is not foam board with it
- Q: Gree air conditioning 50 heating and cooling mechanism heat when the host cooling network is how the matter
- Can be small, according to your roof to do what material.
- Q: What is the whole heat exchange fresh air ventilator?
- Depends on the main control panel is not cold and warm, single cold common motherboard. Only a generic motherboard can be changed. In the single cold air-conditioning on the outdoor machine to install the appropriate specifications of the four-way valve, adjust the amount of refrigerant to the appropriate level can be.
- Q: The installation method of ordinary air conditioner. The more detailed the better. Please thank you all
- 2.1.23 step distance liftheight the distance between the upper and lower horizontal axis of the axis of each other. 2.1.24 pole vertical (cross) distance longitudinal spacingofuprighttube Scaffolding vertical distance between adjacent rods. 2.1.25 Vertical distance transversespacingofuprighttube Scaffolding Horizontal distance between adjacent vertical rods, single row scaffolding for the outside pole axis to the wall distance.
- Q: Ventilation is very good, why still have to install fresh air system
- You are a single raft toilet wipes Pie Tanzhuang open card would like to confirm what? Contract notarization or. The The If it is contract notarized, generally notary value of 0.25% -0.3%
- Q: In the design, the building structure and the hydropower are generally designed by the Architectural Design Institute. The air conditioning ventilation is based on the design of the room. Or first air conditioning ventilation? More
- Polystyrene should not be polycyclic aromatic. Polycyclic aromatic groups generally refer to aromatic groups when multiple benzene rings are used. Not all of the hydrocarbon chemical products are carcinogenic, and our bodies are producing hydrocarbon compounds all the time. Polystyrene carcinogenicity is small. General benzene ring on the more substituents, the toxicity is relatively small, such as toluene is less than the toxicity of benzene. Of course, there are many compounds with benzene ring, so there are a lot of scholars to study with our body creatures do not meet the quality of raw materials to do the polymer, such as lactic acid production of polylactic acid, but the current Can be put into use much.
- Q: HVAC Heating: What are the main components of the air distribution system?
- (HS Code) Yes, the tax rebate is 13% (April . 2009 latest data). Floor of the board of the tax number is, the tax rebate is 9% (June . 2009 the latest data), floor board is the inspection of goods, exports need to be checked. There is nothing to understand where to add me MSN:
Send your message to us
Fire Resistant Flexible Aluminum Duct
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 100 m
- Supply Capability:
- -
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords