Ethernet Switch Series JT-94000
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 5 Boxes pc
- Supply Capability:
- 1000 Boxes per Month pc/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Features
Provides flexibility of 5 or 8 Ethernet ports
Supports 10/100Mbps-Full/Half-duplex, Auto-Negotiation, Auto-MDI/MDIX
Redundant power inputs(12 - 48VDC) with Terminal Block and
DC Jack (12VDC)
Alarms for power and port failure by relay output
-40°C to 75°C (-40°F to 167°F) operating temperature range, tested for functional operation @ -40°C to 85°C (-40°F to 185°F)
Provides DIN-rail or panel mounting
Complies with NEMA TS1 & TS2 Environmental requirements for Traffic control equipment
Complies with IEC61000-6-2 EMC Generic standard immunity for Industrial environment
UL1604 Class I Division 2 Classified for use in hazardous locations.
Technology
Standards
IEEE802.3 10BASE-T, IEEE802.3u 100BASETX/100BASE-FX,IEEE802.3x
Forward and Filtering Rate
14,880pps for 10Mbps
148,810pps for 100Mbps
Packet Buffer Memory
768K bits
- Q: How many power illuminator can 5Kva 36V transformer drive?
- Transformer (Transformer) is a device that uses the principle of electromagnetic induction to change AC voltage. The main components are primary coil, secondary coil and iron core (magnetic core). The main functions are voltage conversion, current conversion, impedance transformation, isolation, voltage stabilization (magnetic saturation transformer) and so on. According to use can be divided into: power transformers and special transformers (electric furnace transformer, rectifier transformer, power frequency test transformer, voltage regulator, mine, variable audio transformers, intermediate frequency transformers, high frequency transformer, transformer, instrument transformer, the impact of electronic transformer, reactor, transformer etc.). Circuit symbols are often used as the beginning of numbers. Examples: T01, T201, T, etc..
- Q: Why should lighting transformers be used in factories and mines?
- In some factories and mines (such as power plants), in order to supply power reliability, the power system is grounded in a three-phase, ungrounded, or neutral manner. In this way, the transformer must be connected to a neutral grounding type with a special transformer to supply power to the lighting.
- Q: 1000 square meters low voltage.36 volts lighting power supply with multiple transformers and wires
- You must know the quantity and power of the lamp to determine the transformer
- Q: Why is the two side of the lighting transformer grounded?
- In the three-phase transformer, the neutral point of the three-phase transformer and the metal case are always reliably connected, and the utility model has the advantages of reliable grounding, both working grounding, protection and earthing, and protection of personal safety and equipment safety.
- Q: Why is elevator lighting transformer installed?
- Is that the kind of 220V change 36V ah, if it is that kind of thing, I think it should be for security reasons. After all, 36V is a safe voltage. The damage to humans is slightly smaller than that of 220V.
- Q: Is the substation separate from the power and illumination transformer?
- There is only bus in the substation, and the station is connected with the transformer from the bus. If there is no electricity even in the bus, then the substation should not be considered active.
- Q: 3 24V100W lights, I need to use a large capacity transformer (220V change 24V)?
- Pure resistive load, the power factor is 1.3 *100W=300W, is required for the capacity of the transformer.
- Q: Does the lighting work properly? Doesn't that power equipment start voltage unstable?
- As long as the capacity of the transformer is enough, the voltage fluctuation of the line will be sure to occur when the high power equipment is started. Such fluctuations do not have much impact on the lighting.
- Q: Why can't autotransformer be used as transformer for safety lighting?
- The main and auxiliary coils of the autotransformer have common parts. Once the short-circuit is made, the lighting circuit is directly connected with the high voltage circuit, which is very dangerous
- Q: Please tell me how to calculate the transformer in the lighting circuit of elevator shaft in building electrical design
- Because of the brightness of the 36V safety voltage lamp brightness in the overhaul work is not enough, so now the well lighting design should not be 36V, and replaced by 220V, and only need to add a leakage protector on it.
1. Manufacturer Overview
Location | Taiwan,Taiwan |
Year Established | 2003 |
Annual Output Value | US$1 Million - US$2.5 Million |
Main Markets | North America; South America; Eastern Europe; Southeast Asia; Africa; Oceania; Mid East; Eastern Asia; Western Europe; Northern Europe |
Company Certifications |
2. Manufacturer Certificates
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability
a) Trade Capacity | |
Nearest Port | |
Export Percentage | 91% - 100% |
No.of Employees in Trade Department | |
Language Spoken: | |
b) Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | OEM Service Offered Design Service Offered Buyer Label Offered |
Product Price Range |
Send your message to us
Ethernet Switch Series JT-94000
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 5 Boxes pc
- Supply Capability:
- 1000 Boxes per Month pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords